AMELIA COUNTY PUBLIC SCHOOL
RTE 38, Amelia Court House, VA 23002
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Sep 16, 2004#308030451Sep 16, 2004Planned (H) · Complete scope, Safety#308030451$017 viol.17 violations$0 in penalties
Inspection #308030451
Dates
- Opened
- Sep 16, 2004
- Closing Conference Date
- Sep 21, 2004
- Closed
- Dec 28, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 45
Violations and Penalties
- Total Violations
- 17
- Violation Types
- 7 serious, 10 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Vehicle Maintenance Facility, 8634 Otterburn Road, Amelia Court House, VA 23002
- Industry
- 811111 General Automotive Repair
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (16 of 17 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 2 | $0 | $0 | Dec 17, 2004 | - | - |
| 01001B | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C07 I | Serious | 1 | 2 | $0 | $0 | Dec 17, 2004 | - | - |
| 01002 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C05 I | Serious | 1 | 2 | $0 | $0 | Dec 3, 2004 | - | - |
| 01003A | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G01 | Serious | 1 | 2 | $0 | $0 | Dec 10, 2004 | - | - |
| 01003B | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G02 | Serious | 1 | 2 | $0 | $0 | Dec 10, 2004 | - | - |
| 01004 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 IVC | Serious | 2 | - | $0 | $0 | Dec 3, 2004 | - | - |
| 01005 | 1910.307 Hazardous (classified) locations OSHA citation code: 19100307 B | Serious | 1 | 2 | $0 | $0 | Dec 10, 2004 | - | - |
| 02001 | 1904.32 Annual Summary OSHA citation code: 19040032 A02 | Other | 5 | 6 | $0 | $0 | Dec 10, 2004 | - | - |
| 02002 | 1910.106 OSHA citation code: 19100106 D07 III | Other | 1 | 2 | $0 | $0 | Dec 3, 2004 | - | - |
| 02003 | 1910.110 Storage and Handling of Liquefied Petroleum Gases OSHA citation code: 19100110 B06 VI | Other | 1 | 2 | $0 | $0 | Dec 3, 2004 | - | - |
| 02004 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 2 | $0 | $0 | Nov 26, 2004 | - | - |
| 02005 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C04 | Other | 1 | 2 | $0 | $0 | Dec 3, 2004 | - | - |
| 02006 | 1910.303 OSHA citation code: 19100303 G01 II | Other | 1 | 2 | $0 | $0 | Dec 3, 2004 | - | - |
| 02007 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 2 | $0 | $0 | Dec 17, 2004 | - | - |
| 02008 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Other | 1 | 2 | $0 | $0 | Dec 3, 2004 | - | - |
| 02009 | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Other | 3 | 4 | $0 | $0 | Dec 10, 2004 | - | - |
Showing the 16 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Dec 14, 1998#301812145Dec 14, 1998Planned (H) · Complete scope, Safety#301812145$06 viol.6 violations$0 in penalties
Inspection #301812145
Dates
- Opened
- Dec 14, 1998
- Closing Conference Date
- Dec 21, 1998
- Closed
- Jan 25, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 4
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 5 serious, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Vehicle Maintenance Facility, 8634 Otterburn Road, Amelia Court House, VA 23002
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 OSHA citation code: 19100106 B02 VIIA | Serious | 1 | 4 | $0 | $0 | Feb 14, 1999 | - | - |
| 01002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E03 | Serious | 2 | 4 | $0 | $0 | Feb 14, 1999 | - | - |
| 01003 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G01 | Serious | 1 | 4 | $0 | $0 | Feb 14, 1999 | - | - |
| 01004 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G02 | Serious | 4 | 4 | $0 | $0 | Feb 14, 1999 | - | - |
| 01005 | 1910.177 Servicing Multi-Piece and Single Piece Rim Wheels OSHA citation code: 19100177 D05 | Serious | 1 | 4 | $0 | $0 | Feb 14, 1999 | - | - |
| 02001 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E03 | Other | 1 | 4 | $0 | $0 | Jan 4, 1999 | - | - |
Apr 19, 1983#12589925Apr 19, 1983Planned (H) · Complete scope, Safety#12589925$08 viol.8 violations$0 in penalties
Inspection #12589925
Dates
- Opened
- Apr 19, 1983
- Closing Conference Date
- Apr 20, 1983
- Closed
- Aug 7, 1985
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 3 serious, 5 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Rte 38, Amelia Court House, VA 23002
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 VC1 | Serious | 1 | - | $0 | $0 | Jun 1, 1983 | - | - |
| 01001B | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 VC8 | Serious | 1 | - | $0 | $0 | Jun 1, 1983 | - | - |
| 01001C | 1910.304 Wiring design and protection OSHA citation code: 19100304 F06 I | Serious | 6 | - | $0 | $0 | Jun 1, 1983 | - | - |
| 02001 | 1910.37 OSHA citation code: 19100037 F02 | Other | 1 | - | $0 | $0 | Aug 7, 1985 | - | - |
| 02002 | 1910.37 OSHA citation code: 19100037 Q01 | Other | 1 | - | $0 | $0 | Jun 1, 1983 | - | - |
| 02003 | 1910.141 Sanitation OSHA citation code: 19100141 D01 I | Other | 1 | - | $0 | $0 | Aug 7, 1985 | - | - |
| 02004 | 1910.141 Sanitation OSHA citation code: 19100141 D02 II | Other | 1 | - | $0 | $0 | Aug 7, 1985 | - | - |
| 02005 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C04 | Other | 1 | - | $0 | $0 | May 12, 1983 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 1983 to 2004. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: automotive repair and maintenance reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.8%; NAICS 8111 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source