Skip to content
SafetyRecord logoSafetyRecord
AMERICAN BOOK-STRATFORD PRESS
$2,205
penalties
36
viol.
5
insp.

AMERICAN BOOK-STRATFORD PRESS

95 MARNILL STREET, Saddle Brook, NJ 07662

Inspections
5
Dec 1979 to Aug 1982 · 5 safety, 0 health
Violations
36
across 5 inspections
Penalties on record
$2,205
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 28

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 12, 1982Planned (H) · Complete scope, Safety#11013398$10510 viol.

Inspection #11013398

Dates

Opened
Aug 12, 1982
Closing Conference Date
Aug 16, 1982
Closed
Sep 16, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
800

Violations and Penalties

Total Violations
10
Violation Types
1 serious, 9 other-than-serious
Initial Penalties
$210
Penalties on Record
$105
Site Address
95 Mayhill St, Saddle Brook, NJ 07662
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious4-$210$105Aug 30, 1982--
020011910.106
OSHA citation code: 19100106 E06 II
Other1-$0$0Aug 16, 1982--
020021910.169
Air Receivers
OSHA citation code: 19100169 B03 I
Other1-$0$0Aug 30, 1982--
020031910.178
Powered Industrial Trucks
OSHA citation code: 19100178 G02
Other1-$0$0Aug 30, 1982--
020041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Other2-$0$0Aug 16, 1982--
02005A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other1-$0$0Aug 16, 1982--
02005B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other1-$0$0Aug 16, 1982--
020061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 I02
Other1-$0$0Aug 13, 1982--
020071910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C01
Other1-$0$0Aug 16, 1982--
020081910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other2-$0$0Aug 12, 1982--
Sep 3, 1980Follow-Up (F) · Complete scope, Safety#11055290$00 viol.

Inspection #11055290

Dates

Opened
Sep 3, 1980
Closing Conference Date
Sep 3, 1980
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
900

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
95 Mayhill Street, Saddle Brook, NJ 07662
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 8, 1980Follow-Up (F) · Complete scope, Safety#11054962$00 viol.

Inspection #11054962

Dates

Opened
Apr 8, 1980
Closing Conference Date
Apr 8, 1980
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
900

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
95 Mayhill Street, Saddle Brook, NJ 07662
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 12, 1980Follow-Up (F) · Complete scope, Safety#11054897$00 viol.

Inspection #11054897

Dates

Opened
Mar 12, 1980
Closing Conference Date
Mar 12, 1980
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
900

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
95 Mayhill Street, Saddle Brook, NJ 07662
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Dec 21, 1979Planned (H) · Complete scope, Safety#11067279$2,10026 viol.

Inspection #11067279

Dates

Opened
Dec 21, 1979
Closing Conference Date
Jan 11, 1980
Contested
Feb 15, 1980
Closed
Sep 4, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
900

Violations and Penalties

Total Violations
26
Violation Types
7 serious, 19 other-than-serious
Initial Penalties
$2,100
Penalties on Record
$2,100
Site Address
95 Marnill Street, Saddle Brook, NJ 07662
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 26 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010015A0001
General Duty Clause, Section 5(a)(1)
Serious1-$300$300Feb 4, 1980Feb 15, 1980-
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious2-$240$240Mar 7, 1980Feb 15, 1980-
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious3-$300$300Feb 4, 1980Feb 15, 1980-
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious3-$0$0Feb 4, 1980--
010041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious7-$300$300Apr 7, 1980Feb 15, 1980-
010051910.309
OSHA citation code: 19100309 A 011017
Serious3-$420$420Feb 4, 1980Feb 15, 1980-
010061910.309
OSHA citation code: 19100309 B 040001
Serious1-$420$420Feb 4, 1980Feb 15, 1980-
020011910.22
OSHA citation code: 19100022 A01
Other1-$0$0Feb 4, 1980--
020021910.22
OSHA citation code: 19100022 B02
Other1-$0$0Mar 7, 1980--
020031910.23
OSHA citation code: 19100023 C01
Other2-$0$0Feb 4, 1980--

Showing the 10 violations listed first by citation identifier. This inspection has 26 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus7 citations · $600
1910.3097 citations · $840
1910.363 citations · $120

Other inspected employers in Saddle Brook, NJ

All employers in Saddle Brook →