Skip to content
SafetyRecord logoSafetyRecord
BLACK MICRO CORPORATION
$120
penalties
12
viol.
8
insp.

BLACK MICRO CORPORATION

BARRACKS/GALLEY COMPLEX, SAN VICENTE, MP 96950

Inspections
8
Nov 1986 to Feb 1989 · 8 safety, 0 health
Violations
12
across 8 inspections
Penalties on record
$120
latest amounts in DOL records
By classification
Serious 1Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 25, 1989Planned (H) · Complete scope, Safety#2109734$1203 viol.

Inspection #2109734

Dates

Opened
Feb 25, 1989
Closing Conference Date
Feb 25, 1989
Closed
Apr 25, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
124

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$120
Penalties on Record
$120
Site Address
Office/Maintenance Shop Complex, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.441
Batteries and Battery Charging
OSHA citation code: 19260441 A06
Serious11$120$120Mar 22, 1989--
020011904.5
OSHA citation code: 19040005 C
Other110$0$0Mar 13, 1989--
020021926.302
Power-Operated Hand Tools
OSHA citation code: 19260302 B04
Other11$0$0Mar 22, 1989--
Feb 25, 1989Planned (H) · Complete scope, Safety#2109726$00 viol.

Inspection #2109726

Dates

Opened
Feb 25, 1989
Closing Conference Date
Feb 25, 1989
Closed
Mar 8, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
124

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Barracks/Galley Complex, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Feb 24, 1989Planned (H) · Complete scope, Safety#2109692$00 viol.

Inspection #2109692

Dates

Opened
Feb 24, 1989
Closing Conference Date
Feb 24, 1989
Closed
Mar 8, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
124

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Airport Restaurant A/C Project, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 27, 1988Planned (H) · Complete scope, Safety#2109189$03 viol.

Inspection #2109189

Dates

Opened
Apr 27, 1988
Closing Conference Date
Apr 27, 1988
Closed
May 26, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
63

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Office/Maintenance Shop Complex, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.300
General requirements
OSHA citation code: 19260300 B02
Other11$0$0May 8, 1988--
010021926.351
Arc Welding and Cutting
OSHA citation code: 19260351 B04
Other11$0$0May 8, 1988--
010031926.602
Material Handling Equipment
OSHA citation code: 19260602 C01 VI
Other12$0$0May 8, 1988--
Apr 27, 1988Planned (H) · Complete scope, Safety#2108546$01 viol.

Inspection #2108546

Dates

Opened
Apr 27, 1988
Closing Conference Date
Apr 27, 1988
Closed
May 26, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
63

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Labor Barracks/Galley Complex, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.150
Fire Protection (Construction)
OSHA citation code: 19260150 C01 I
Other110$0$0May 8, 1988--
Apr 27, 1988Planned (H) · Complete scope, Safety#2108538$02 viol.

Inspection #2108538

Dates

Opened
Apr 27, 1988
Closing Conference Date
Apr 27, 1988
Closed
Jun 6, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
63

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Saipan Airport Project, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.350
Gas Welding and Cutting
OSHA citation code: 19260350 A09
Other12$0$0May 12, 1988--
010021926.601
Motor Vehicles
OSHA citation code: 19260601 B04
Other11$0$0May 18, 1988--
May 7, 1987Planned (H) · Complete scope, Safety#2102150$03 viol.

Inspection #2102150

Dates

Opened
May 7, 1987
Closing Conference Date
May 7, 1987
Closed
Jun 17, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
50

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Saipan Airport Project, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Other11$0$0May 17, 1987--
010021926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Other11$0$0May 17, 1987--
010031926.450
Scaffolding - Scope, Application, and Definitions
OSHA citation code: 19260450 B12
Other22$0$0May 17, 1987--
Nov 13, 1986Planned (H) · Complete scope, Safety#2244473$00 viol.

Inspection #2244473

Dates

Opened
Nov 13, 1986
Closing Conference Date
Nov 13, 1986
Closed
Nov 19, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Office And Maintenance Shop Complex-Airport Road, San Vicente, MP 96950
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 8 of 8, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1904.51 citation · $0
1926.150Fire Protection (Construction)1 citation · $0
1926.300General requirements1 citation · $0

Other inspected employers in SAN VICENTE, MP