CABARET CABINETRY INC.
HWY 77 E & RANCH RD, HAYWARD, WI 54843
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Oct 24, 2007#307043786Oct 24, 2007Planned (H) · Partial scope, Safety#307043786$2,43030 viol.30 violations$2,430 in penalties
Inspection #307043786
Dates
- Opened
- Oct 24, 2007
- Closing Conference Date
- Oct 24, 2007
- Closed
- Nov 8, 2008
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 24
Violations and Penalties
- Total Violations
- 30
- Violation Types
- 29 serious, 1 other-than-serious
- Initial Penalties
- $4,050
- Penalties on Record
- $2,430
- Site Address
- 10409 Vermont Ave., Hayward, WI 54843
- Industry
- 337110 Wood Kitchen Cabinet and Countertop Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (25 of 30 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 Ladders OSHA citation code: 19100023 C01 | Serious | 2 | 3 | $375 | $225 | Nov 1, 2008 | - | - |
| 01002A | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C01 | Serious | 2 | 24 | $375 | $225 | Mar 21, 2008 | - | - |
| 01002B | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C02 | Serious | 2 | 24 | $0 | $0 | Mar 21, 2008 | - | - |
| 01002C | 1910.146 Permit-Required Confined Spaces OSHA citation code: 19100146 C03 | Serious | 1 | 24 | $0 | $0 | Mar 21, 2008 | - | - |
| 01003A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 I | Serious | 1 | 24 | $375 | $225 | Apr 30, 2008 | - | - |
| 01003B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 IIA | Serious | 1 | 24 | $0 | $0 | Apr 30, 2008 | - | - |
| 01003C | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 IIB | Serious | 1 | 24 | $0 | $0 | Apr 30, 2008 | - | - |
| 01003D | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 IIC | Serious | 1 | 24 | $0 | $0 | Apr 30, 2008 | - | - |
| 01003E | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C04 IID | Serious | 1 | 24 | $0 | $0 | Apr 30, 2008 | - | - |
| 01003F | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 24 | $0 | $0 | Apr 30, 2008 | - | - |
| 01003G | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 D04 I | Serious | 1 | 2 | $0 | $0 | Apr 30, 2008 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A02 | Serious | 1 | 3 | $375 | $225 | Mar 31, 2008 | - | - |
| 01005 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Serious | 2 | 2 | $375 | $225 | Feb 14, 2008 | - | - |
| 01006A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C02 | Serious | 1 | 1 | $300 | $180 | Feb 7, 2008 | - | - |
| 01006B | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C03 | Serious | 1 | 1 | $0 | $0 | Feb 7, 2008 | - | - |
| 01007 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 P04 | Serious | 2 | 1 | $375 | $225 | Feb 29, 2008 | - | - |
| 01008A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 1 | $375 | $225 | Feb 22, 2008 | - | - |
| 01008B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E03 I | Serious | 1 | 1 | $0 | $0 | Feb 22, 2008 | - | - |
| 01009 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F01 | Serious | 1 | 3 | $375 | $225 | Feb 14, 2008 | - | - |
| 01010 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B01 II | Serious | 1 | 1 | $375 | $225 | Feb 14, 2008 | - | - |
| 01011A | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 IIB | Serious | 1 | 2 | $375 | $225 | May 30, 2008 | - | - |
| 01011B | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 VIIA | Serious | 1 | 2 | $0 | $0 | May 30, 2008 | - | - |
| 01011C | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 VIID | Serious | 1 | 2 | $0 | $0 | May 30, 2008 | - | - |
| 01011D | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02VIII | Serious | 1 | 2 | $0 | $0 | May 30, 2008 | - | - |
| 01011E | 1910.1030 Bloodborne Pathogens OSHA citation code: 19101030 G02 VIIK | Serious | 1 | 2 | $0 | $0 | May 30, 2008 | - | - |
Showing the 25 violations listed first by citation identifier. This inspection has 30 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Aug 30, 1994#106047574Aug 30, 1994Planned (H) · Complete scope, Safety#106047574$1,27510 viol.10 violations$1,275 in penalties
Inspection #106047574
Dates
- Opened
- Aug 30, 1994
- Closing Conference Date
- Aug 30, 1994
- Closed
- Nov 22, 1994
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 18
Violations and Penalties
- Total Violations
- 10
- Violation Types
- 9 serious, 1 other-than-serious
- Initial Penalties
- $2,550
- Penalties on Record
- $1,275
- Site Address
- Hwy 77 E & Ranch Rd, Hayward, WI 54843
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (10 of 10 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 1 | 18 | $600 | $300 | Oct 28, 1994 | - | - |
| 01002A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C01 | Serious | 1 | 4 | $600 | $300 | Oct 12, 1994 | - | - |
| 01002B | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C02 | Serious | 1 | 4 | $0 | $0 | Oct 12, 1994 | - | - |
| 01002C | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 C03 | Serious | 1 | 4 | $0 | $0 | Oct 12, 1994 | - | - |
| 01003A | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H01 | Serious | 1 | 4 | $600 | $300 | Oct 28, 1994 | - | - |
| 01003B | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 1 | 4 | $0 | $0 | Oct 28, 1994 | - | - |
| 01004A | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 18 | $750 | $375 | Oct 28, 1994 | - | - |
| 01004B | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Serious | 1 | 18 | $0 | $0 | Oct 28, 1994 | - | - |
| 01004C | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Serious | 1 | 18 | $0 | $0 | Oct 28, 1994 | - | - |
| 02001 | 1904.2 Partial Exemption for Establishments in Certain Industries OSHA citation code: 19040002 A | Other | 1 | 18 | $0 | $0 | Sep 23, 1994 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 1994 to 2007. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Industry comparison
BLS 2024 survey: wood kitchen cabinet and countertop manufacturing reported 3.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.2%; NAICS 33711 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source