Skip to content
SafetyRecord logoSafetyRecord
AM TEX MACHINE PRODUCTS, INC
$10,563
penalties
11
viol.
4
insp.

AM TEX MACHINE PRODUCTS, INC

4517 BRITTMOORE RD, HOUSTON, TX 77041NAICS 332996 Fabricated Pipe and Pipe Fitting Manufacturing

Inspections
4
Jun 2001 to Sep 2022 · 4 safety, 0 health
Violations
11
across 4 inspections
Penalties on record
$10,563
latest amounts in DOL records
By classification
Serious 4Willful 0Repeat 0Other 6

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 12, 2022Follow-Up (F) · Partial scope, Safety#346213606$5,0002 viol.

Inspection #346213606

Dates

Opened
Sep 12, 2022
Closing Conference Date
Oct 28, 2022
Contested
Dec 5, 2022
Final Order
Apr 26, 2023
Closed
Jun 15, 2023

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
211

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$24,613
Penalties on Record
$5,000
Site Address
4517 Brittmoore Road, Houston, TX 77041
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C08
Other11$10,256$3,000Nov 25, 2022Dec 5, 2022Apr 26, 2023
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 J02 IV
Other14$14,357$2,000Nov 25, 2022Dec 5, 2022Apr 26, 2023
Jan 23, 2020Complaint (B) · Partial scope, Safety#344577333$00 viol.

Inspection #344577333

Dates

Opened
Jan 23, 2020
Closing Conference Date
Jan 23, 2020
Closed
Feb 28, 2020

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
200
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4517 Brittmoore Rd, Houston, TX 77041
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Nov 19, 2002Follow-Up (F) · Complete scope, Safety#304510761$00 viol.

Inspection #304510761

Dates

Opened
Nov 19, 2002
Closing Conference Date
Nov 19, 2002
Closed
Nov 21, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
64

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4517 Brittmoore Rd, Houston, TX 77041
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 21, 2001FatalityAccident (A) · Complete scope, Safety#304503626$5,5639 viol.

Inspection #304503626

Dates

Opened
Jun 21, 2001
Closing Conference Date
Nov 7, 2001
Contested
Dec 3, 2001
Final Order
Aug 8, 2002
Closed
Sep 11, 2002

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
64
Related Activity
1 accident

Violations and Penalties

Total Violations
9
Violation Types
4 serious, 4 other-than-serious, 1 unclassified
Initial Penalties
$11,125
Penalties on Record
$5,563
Site Address
4517 Brittmoore Rd, Houston, TX 77041
Industry
332996 Fabricated Pipe and Pipe Fitting Manufacturing

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

FatalityJun 20, 2001

Employee killed in fall from top of powered industrial truck

Injury: ConcussionBody part: HeadSource: Bodily MotionEvent: Caught In or Between

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L
Serious77$2,500$1,250Dec 4, 2001Dec 3, 2001Aug 8, 2002
010021910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious239$2,500$1,250Dec 4, 2001Dec 3, 2001Aug 8, 2002
010031910.303
Electrical - General Requirements
OSHA citation code: 19100303 C
Serious439$2,500$1,250Dec 4, 2001Dec 3, 2001Aug 8, 2002
010041910.303
Electrical - General Requirements
OSHA citation code: 19100303 F
Serious539$2,500$1,250Dec 4, 2001Dec 3, 2001Aug 8, 2002
010051910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IIIA
Unclassified439$500$250Dec 4, 2001Dec 3, 2001Aug 8, 2002
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other139$625$313Dec 4, 2001Dec 3, 2001Aug 8, 2002
020011910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Other139$0$0Dec 4, 2001Dec 3, 2001Aug 8, 2002
020021910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other339$0$0Dec 4, 2001Dec 3, 2001Aug 8, 2002
020031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Other939$0$0Dec 4, 2001Dec 3, 2001Aug 8, 2002
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment4 citations · $2,563
1910.303Electrical - General Requirements3 citations · $3,750
1910.22Walking-Working Surfaces - General Requirements1 citation · $0

Industry comparison

Violations per inspection
This employer2.8
Industry average3.3
Penalties per inspection
This employer$2,641
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,892 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: fabricated pipe and pipe fitting manufacturing reported 2.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 16.7%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in HOUSTON, TX

All employers in HOUSTON →