CABRAS MARINE CORPORATION
$15,864
penalties
7
viol.
2
insp.

CABRAS MARINE CORPORATION

NAVAL BASE GUAM SHIPYARD, Santa Rita, GU 96915NAICS 336611 Ship Building and Repairing

Inspections
2
Apr 2016 to Apr 2016 · 1 safety, 1 health
Violations
7
across 2 inspections
Penalties on record
$15,864
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 21, 2016Referral (C) · Complete scope, Health#341410736$4,2001 viol.

Inspection #341410736

Dates

Opened
Apr 21, 2016
Closing Conference Date
Apr 22, 2016
Final Order
Jul 15, 2016
Closed
Aug 17, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
100
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$4,200
Penalties on Record
$4,200
Site Address
Naval Base Guam Shipyard, Santa Rita, GU 96915
Industry
336611 Ship Building and Repairing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.134
Respiratory Protection
OSHA citation code: 19100134 H04
Serious11$4,200$4,200-Jul 15, 2016
Apr 21, 2016Referral (C) · Complete scope, Safety#341410728$11,6646 viol.

Inspection #341410728

Dates

Opened
Apr 21, 2016
Closing Conference Date
Apr 22, 2016
Final Order
Jul 15, 2016
Closed
Aug 17, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
140
Related Activity
1 referral

Violations and Penalties

Total Violations
6
Violation Types
4 serious, 2 other-than-serious
Initial Penalties
$11,664
Penalties on Record
$11,664
Site Address
Naval Base Guam Shipyard, Santa Rita, GU 96915
Industry
336611 Ship Building and Repairing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$2,430$2,430Jul 8, 2016-Jul 15, 2016
010021910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 C01
Serious11$3,240$3,240Jul 8, 2016-Jul 15, 2016
010031910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious11$3,240$3,240Jul 8, 2016-Jul 15, 2016
010041910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious11$2,754$2,754-Jul 15, 2016
020011910.157
Portable Fire Extinguishers
OSHA citation code: 19100157 E02
Other12$0$0-Jul 15, 2016
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 B
Other11$0$0Jul 8, 2016-Jul 15, 2016
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.213Woodworking Machinery Requirements3 citations · $9,234
1910.212General Requirements for All Machines (Machine Guarding)2 citations · $2,430
1910.134Respiratory Protection1 citation · $4,200

Industry comparison

Violations per inspection
This employer3.5
Industry average3.0
Penalties per inspection
This employer$7,932
Industry average$2,719

Transportation Equipment Manufacturing, 15,830 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: ship building and repairing reported 4.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 4.1%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Santa Rita, GU