Skip to content
SafetyRecord logoSafetyRecord
BECK DEVELOPERS, LLC
$2,830
penalties
14
viol.
3
insp.

BECK DEVELOPERS, LLC

45034 UNDERWOOD LANE, #201, STERLING, VA 20166NAICS 332313 Plate Work Manufacturing

Inspections
3
Oct 2013 to May 2024 · 3 safety, 0 health
Violations
14
across 3 inspections
Penalties on record
$2,830
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 30, 2024Follow-Up (F) · Partial scope, Safety#347513889$00 viol.

Inspection #347513889

Dates

Opened
May 30, 2024
Closing Conference Date
May 30, 2024
Closed
Nov 25, 2024

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
45034 Underwood Lane, #201, Sterling, VA 20166
Industry
332313 Plate Work Manufacturing

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 4, 2023Final Order RecordedPlanned (H) · Complete scope, Safety#347009805$2,20011 viol.

Inspection #347009805

Dates

Opened
Oct 4, 2023
Closing Conference Date
Oct 4, 2023
Final Order
Feb 23, 2024
Closed
No close date in inspection feed

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
11
Violation Types
9 serious, 2 other-than-serious
Initial Penalties
$2,200
Penalties on Record
$2,200
Site Address
45034 Underwood Lane, #201, Sterling, VA 20166
Industry
332313 Plate Work Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

OSHA's inspection feed still shows no close date for this record. However, the citation records tied to this inspection show final orders recorded through Feb 23, 2024.

Violations

Violation list (11 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.178
Powered Industrial Trucks
OSHA citation code: 19100178 L01 I
Serious11$600$600Jan 18, 2024-Jan 23, 2024
01002A1910.303
Electrical - General Requirements
OSHA citation code: 19100303 G02 I
Serious22$600$600Jan 5, 2024-Jan 23, 2024
01002B1910.303
Electrical - General Requirements
OSHA citation code: 19100303 B07 IV
Serious12$0$0Jan 5, 2024-Jan 23, 2024
01002C1910.303
Electrical - General Requirements
OSHA citation code: 19100303 F02
Serious22$0$0Jan 5, 2024-Jan 23, 2024
01002D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 I
Serious22$0$0Jan 5, 2024-Jan 23, 2024
01002E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Serious22$0$0Jan 5, 2024-Jan 23, 2024
01002F1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IV A
Serious22$0$0Jan 5, 2024-Jan 23, 2024
01002G1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious22$0$0Jan 5, 2024-Jan 23, 2024
01002H1910.334
Electrical - Use of Equipment
OSHA citation code: 19100334 A02 I
Serious22$0$0Jan 5, 2024-Jan 23, 2024
020011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02 I
Other22$0$0Jan 5, 2024-Jan 23, 2024
0300116VAC25-60-307.E.1Other109$1,000$1,000Mar 4, 2024-Feb 23, 2024

Failure to Abate Penalties10 citations, $60,000 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 10 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01002A#1751388Nov 19, 2024$30,000Dec 18, 2024-
01002B#1751388Nov 19, 2024-Dec 18, 2024-
01002C#1751388Nov 19, 2024-Dec 18, 2024-
01002D#1751388Nov 19, 2024-Dec 18, 2024-
01002E#1751388Nov 19, 2024-Dec 18, 2024-
01002F#1751388Nov 19, 2024-Dec 18, 2024-
01002G#1751388Nov 19, 2024-Dec 18, 2024-
01002H#1751388Nov 19, 2024-Dec 18, 2024-
02001#1751388Nov 19, 2024$30,000Dec 18, 2024-
03001#1751388Nov 19, 2024-Dec 18, 2024-
Oct 22, 2013Planned (H) · Complete scope, Safety#317349652$6303 viol.

Inspection #317349652

Dates

Opened
Oct 22, 2013
Closing Conference Date
Oct 22, 2013
Closed
Dec 11, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
9

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$630
Penalties on Record
$630
Site Address
45034 Underwood Lane, Suite 201, Sterling, VA 20166
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.101
Compressed Gases (General Requirements)
OSHA citation code: 19100101 B
Serious89$315$315Dec 5, 2013--
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious29$315$315Dec 5, 2013--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 B06
Other19$0$0Dec 5, 2013--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment6 citations · $315
1910.303Electrical - General Requirements3 citations · $600
1910.101Compressed Gases (General Requirements)1 citation · $315

Industry comparison

Violations per inspection
This employer4.7
Industry average3.3
Penalties per inspection
This employer$943
Industry average$2,287

Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in STERLING, VA

All employers in STERLING →