ANTHONY RIVER INC
116 GRANGER ST, SYRACUSE, NY 13202
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Sep 20, 2011#315849216Sep 20, 2011Referral (C) · Complete scope, Safety#315849216$00 viol.0 violations$0 in penalties
Inspection #315849216
Dates
- Opened
- Sep 20, 2011
- Closing Conference Date
- Jan 4, 2012
- Closed
- Nov 19, 2015
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Jan 11, 2011#314349036Jan 11, 2011Follow-Up (F) · Partial scope, Health#314349036$5003 viol.3 violations$500 in penalties
Inspection #314349036
Dates
- Opened
- Jan 11, 2011
- Closing Conference Date
- Feb 22, 2011
- Contested
- Mar 29, 2011
- Final Order
- Sep 6, 2011
- Closed
- Sep 11, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 1 serious, 2 repeat
- Initial Penalties
- $5,400
- Penalties on Record
- $500
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C08 | Serious | 1 | 1 | $1,800 | $250 | Mar 9, 2011 | Mar 29, 2011 | Sep 6, 2011 |
| 02001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Repeat | 3 | 2 | $3,600 | $250 | May 6, 2011 | Mar 29, 2011 | Sep 6, 2011 |
| 02001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Repeat | 1 | 4 | $0 | $0 | May 6, 2011 | Mar 29, 2011 | Sep 6, 2011 |
May 20, 2010#314345273May 20, 2010Planned (H) · Complete scope, Health#314345273$3,39520 viol.20 violations$3,395 in penalties
Inspection #314345273
Dates
- Opened
- May 20, 2010
- Closing Conference Date
- Aug 3, 2010
- Closed
- Jan 27, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 16
Violations and Penalties
- Total Violations
- 20
- Violation Types
- 19 serious, 1 other-than-serious
- Initial Penalties
- $6,150
- Penalties on Record
- $3,395
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling3 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Chromic Acid and Chromates (as CrO3) | 2 | 0.000495 - 0.001643 | mg/m³ |
| Chromium (VI) - TWA | 2 | 0.000257 - 0.000855 | mg/m³ |
| Formaldehyde | 2 | 0 - 0.03202 | ppm |
Violations
Violation list (6 of 20 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IIB2 | Serious | 1 | 16 | $750 | $485 | Oct 25, 2010 | - | - |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Serious | 3 | 6 | $750 | $485 | Aug 26, 2010 | - | - |
| 01002B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 3 | 3 | $0 | $0 | Aug 26, 2010 | - | - |
| 01003A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Serious | 2 | 4 | $750 | $485 | Oct 25, 2010 | - | - |
| 01003B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 F03 | Serious | 1 | 2 | $0 | $0 | Aug 26, 2010 | - | - |
| 01004 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C01 | Other | 1 | 10 | $450 | $0 | Sep 25, 2010 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 20 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Feb 17, 2006#309379279Feb 17, 2006Planned (H) · Complete scope, Health#309379279$5,10019 viol.19 violations$5,100 in penalties
Inspection #309379279
Dates
- Opened
- Feb 17, 2006
- Closing Conference Date
- Mar 3, 2006
- Closed
- Dec 6, 2006
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 19
- Violation Types
- 19 serious
- Initial Penalties
- $5,100
- Penalties on Record
- $5,100
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling17 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| 2-Butanone | 7 | 0.21497 - 3.079113 | ppm |
| Antimony and Compounds (as Sb) | 5 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 5 | 0 | mg/m³ |
| Cadmium | 5 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 5 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 5 | 0 | mg/m³ |
| Copper Fume (as Cu) | 5 | 0 | mg/m³ |
| Hexone | 7 | 0 - 0.200101 | ppm |
| Iron Oxide Fume | 5 | 0 - 0.0759797 | mg/m³ |
| Lead, Inorganic (as Pb) | 5 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 5 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 5 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 5 | 0 | mg/m³ |
| Toluene | 7 | 0.430042 - 6.936181 | ppm |
| Vanadium fume (as V2O5) | 5 | 0 | mg/m³ |
| Xylene | 7 | 0 - 0.30729 | ppm |
| Zinc Oxide Fume | 5 | 0 - 0.0647367 | mg/m³ |
Violations
Violation list (6 of 19 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Serious | 1 | 1 | $600 | $600 | Jun 2, 2006 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B09 | Serious | 1 | 1 | $0 | $0 | Jun 2, 2006 | - | - |
| 01001C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 1 | 1 | $0 | $0 | May 18, 2006 | - | - |
| 01002A | 1910.124 General Requirements for Dipping and Coating Operations OSHA citation code: 19100124 F | Serious | 1 | 1 | $600 | $600 | Jun 2, 2006 | - | - |
| 01002B | 1910.124 General Requirements for Dipping and Coating Operations OSHA citation code: 19100124 H04 | Serious | 1 | 1 | $0 | $0 | Jul 15, 2006 | - | - |
| 01003A | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D01 I | Serious | 1 | 5 | $600 | $600 | Jun 19, 2006 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 19 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Feb 20, 1997#300624996Feb 20, 1997Planned (H) · Complete scope, Safety#300624996$1,1008 viol.8 violations$1,100 in penalties
Inspection #300624996
Dates
- Opened
- Feb 20, 1997
- Closing Conference Date
- Feb 28, 1997
- Closed
- Jul 29, 1997
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 14
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 7 serious, 1 other-than-serious
- Initial Penalties
- $1,800
- Penalties on Record
- $1,100
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVD | Serious | 3 | 1 | $375 | $225 | Mar 24, 1997 | - | - |
| 01002A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Serious | 3 | 3 | $375 | $225 | Jun 9, 1997 | - | - |
| 01002B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 2 | 3 | $0 | $0 | Mar 16, 1997 | - | - |
| 01003A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 E04 | Serious | 1 | 1 | $375 | $225 | Apr 8, 1997 | - | - |
| 01003B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 E09 | Serious | 1 | 1 | $0 | $0 | Mar 24, 1997 | - | - |
| 01004 | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 1 | $300 | $200 | Jun 9, 1997 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 8 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Apr 26, 1990#106814445Apr 26, 1990Planned (H) · Complete scope, Safety#106814445$51011 viol.11 violations$510 in penalties
Inspection #106814445
Dates
- Opened
- Apr 26, 1990
- Closing Conference Date
- Apr 26, 1990
- Closed
- Nov 20, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 11
- Violation Types
- 9 serious, 2 other-than-serious
- Initial Penalties
- $510
- Penalties on Record
- $510
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 11 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B03 | Serious | 4 | 4 | $210 | $210 | Jun 1, 1990 | - | - |
| 01001B | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 I | Serious | 4 | 4 | $0 | $0 | Jun 25, 1990 | - | - |
| 01001C | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B05 IV | Serious | 4 | 4 | $0 | $0 | Jul 11, 1990 | - | - |
| 01001D | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B09 | Serious | 2 | 4 | $0 | $0 | Jun 1, 1990 | - | - |
| 01001E | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 C06 | Serious | 3 | 2 | $0 | $0 | Jun 25, 1990 | - | - |
| 01001F | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 G02 | Serious | 4 | 4 | $0 | $0 | Jun 1, 1990 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 13, 1987#101529097May 13, 1987Planned (H) · Records Only scope, Safety#101529097$00 viol.0 violations$0 in penalties
Inspection #101529097
Dates
- Opened
- May 13, 1987
- Closing Conference Date
- May 13, 1987
- Closed
- May 13, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Oct 5, 1983#12047882Oct 5, 1983Planned (H) · Records Only scope, Safety#12047882$00 viol.0 violations$0 in penalties
Inspection #12047882
Dates
- Opened
- Oct 5, 1983
- Closing Conference Date
- Oct 5, 1983
- Closed
- Oct 5, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 19
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 116 Granger St, Syracuse, NY 13202
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
8 inspections, 1983 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source