Skip to content
SafetyRecord logoSafetyRecord
CHEMICAL FABRICS CORP
$1,270
penalties
16
viol.
3
insp.

CHEMICAL FABRICS CORP

WATER ST, North Bennington, VT 05257

Inspections
3
Dec 1983 to Mar 1989 · 2 safety, 1 health
Violations
16
across 3 inspections
Penalties on record
$1,270
latest amounts in DOL records
By classification
Serious 7Willful 0Repeat 1Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 23, 1989Planned (H) · Complete scope, Safety#105654909$5007 viol.

Inspection #105654909

Dates

Opened
Mar 23, 1989
Closing Conference Date
Mar 23, 1989
Closed
May 15, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
80

Violations and Penalties

Total Violations
7
Violation Types
5 serious, 2 other-than-serious
Initial Penalties
$500
Penalties on Record
$500
Site Address
Water Street, North Bennington, VT 05257
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious780$500$500Apr 24, 1989--
01001B1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 A04 V
Serious16$0$0Apr 24, 1989--
01001C1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious26$0$0Apr 24, 1989--
01001D1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B01
Serious112$0$0Apr 24, 1989--
01001E1910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G02 III
Serious16$0$0Apr 24, 1989--
020011910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other25$0$0Apr 15, 1989--
020021910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 A02 IVC
Other112$0$0Apr 15, 1989--
Aug 7, 1986Planned (H) · Complete scope, Health#3290848$03 viol.

Inspection #3290848

Dates

Opened
Aug 7, 1986
Closing Conference Date
Oct 21, 1986
Closed
Dec 24, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
67

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Water Street, North Bennington, VT 05257
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Other120$0$0Dec 29, 1986--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 E05 I
Other110$0$0Dec 29, 1986--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 F04
Other130$0$0Dec 29, 1986--
Dec 8, 1983Planned (H) · Complete scope, Safety#10691921$7706 viol.

Inspection #10691921

Dates

Opened
Dec 8, 1983
Closing Conference Date
Dec 8, 1983
Closed
Jan 12, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
118

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 1 repeat, 3 other-than-serious
Initial Penalties
$770
Penalties on Record
$770
Site Address
Water St, North Bennington, VT 05257
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F01
Repeat7-$560$560Dec 18, 1983--
02001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious8-$210$210Dec 18, 1983--
02001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious4-$0$0Dec 18, 1983--
030011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Other1-$0$0Dec 18, 1983--
030021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 I
Other1-$0$0Dec 8, 1983--
030031910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 III
Other1-$0$0Dec 8, 1983--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.305Electrical - Wiring Methods, Components, and Equipment6 citations · $0
1910.219Mechanical Power-Transmission Apparatus3 citations · $770
1910.304Electrical - Wiring Design and Protection2 citations · $500

Other inspected employers in North Bennington, VT