CABLE FORM INC
ZION CROSSROADS, Troy, VA 22974
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Oct 17, 2005#309463305Oct 17, 2005Planned (H) · Complete scope, Health#309463305$3,15027 viol.27 violations$3,150 in penalties
Inspection #309463305
Dates
- Opened
- Oct 17, 2005
- Closing Conference Date
- Oct 18, 2005
- Closed
- Dec 13, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 28
Violations and Penalties
- Total Violations
- 27
- Violation Types
- 22 serious, 5 other-than-serious
- Initial Penalties
- $5,250
- Penalties on Record
- $3,150
- Site Address
- 8845 Three Notch Road, Troy, VA 22974
- Industry
- 335314 Relay and Industrial Control Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (25 of 27 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.106 Flammable Liquids OSHA citation code: 19100106 D06 III | Serious | 1 | 1 | $525 | $315 | Nov 22, 2005 | - | - |
| 01001B | 1910.106 Flammable Liquids OSHA citation code: 19100106 D07 I | Serious | 1 | 1 | $0 | $0 | Nov 22, 2005 | - | - |
| 01001C | 1910.106 Flammable Liquids OSHA citation code: 19100106 E06 II | Serious | 1 | 1 | $0 | $0 | Nov 22, 2005 | - | - |
| 01002A | 1910.110 Storage and Handling of Liquefied Petroleum Gases OSHA citation code: 19100110 D10 | Serious | 2 | 1 | $525 | $315 | Jan 20, 2006 | - | - |
| 01002B | 1910.110 Storage and Handling of Liquefied Petroleum Gases OSHA citation code: 19100110 F07 | Serious | 2 | 1 | $0 | $0 | Apr 18, 2006 | - | - |
| 01003A | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Serious | 5 | 1 | $525 | $315 | Nov 22, 2005 | - | - |
| 01003B | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C05 I | Serious | 5 | 2 | $0 | $0 | Nov 22, 2005 | - | - |
| 01003C | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 I | Serious | 1 | 10 | $0 | $0 | Nov 22, 2005 | - | - |
| 01004A | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 B | Serious | 1 | 2 | $525 | $315 | Nov 22, 2005 | - | - |
| 01004B | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 45 | 45 | $0 | $0 | Jan 20, 2006 | - | - |
| 01005A | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 C01 | Serious | 4 | 18 | $525 | $315 | Nov 22, 2005 | - | - |
| 01005B | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E03 | Serious | 4 | 18 | $0 | $0 | Nov 22, 2005 | - | - |
| 01005C | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G02 | Serious | 1 | 28 | $0 | $0 | Nov 22, 2005 | - | - |
| 01005D | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G04 | Serious | 1 | 28 | $0 | $0 | Nov 22, 2005 | - | - |
| 01006A | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L06 | Serious | 1 | 2 | $525 | $315 | Nov 22, 2005 | - | - |
| 01006B | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 L01 I | Serious | 1 | 2 | $0 | $0 | Nov 22, 2005 | - | - |
| 01007A | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 1 | $525 | $315 | Nov 22, 2005 | - | - |
| 01007B | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 1 | $0 | $0 | Nov 22, 2005 | - | - |
| 01008 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G01 I | Serious | 1 | 15 | $525 | $315 | Nov 22, 2005 | - | - |
| 01009A | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 II | Serious | 5 | 18 | $525 | $315 | Nov 22, 2005 | - | - |
| 01009B | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G01 III | Serious | 5 | 18 | $0 | $0 | Nov 22, 2005 | - | - |
| 01010 | 1910.1025 Lead OSHA citation code: 19101025 D02 | Serious | 1 | 101 | $525 | $315 | Nov 22, 2005 | - | - |
| 02001 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 Q02 | Other | 8 | 18 | $0 | $0 | Nov 22, 2005 | - | - |
| 02002 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 D02 | Other | 18 | 18 | $0 | $0 | Nov 22, 2005 | - | - |
| 02003 | 1910.134 Respiratory Protection OSHA citation code: 19100134 B06 | Other | 1 | 15 | $0 | $0 | Nov 22, 2005 | - | - |
Showing the 25 violations listed first by citation identifier. This inspection has 27 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
May 4, 1983#12618823May 4, 1983Planned (H) · Complete scope, Health#12618823$00 viol.0 violations$0 in penalties
Inspection #12618823
Dates
- Opened
- May 4, 1983
- Closing Conference Date
- Jun 3, 1983
- Closed
- Jun 3, 1983
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Zion Crossroads, Troy, VA 22974
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
2 inspections, 1983 to 2005. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: relay and industrial control manufacturing reported 0.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 13.5%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source