Skip to content
SafetyRecord logoSafetyRecord
BLACK RIVER PLASTICS PLANT #II
$4,197
penalties
26
viol.
3
insp.

BLACK RIVER PLASTICS PLANT #II

2345 PETIT, PORT HURON, MI 48060NAICS 326199 All Other Plastics Product Manufacturing

Inspections
3
May 2007 to Feb 2008 · 3 safety, 0 health
Violations
26
across 3 inspections
Penalties on record
$4,197
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 2Other 16

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 5, 2008Planned (H) · Complete scope, Safety#308826171$2,18418 viol.

Inspection #308826171

Dates

Opened
Feb 5, 2008
Closing Conference Date
Apr 1, 2008
Closed
May 28, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
200

Violations and Penalties

Total Violations
18
Violation Types
4 serious, 1 repeat, 13 other-than-serious
Initial Penalties
$4,365
Penalties on Record
$2,184
Site Address
2345 Petit, Port Huron, MI 48060
Industry
326199 All Other Plastics Product Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (16 of 18 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010014081003408Serious12$975$488May 2, 2008--
010024081021302Serious22$1,300$650May 20, 2008--
010034081063202Serious110$975$488May 2, 2008--
010044081.6251Serious12$975$488May 2, 2008--
020014081001501Other610$0$0May 20, 2008--
020024081003402Other22$0$0May 2, 2008--
020034081063201Other22$0$0May 20, 2008--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Other12$0$0May 20, 2008--
020051910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01
Other12$0$0May 20, 2008--
020061910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 B03 I
Other110$0$0May 2, 2008--
020071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01 II
Other13$0$0May 2, 2008--
020081910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 F04
Other12$0$0May 2, 2008--
020091910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Other2-$0$0May 20, 2008--
020104081624701Other12$0$0May 20, 2008--
020111910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Other15$0$0May 20, 2008--
020121910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C07 IB
Other110$0$0May 20, 2008--

Showing the 16 violations listed first by citation identifier. This inspection has 18 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Feb 5, 2008Complaint (B) · Partial scope, Safety#308826122$1,4635 viol.

Inspection #308826122

Dates

Opened
Feb 5, 2008
Closing Conference Date
Mar 25, 2008
Closed
Jul 8, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
200
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
1 serious, 1 repeat, 3 other-than-serious
Initial Penalties
$2,925
Penalties on Record
$1,463
Site Address
2345 Petit, Port Huron, MI 48060
Industry
326199 All Other Plastics Product Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010014081621101Serious12$975$488Jun 7, 2008--
020014081001503Repeat17$1,950$975Jun 7, 2008--
030014081216101
OSHA citation code: 4081216101 A
Other11$0$0Jun 7, 2008--
030024081213101Other12$0$0May 20, 2008--
030034081261602Other12$0$0May 20, 2008--
May 1, 2007Programmed Related (I) · Partial scope, Safety#308801430$5503 viol.

Inspection #308801430

Dates

Opened
May 1, 2007
Closing Conference Date
Jun 20, 2007
Closed
Aug 9, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
125

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,100
Penalties on Record
$550
Site Address
2345 Petit, Port Huron, MI 48060
Industry
326199 All Other Plastics Product Manufacturing

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A4081.6223Serious12$1,100$550Aug 6, 2007--
01001B4081.11
OSHA citation code: 40810011 A
Serious12$0$0Jul 19, 2007--
01001C4081001503Serious12$0$0Jul 19, 2007--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

40810015033 citations · $1,045
1910.305Electrical - Wiring Methods, Components, and Equipment3 citations · $0
1910.303Electrical - General Requirements2 citations · $0

Industry comparison

Violations per inspection
This employer8.7
Industry average2.8
Penalties per inspection
This employer$1,399
Industry average$3,072

Plastics and Rubber Products Manufacturing, 13,333 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in PORT HURON, MI

All employers in PORT HURON →