Inspection records

Jul 12, 1995Follow-Up (F) · Partial scope, Safety#126411172$00 viol.

Inspection #126411172

Dates

Opened
Jul 12, 1995
Closing Conference Date
Jul 12, 1995
Closed
Jul 12, 1995

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
47

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4948 Sr 31, Clay, NY 13041
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 5, 1995Follow-Up (F) · Partial scope, Safety#126410448$00 viol.

Inspection #126410448

Dates

Opened
Jan 5, 1995
Closing Conference Date
Jan 11, 1995
Closed
Jan 11, 1995

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
47

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4948 Sr 31, Clay, NY 13041
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 6, 1994Follow-Up (F) · Partial scope, Safety#126410869$00 viol.

Inspection #126410869

Dates

Opened
Oct 6, 1994
Closing Conference Date
Oct 6, 1994
Closed
Oct 6, 1994

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
47

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4948 Sr 31, Clay, NY 13041
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Apr 18, 1994Planned (H) · Complete scope, Safety#115875916$011 viol.

Inspection #115875916

Dates

Opened
Apr 18, 1994
Closing Conference Date
Apr 22, 1994
Closed
Jul 17, 1995

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
47

Violations and Penalties

Total Violations
11
Violation Types
11 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4948 Sr 31, Clay, NY 13041
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 D01 II
Serious15$0$0Aug 31, 1994--
010021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 I
Serious35$0$0Aug 31, 1994--
010031910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q01
Serious147$0$0Dec 31, 1994--
010041910.134
Respiratory Protection
OSHA citation code: 19100134 A02
Serious140$0$0Aug 31, 1994--
010051910.303
Electrical - General Requirements
OSHA citation code: 19100303 B02
Serious110$0$0Jul 6, 1994--
010061910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious15$0$0Jul 6, 1994--
010071910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 E01
Serious120$0$0Jul 6, 1994--
010081910.1030
Bloodborne Pathogens
OSHA citation code: 19101030 C01 IIA
Serious147$0$0Aug 31, 1994--

Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jun 2, 1989Follow-Up (F) · Partial scope, Safety#104832357$00 viol.

Inspection #104832357

Dates

Opened
Jun 2, 1989
Closing Conference Date
Jun 2, 1989
Closed
Jun 2, 1989

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
4948 Sr 31, Clay, NY 13041
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 16, 1989Planned (H) · Complete scope, Safety#104898234$04 viol.

Inspection #104898234

Dates

Opened
Feb 16, 1989
Closing Conference Date
Feb 16, 1989
Closed
Jun 16, 1989

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
4948 Sr 31, Clay, NY 13041
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Serious212$0$0Apr 28, 1989--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious112$0$0Apr 28, 1989--
020011910.106
Flammable Liquids
OSHA citation code: 19100106 D07 III
Other212$0$0Apr 28, 1989--
020021910.145
Specifications for Accident Prevention Signs and Tags
OSHA citation code: 19100145 C02
Other112$0$0Apr 28, 1989--
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1030Bloodborne Pathogens3 citations · $0
1910.305Electrical - Wiring Methods, Components, and Equipment2 citations · $0
1910.303Electrical - General Requirements2 citations · $0

Other inspected employers in CLAY, NY

All employers in CLAY →