Skip to content
SafetyRecord logoSafetyRecord
ALCAN GENERAL CONTRACTORS
$375
penalties
6
viol.
1
insp.

ALCAN GENERAL CONTRACTORS

417 1ST AVENUE, SEWARD, AK 99664

Inspections
1
Dec 1997 to Dec 1997 · 1 safety, 0 health
Violations
6
across 1 inspection
Penalties on record
$375
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 2, 1997Planned (H) · Complete scope, Safety#124093436$3756 viol.

Inspection #124093436

Dates

Opened
Dec 2, 1997
Closing Conference Date
Dec 3, 1997
Closed
Jan 23, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
7

Violations and Penalties

Total Violations
6
Violation Types
5 serious, 1 other-than-serious
Initial Penalties
$375
Penalties on Record
$375
Site Address
417 1st Avenue, Seward, AK 99664
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B01 III
Serious18$375$375Jan 14, 1998--
01001B1926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious11$0$0Jan 14, 1998--
01001C1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Serious11$0$0Jan 14, 1998--
01001D1926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Serious17$0$0Jan 14, 1998--
01001E1926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIF
Serious18$0$0Jan 14, 1998--
020011926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Other12$0$0Jan 19, 1998--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.403Electrical - General Requirements (Construction)2 citations · $375
1926.405Electrical - Wiring Methods (Construction)2 citations · $0
1926.404Electrical - Wiring Design and Protection (Construction)1 citation · $0

Other inspected employers in SEWARD, AK

All employers in SEWARD →