Skip to content
SafetyRecord logoSafetyRecord
BRANAM ELECTRIC CO INC
$420
penalties
6
viol.
4
insp.

BRANAM ELECTRIC CO INC

2800 MARTIN LUTHER KING AVENUE, Knoxville, TN 37914

Inspections
4
Jun 1991 to Aug 2004 · 4 safety, 0 health
Violations
6
across 4 inspections
Penalties on record
$420
latest amounts in DOL records
By classification
Serious 3Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 3, 2004Planned (H) · Complete scope, Safety#307681247$01 viol.

Inspection #307681247

Dates

Opened
Aug 3, 2004
Closing Conference Date
Aug 3, 2004
Closed
Oct 20, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
600 Chilhowee Drive, Knoxville, TN 37924
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01
Other11$0$0Sep 12, 2004--
Aug 11, 1997Planned (H) · Complete scope, Safety#127324747$3002 viol.

Inspection #127324747

Dates

Opened
Aug 11, 1997
Closing Conference Date
Aug 11, 1997
Closed
Nov 7, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$300
Penalties on Record
$300
Site Address
2800 Martin Luther King Avenue, Knoxville, TN 37914
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious12$150$150Oct 24, 1997--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B02
Serious32$150$150Oct 24, 1997--
Jan 23, 1992Planned (H) · Complete scope, Safety#114472301$01 viol.

Inspection #114472301

Dates

Opened
Jan 23, 1992
Closing Conference Date
Jan 23, 1992
Closed
Feb 25, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
3326 Sutherland Avenue, Knoxville, TN 37919
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E08
Other11$0$0Feb 13, 1992--
Jun 21, 1991Planned (H) · Complete scope, Safety#111079232$1202 viol.

Inspection #111079232

Dates

Opened
Jun 21, 1991
Closing Conference Date
Jun 21, 1991
Closed
Jul 18, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
2
Violation Types
1 serious, 1 other-than-serious
Initial Penalties
$120
Penalties on Record
$120
Site Address
3326 Sutherland Avenue, Knoxville, TN 37919
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 I
Serious12$120$120Jul 1, 1991--
020011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B01
Other12$0$0Jul 1, 1991--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $270
1926.405Electrical - Wiring Methods (Construction)2 citations · $150
1926.451Scaffolding - General Requirements1 citation · $0

Industry comparison

BLS 2024 survey: electrical contractors and other wiring installation contractors reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.7%; NAICS 23821 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Knoxville, TN

All employers in Knoxville →