Skip to content
SafetyRecord logoSafetyRecord
AL-ECTRIC, INCORPORATED
$3,100
penalties
6
viol.
1
insp.

AL-ECTRIC, INCORPORATED

4646 NORTH MARINE DRIVE, CHICAGO, IL 60640

Inspections
1
Jul 1991 to Jul 1991 · 0 safety, 1 health
Violations
6
across 1 inspection
Penalties on record
$3,100
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 9, 1991Unprogrammed Related (G) · Partial scope, Health#103074639$3,1006 viol.

Inspection #103074639

Dates

Opened
Jul 9, 1991
Closing Conference Date
Jul 10, 1991
Closed
Aug 20, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
7
Related Activity
1 complaint

Violations and Penalties

Total Violations
6
Violation Types
4 serious, 2 other-than-serious
Initial Penalties
$4,500
Penalties on Record
$3,100
Site Address
4646 North Marine Drive, Chicago, IL 60640
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious112$750$400Aug 28, 1991--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F07 IVC
Serious17$750$400Aug 1, 1991--
010031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIB
Serious17$750$400Jul 28, 1991--
010051926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIE
Serious17$750$400Aug 1, 1991--
010061926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIF
Other17$750$750Aug 8, 1991--
010071926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Other37$750$750Aug 1, 1991--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)4 citations · $2,300
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $800

Other inspected employers in CHICAGO, IL

All employers in CHICAGO →