Skip to content
SafetyRecord logoSafetyRecord
A.F.W. FOUNDRY, INC.
$48,885
penalties
92
viol.
13
insp.

A.F.W. FOUNDRY, INC.

21020 W. GOOD HOPE ROAD, Lannon, WI 53046

Inspections
13
May 1986 to Mar 2022 · 2 safety, 11 health
Violations
92
across 13 inspections
Penalties on record
$48,885
latest amounts in DOL records
By classification
Serious 70Willful 0Repeat 2Other 20

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 29, 2022Complaint (B) · Partial scope, Health#345864078$25,00017 viol.

Inspection #345864078

Dates

Opened
Mar 29, 2022
Closing Conference Date
Aug 31, 2022
Contested
Sep 27, 2022
Final Order
Jan 20, 2023
Closed
Mar 6, 2025

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
63
Related Activity
1 complaint

Violations and Penalties

Total Violations
17
Violation Types
16 serious, 1 other-than-serious
Initial Penalties
$59,096
Penalties on Record
$25,000
Site Address
21020 Good Hope Road, Lannon, WI 53046
Industry
332999 All Other Miscellaneous Fabricated Metal Product Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.22
OSHA citation code: 19100022 A03
Serious33$10,151$5,000Sep 15, 2022Sep 27, 2022Jan 20, 2023
01002A1910.132
General requirements
OSHA citation code: 19100132 D01 I
Serious22$10,151$5,000Sep 9, 2022Sep 27, 2022Jan 20, 2023
01002B1910.138
Hand Protection
OSHA citation code: 19100138 A
Serious22$0$0Sep 9, 2022Sep 27, 2022Jan 20, 2023
01003A1910.1053
Respirable Crystalline Silica
OSHA citation code: 19101053 C
Serious22$10,151$10,000Mar 7, 2023Sep 27, 2022Jan 20, 2023
01003B1910.1053
Respirable Crystalline Silica
OSHA citation code: 19101053 F01
Serious220$0$0Mar 7, 2023Sep 27, 2022Jan 20, 2023

Showing the 5 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Mar 28, 2012Referral (C) · Complete scope, Health#332835024$1,7504 viol.

Inspection #332835024

Dates

Opened
Mar 28, 2012
Closing Conference Date
May 16, 2012
Final Order
Jul 20, 2012
Closed
Jul 29, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
69
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
1 serious, 3 other-than-serious
Initial Penalties
$3,500
Penalties on Record
$1,750
Site Address
21020 W. Good Hope Rd., Lannon, WI 53046
Industry
331528

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.95
Occupational Noise Exposure
OSHA citation code: 19100095 C01
Serious515$3,500$1,750Aug 15, 2012-Jul 20, 2012
020011910.37
OSHA citation code: 19100037 A03
Other15$0$0-Jul 20, 2012
020021910.134
Respiratory Protection
OSHA citation code: 19100134 E01
Other11$0$0Jul 25, 2012-Jul 20, 2012
020031910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Other15$0$0Jul 25, 2012-Jul 20, 2012
Mar 20, 2012Complaint (B) · Partial scope, Safety#332818582$5,7506 viol.

Inspection #332818582

Dates

Opened
Mar 20, 2012
Closing Conference Date
Apr 19, 2012
Final Order
Jul 20, 2012
Closed
Jul 17, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
69
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$11,900
Penalties on Record
$5,750
Site Address
21020 W. Good Hope Rd., Lannon, WI 53046
Industry
331528

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
OSHA citation code: 19100023 A08
Serious120$4,900$2,250Jul 18, 2012-Jul 20, 2012
01001B1910.23
OSHA citation code: 19100023 C03
Serious120$0$0Jul 18, 2012-Jul 20, 2012
01001C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious112$0$0-Jul 20, 2012
01002A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious120$3,500$1,750-Jul 20, 2012
01002B1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C04 I
Serious120$0$0-Jul 20, 2012

Showing the 5 violations listed first by citation identifier. This inspection has 6 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Oct 27, 2009Monitoring (D) · Partial scope, Health#313523896$00 viol.

Inspection #313523896

Dates

Opened
Oct 27, 2009
Closing Conference Date
Dec 16, 2009
Closed
Jan 6, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
21020 W. Good Hope Road, Lannon, WI 53046
Industry
331528

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Chemical Exposure Sampling2 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC50.4068 - 0.8667mg/m³
Particulates not otherwise regulated (Respirable Fraction)50.4068 - 0.8667mg/m³
Sample WeightQC50.313 - 0.663mg
Silica, Crystalline Quartz (Respirable Fraction)58.5 - 16%
Jan 6, 2009Follow-Up (F) · Partial scope, Health#311402291$7502 viol.

Inspection #311402291

Dates

Opened
Jan 6, 2009
Closing Conference Date
Mar 30, 2009
Closed
Dec 3, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,500
Penalties on Record
$750
Site Address
21020 W. Good Hope Road, Lannon, WI 53046
Industry
331528

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC41.0332 - 1.6192mg/m³
Sample WeightQC40.754 - 1.329mg
Silica, Crystalline Quartz (Respirable Fraction)47.7 - 13%

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1000
Air Contaminants
OSHA citation code: 19101000 C
Serious11$1,500$750Nov 30, 2010--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious11$0$0Nov 30, 2010--
Jan 15, 2008Complaint (B) · Partial scope, Health#311397137$6004 viol.

Inspection #311397137

Dates

Opened
Jan 15, 2008
Closing Conference Date
Mar 17, 2008
Closed
Dec 3, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
3 serious, 1 other-than-serious
Initial Penalties
$1,225
Penalties on Record
$600
Site Address
21020 W. Good Hope Road, Lannon, WI 53046
Industry
331528

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Gravimetric DeterminationQC70.1018 - 1.4mg/m³
Sample WeightQC70.068 - 1.123mg
Silica, Crystalline Quartz (Respirable Fraction)70 - 13%

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious12$1,225$600Apr 2, 2008--
01001B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious12$0$0Aug 7, 2008--
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious12$0$0May 30, 2008--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other12$0$0Apr 1, 2008--
Aug 3, 1994Referral (C) · Partial scope, Health#122041858$6,0004 viol.

Inspection #122041858

Dates

Opened
Aug 3, 1994
Closing Conference Date
Aug 17, 1994
Closed
Oct 25, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60
Related Activity
1 referral

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 1 repeat, 1 other-than-serious
Initial Penalties
$9,600
Penalties on Record
$6,000
Site Address
21020 W. Good Hope Road, Lannon, WI 53046
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling3 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Copper Dusts and Mists (as Cu)60.0027 - 0.1mg/m³
Copper Fume (as Cu)40.0048 - 0.036mg/m³
Lead, Inorganic (as Pb)100 - 0.012mg/m³

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A02
Serious11$2,100$2,000Sep 26, 1994--
01001B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious11$0$0Sep 26, 1994--
020011910.1025
Lead
OSHA citation code: 19101025 J02 IC
Repeat44$7,500$4,000Sep 14, 1994--
030011904.2
OSHA citation code: 19040002 A
Other160$0$0Sep 19, 1994--
Dec 14, 1992Follow-Up (F) · Partial scope, Health#122033889$1,2253 viol.

Inspection #122033889

Dates

Opened
Dec 14, 1992
Closing Conference Date
Jan 9, 1993
Closed
Mar 10, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,225
Penalties on Record
$1,225
Site Address
21020 W. Good Hope Road, Lannon, WI 53046
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Beryllium and Beryllium Compounds (as Be)30mg/m³
Cadmium Fume (as Cd)40mg/m³
Chromium, Metal and Insoluble Salts40 - 0.0075mg/m³
Cobalt, Metal, Dust and Fume (as Co)40 - 0.0073mg/m³
Copper Fume (as Cu)40 - 0.1521mg/m³
Iron Oxide Fume40 - 0.5157mg/m³
Lead, Inorganic (as Pb)40 - 0.0227mg/m³
Manganese Fume (as Mn)40 - 0.0045mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40 - 0.0074mg/m³
Vanadium fume (as V2O5)40 - 0.0081mg/m³
Zinc Oxide Fume40 - 0.2129mg/m³

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious22$700$700Jan 19, 1993--
01001B1910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious11$0$0Jan 4, 1993--
020011910.1025
Lead
OSHA citation code: 19101025 J02 IB
Serious22$525$525Mar 1, 1993--
May 17, 1991Complaint (B) · Partial scope, Health#102346509$3,5009 viol.

Inspection #102346509

Dates

Opened
May 17, 1991
Closing Conference Date
Nov 13, 1991
Closed
Feb 26, 1993

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50
Related Activity
1 complaint

Violations and Penalties

Total Violations
9
Violation Types
6 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$5,850
Penalties on Record
$3,500
Site Address
21020 W. Good Hope Road, Lannon, WI 53046
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Silica, Crystalline Quartz (Respirable Fraction)50 - 8%

Violations

Violation list (5 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious140$900$500Nov 22, 1991--
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Serious11$900$500Dec 23, 1991--
01003A1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious14$1,575$1,000Sep 30, 1992--
01003B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious14$0$0Sep 30, 1992--
01004A1910.1025
Lead
OSHA citation code: 19101025 I04 III
Serious140$1,575$1,000May 20, 1992--

Showing the 5 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 18, 1990Follow-Up (F) · Partial scope, Health#102352911$01 viol.

Inspection #102352911

Dates

Opened
Jun 18, 1990
Closing Conference Date
Aug 23, 1990
Closed
Nov 27, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
44

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
21020 W. Good Hope Road, Lannon, WI 53046
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)1410P / 4A0mg/m³
Beryllium and Beryllium Compounds (as Be)1310P / 3A0mg/m³
Cadmium Fume (as Cd)1410P / 4A0 - 0.0017mg/m³
Chromium, Metal and Insoluble Salts1410P / 4A0 - 0.0998mg/m³
Cobalt, Metal, Dust and Fume (as Co)1410P / 4A0mg/m³
Copper Fume (as Cu)1410P / 4A0 - 0.1461mg/m³
Iron Oxide Fume1410P / 4A0 - 0.911mg/m³
Lead, Inorganic (as Pb)1410P / 4A0 - 0.0646mg/m³
Manganese Fume (as Mn)1410P / 4A0 - 0.0141mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)1410P / 4A0mg/m³
Nickel, Metal and Insoluble compounds (as Ni)1410P / 4A0 - 0.0608mg/m³
Vanadium fume (as V2O5)1410P / 4A0mg/m³
Zinc Oxide Fume1410P / 4A0 - 0.599mg/m³

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 E05
Other110$0$0Nov 13, 1990--
Inspections 1 to 10 of 13, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead22 citations · $8,025
1910.1053Respirable Crystalline Silica10 citations · $15,000
1910.1000Air Contaminants8 citations · $2,350

Chemical exposure sampling

Samples
475
Substances
19
Inspections
8

Sample results are listed in the record of each inspection that collected them.

Other inspected employers in Lannon, WI