Skip to content
SafetyRecord logoSafetyRecord
B & S SHEET METAL CO INC
$4,000
penalties
14
viol.
3
insp.

B & S SHEET METAL CO INC

51 59 4TH AVE, Hawthorne, NJ 07506

Inspections
3
Oct 1982 to Nov 1991 · 3 safety, 0 health
Violations
14
across 3 inspections
Penalties on record
$4,000
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 19, 1991Planned (H) · Complete scope, Safety#100707991$4,00014 viol.

Inspection #100707991

Dates

Opened
Nov 19, 1991
Closing Conference Date
Nov 19, 1991
Closed
Jun 2, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
20

Violations and Penalties

Total Violations
14
Violation Types
13 serious, 1 other-than-serious
Initial Penalties
$6,150
Penalties on Record
$4,000
Site Address
51-59 4th Avenue, Hawthorne, NJ 07506
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (14 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious13$450$400Jan 10, 1992--
010021910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C01
Serious110$750$400Feb 10, 1992--
010031910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C05 I
Serious110$750$400Feb 10, 1992--
010041910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 C07 I
Serious110$750$400Feb 10, 1992--
010051910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 G01
Serious117$450$400Feb 10, 1992--
01006A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$600$400Feb 10, 1992--
01006B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$0$0Feb 10, 1992--
010071910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Serious24$600$400Feb 10, 1992--
010081910.303
OSHA citation code: 19100303 G02 I
Serious14$600$400Jan 27, 1992--
01009A1910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Serious110$600$400Feb 10, 1992--
01009B1910.1200
Hazard Communication
OSHA citation code: 19101200 G08
Serious110$0$0Feb 10, 1992--
01010A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Serious26$600$400Feb 10, 1992--
01010B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Serious26$0$0Feb 10, 1992--
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 C01
Other14$0$0Jan 27, 1992--
Jun 17, 1986Planned (H) · Records Only scope, Safety#100726298$00 viol.

Inspection #100726298

Dates

Opened
Jun 17, 1986
Closing Conference Date
Jun 17, 1986
Closed
Jun 17, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
15

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
51-57 Fourth Avenue, Hawthorne, NJ 07506
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Oct 29, 1982Planned (H) · Records Only scope, Safety#11057288$00 viol.

Inspection #11057288

Dates

Opened
Oct 29, 1982
Closing Conference Date
Oct 29, 1982
Closed
Oct 29, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
51 59 4th Ave, Hawthorne, NJ 07506
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication4 citations · $800
1910.147The control of hazardous energy (lockout/tagout)3 citations · $1,200
1910.219Mechanical Power-Transmission Apparatus2 citations · $400

Other inspected employers in Hawthorne, NJ

All employers in Hawthorne →