Sep 5, 2023#346956287Sep 5, 2023Planned (H) · Partial scope, Safety#346956287$7,9703 viol.3 violations$7,970 in penalties
Inspection #346956287
Dates
- Opened
- Sep 5, 2023
- Closing Conference Date
- Sep 5, 2023
- Final Order
- Nov 1, 2023
- Closed
- Oct 31, 2023
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 32
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 2 serious, 1 other-than-serious
- Initial Penalties
- $13,282
- Penalties on Record
- $7,970
- Site Address
- 246 Sw 4th Ave., Homestead, FL 33030
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $6,641 | $3,985 | Oct 12, 2023 | - | Nov 1, 2023 |
| 01002 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 1 | $6,641 | $3,985 | - | Nov 1, 2023 | |
| 02001 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Other | 1 | 1 | $0 | $0 | - | Nov 1, 2023 |
Apr 13, 2016#341394922Apr 13, 2016Referral (C) · Partial scope, Health#341394922$1,2606 viol.6 violations$1,260 in penalties
Inspection #341394922
Dates
- Opened
- Apr 13, 2016
- Closing Conference Date
- Apr 13, 2016
- Final Order
- Aug 10, 2016
- Closed
- Aug 15, 2016
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 48
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 3 serious, 3 other-than-serious
- Initial Penalties
- $2,100
- Penalties on Record
- $1,260
- Site Address
- 246 Sw 4th Ave, Homestead, FL 33030
- Industry
- 332322 Sheet Metal Work Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 C | Serious | 1 | 8 | $2,100 | $1,260 | Aug 3, 2016 | - | Aug 10, 2016 |
| 01001B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 D01 | Serious | 1 | 18 | $0 | $0 | Aug 3, 2016 | - | Aug 10, 2016 |
| 01001C | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G05 I | Serious | 1 | 8 | $0 | $0 | Aug 3, 2016 | - | Aug 10, 2016 |
| 02001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 H01 | Other | 1 | 18 | $0 | $0 | - | Aug 10, 2016 | |
| 02002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C02 I | Other | 1 | 6 | $0 | $0 | Aug 3, 2016 | - | Aug 10, 2016 |
| 02003 | 1910.1200 Hazard Communication OSHA citation code: 19101200 H01 | Other | 1 | 18 | $0 | $0 | Aug 3, 2016 | - | Aug 10, 2016 |
Apr 13, 2016#341394674Apr 13, 2016Planned (H) · Partial scope, Safety#341394674$5,2905 viol.5 violations$5,290 in penalties
Inspection #341394674
Dates
- Opened
- Apr 13, 2016
- Closing Conference Date
- May 23, 2016
- Final Order
- Jul 12, 2016
- Closed
- Jan 18, 2017
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 48
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 3 serious, 2 other-than-serious
- Initial Penalties
- $7,558
- Penalties on Record
- $5,290
- Site Address
- 246 Sw 4th Ave, Homestead, FL 33030
- Industry
- 332322 Sheet Metal Work Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 3 | 1 | $3,273 | $2,291 | Jul 18, 2016 | - | Jul 12, 2016 |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Serious | 2 | 1 | $1,607 | $1,125 | - | Jul 12, 2016 | |
| 01003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 B02 | Serious | 1 | 1 | $2,142 | $1,499 | - | Jul 12, 2016 | |
| 02001 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 A01 II | Other | 1 | 1 | $0 | $0 | Jul 8, 2016 | - | Jul 12, 2016 |
| 02002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Other | 1 | 2 | $536 | $375 | - | Jul 12, 2016 |
Jul 19, 2011#315354902Jul 19, 2011Referral (C) · Partial scope, Health#315354902$00 viol.0 violations$0 in penalties
Inspection #315354902
Dates
- Opened
- Jul 19, 2011
- Closing Conference Date
- Oct 19, 2011
- Closed
- Oct 19, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
- Related Activity
- 1 referral
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 246 Sw 4th Ave., Homestead, FL 33030
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 1 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 1 | 0 | mg/m³ |
| Cadmium | 1 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 1 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 1 | 0 | mg/m³ |
| Copper Fume (as Cu) | 1 | 0.0380147 | mg/m³ |
| Iron Oxide Fume | 1 | 3.5960526 | mg/m³ |
| Lead, Inorganic (as Pb) | 1 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 1 | 0.0477574 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 1 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 1 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 1 | 0 | mg/m³ |
| Zinc Oxide Fume | 1 | 0 | mg/m³ |
Jul 12, 2011#315354704Jul 12, 2011Complaint (B) · Partial scope, Safety#315354704$2,1002 viol.2 violations$2,100 in penalties
Inspection #315354704
Dates
- Opened
- Jul 12, 2011
- Closing Conference Date
- Jul 12, 2011
- Closed
- Feb 1, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 35
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 serious
- Initial Penalties
- $2,100
- Penalties on Record
- $2,100
- Site Address
- 246 Sw 4th Ave., Homestead, FL 33030
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 P01 | Serious | 1 | 2 | $2,100 | $2,100 | Sep 28, 2011 | - | - |
| 01001B | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 Q01 | Serious | 1 | 2 | $0 | $0 | Sep 28, 2011 | - | - |
Jun 24, 2010#314263419Jun 24, 2010Complaint (B) · Partial scope, Health#314263419$3,5006 viol.6 violations$3,500 in penalties
Inspection #314263419
Dates
- Opened
- Jun 24, 2010
- Closing Conference Date
- Nov 19, 2010
- Closed
- Feb 1, 2012
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 35
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 4 serious, 2 other-than-serious
- Initial Penalties
- $3,500
- Penalties on Record
- $3,500
- Site Address
- 246 Sw 4th Avenue, Homestead, FL 33030
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling13 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 6 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 6 | 0 | mg/m³ |
| Cadmium | 6 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 6 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 6 | 0 | mg/m³ |
| Copper Fume (as Cu) | 6 | 0 - 0.010599 | mg/m³ |
| Iron Oxide Fume | 6 | 0.1006593 - 0.7986774 | mg/m³ |
| Lead, Inorganic (as Pb) | 6 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 6 | 0 - 0.0642209 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 6 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 6 | 0 | mg/m³ |
| Vanadium fume (as V2O5) | 6 | 0 | mg/m³ |
| Zinc Oxide Fume | 6 | 0 | mg/m³ |
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Serious | 1 | 25 | $875 | $875 | Feb 21, 2011 | - | - |
| 01002 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 1 | 1 | $875 | $875 | Dec 30, 2010 | - | - |
| 01003 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 1 | $875 | $875 | Dec 20, 2010 | - | - |
| 01004 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 1 | $875 | $875 | Dec 13, 2010 | - | - |
| 02001 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Other | 1 | 1 | $0 | $0 | Dec 20, 2010 | - | - |
| 02002 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 6 | $0 | $0 | Feb 21, 2011 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
6 inspections, 2010 to 2023. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Fabricated Metal Product Manufacturing, 45,863 employers with OSHA inspections. Arithmetic from DOL records.