Skip to content
SafetyRecord logoSafetyRecord
A M T INC.
$2,865
penalties
16
viol.
4
insp.

A M T INC.

75 CHESTNUT STREET, SHARON SPRINGS, NY 13459

Inspections
4
Aug 1996 to Jun 2000 · 1 safety, 3 health
Violations
16
across 4 inspections
Penalties on record
$2,865
latest amounts in DOL records
By classification
Serious 12Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 15, 2000Complaint (B) · Complete scope, Health#303369243$4553 viol.

Inspection #303369243

Dates

Opened
Jun 15, 2000
Closing Conference Date
Aug 9, 2000
Closed
Nov 9, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$700
Penalties on Record
$455
Site Address
75 Chestnut Street, Sharon Springs, NY 13459
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling12 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)100mg/m³
Beryllium and Beryllium Compounds (as Be)100 - 0.0606mg/m³
Chromium, Metal and Insoluble Salts100 - 0.1141mg/m³
Cobalt, Metal, Dust and Fume (as Co)100 - 0.0111mg/m³
Copper Fume (as Cu)100 - 2.1288mg/m³
Gravimetric DeterminationQC20 - 0.8605mg/m³
Iron Oxide Fume100 - 1.4373mg/m³
Lead, Inorganic (as Pb)100mg/m³
Manganese Fume (as Mn)100 - 0.0096mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)100 - 0.0011mg/m³
Nickel, Metal and Insoluble compounds (as Ni)100 - 0.0677mg/m³
Sample WeightQC20 - 0.28mg
Vanadium fume (as V2O5)100mg/m³
Zinc Oxide Fume100 - 0.0182mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.132
General requirements
OSHA citation code: 19100132 A
Serious11$700$455Sep 10, 2000--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Other15$0$0Sep 25, 2000--
020021910.134
Respiratory Protection
OSHA citation code: 19100134 F02
Other15$0$0Sep 25, 2000--
Sep 3, 1997Monitoring (D) · Partial scope, Health#109051490$00 viol.

Inspection #109051490

Dates

Opened
Sep 3, 1997
Closing Conference Date
Oct 28, 1997
Closed
Oct 28, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
75 Chestnut Street, Sharon Springs, NY 13459
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Sep 19, 1996Referral (C) · Partial scope, Health#109051904$6255 viol.

Inspection #109051904

Dates

Opened
Sep 19, 1996
Closing Conference Date
Oct 15, 1996
Closed
Dec 4, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20
Related Activity
1 referral

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$1,150
Penalties on Record
$625
Site Address
75 Chestnut Street, Sharon Springs, NY 13459
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling15 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Aluminum (as Al), Metal (Total Dust)31.203 - 6.564mg/m³
Antimony and Compounds (as Sb)30
Beryllium and Beryllium Compounds (as Be)30
Chromium, Metal and Insoluble Salts30.0043 - 0.04
Cobalt, Metal, Dust and Fume (as Co)30
Copper Fume (as Cu)30.0026 - 0.0049
Gravimetric DeterminationQC31.203 - 6.564mg/m³
Iron Oxide Fume30.129 - 1.7864
Lead, Inorganic (as Pb)30
Manganese Fume (as Mn)30.000719 - 0.0089
Molybdenum (as Mo), Insoluble Compounds (Total Dust)30 - 0.0034
Nickel, Metal and Insoluble compounds (as Ni)30.0032 - 0.0098
Silica, Crystalline Cristobalite, Respirable Dust30 - 5.5%
Silica, Crystalline Quartz (Respirable Fraction)30 - 6.9%
Vanadium fume (as V2O5)30
Zinc Oxide Fume30

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious16$525$525Dec 20, 1996--
02001A1910.134
Respiratory Protection
OSHA citation code: 19100134 B01
Serious11$625$100Jan 31, 1997--
02001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E05
Serious11$0$0Jan 31, 1997--
02001C1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious11$0$0Dec 10, 1997--
02001D1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Dec 10, 1997--
Aug 12, 1996Planned (H) · Complete scope, Safety#300522810$1,7858 viol.

Inspection #300522810

Dates

Opened
Aug 12, 1996
Closing Conference Date
Aug 14, 1996
Closed
Sep 30, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
8
Violation Types
6 serious, 2 other-than-serious
Initial Penalties
$2,550
Penalties on Record
$1,785
Site Address
75 Chestnut Street, Sharon Springs, NY 13459
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
OSHA citation code: 19100106 E06 I
Serious1-$450$315Sep 13, 1996--
01001B1910.106
OSHA citation code: 19100106 E06 II
Serious15$0$0Sep 13, 1996--
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious120$600$420Oct 6, 1996--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious15$450$315Oct 6, 1996--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious24$450$315Sep 6, 1996--
010051910.303
OSHA citation code: 19100303 G02 I
Serious15$600$420Sep 6, 1996--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C04
Other15$0$0Sep 6, 1996--
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G02
Other120$0$0Oct 6, 1996--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.134Respiratory Protection4 citations · $100
1910.1062 citations · $315
1910.1000Air Contaminants2 citations · $0

Chemical exposure sampling

Samples
172
Substances
17
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in SHARON SPRINGS, NY

All employers in SHARON SPRINGS →