Skip to content
SafetyRecord logoSafetyRecord
ARCHITECTURAL MASONRY INC.
$1,260
penalties
10
viol.
4
insp.

ARCHITECTURAL MASONRY INC.

7575 PRINCESS WAY, SCOTTSDALE, AZ 85255

Inspections
4
Feb 1987 to Feb 1988 · 4 safety, 0 health
Violations
10
across 4 inspections
Penalties on record
$1,260
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 2Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 17, 1988Planned (H) · Complete scope, Safety#103791414$00 viol.

Inspection #103791414

Dates

Opened
Feb 17, 1988
Closing Conference Date
Feb 17, 1988
Closed
Feb 19, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
7575 Princess Way, Scottsdale, AZ 85255
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Sep 21, 1987Planned (H) · Complete scope, Safety#103723458$02 viol.

Inspection #103723458

Dates

Opened
Sep 21, 1987
Closing Conference Date
Sep 21, 1987
Closed
Oct 21, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
100

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
7575 Princess Way, Princess Hotel, Scottsdale, AZ 85255
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Other19$0$0Oct 8, 1987--
010021926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Other11$0$0Oct 8, 1987--
May 14, 1987Follow-Up (F) · Complete scope, Safety#103706065$00 viol.

Inspection #103706065

Dates

Opened
May 14, 1987
Closing Conference Date
May 14, 1987
Closed
May 20, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
80

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
7575 Princess Way, Scottsdale, AZ 85255
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 13, 1987Planned (H) · Complete scope, Safety#2554558$1,2608 viol.

Inspection #2554558

Dates

Opened
Feb 13, 1987
Closing Conference Date
Feb 17, 1987
Closed
Nov 20, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
80

Violations and Penalties

Total Violations
8
Violation Types
3 serious, 2 repeat, 3 other-than-serious
Initial Penalties
$1,870
Penalties on Record
$1,260
Site Address
7575 Princess Way, Scottsdale, AZ 85255
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A13
Serious11$420$225Mar 13, 1987--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Serious13$640$225Mar 13, 1987--
010031926.700
Concrete and Masonry Construction - Scope, Application, and Definitions
OSHA citation code: 19260700 B02
Serious11$490$490Mar 13, 1987--
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Repeat12$160$160Mar 13, 1987--
020021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D03
Repeat16$160$160Mar 13, 1987--
030011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A14
Other13$0$0Mar 13, 1987--
030021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D04
Other13$0$0Mar 13, 1987--
030031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Other110$0$0Mar 13, 1987--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements7 citations · $770
1926.405Electrical - Wiring Methods (Construction)1 citation · $0
1926.416Electrical - Safety Requirements (Construction)1 citation · $0

Other inspected employers in SCOTTSDALE, AZ