CLERMONT STEEL FABRICATORS, LLC.
2565 OLD ST. RT. 32, BATAVIA, OH 45103 · NAICS 333994 Industrial Process Furnace and Oven Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Oct 28, 2011#331082966Oct 28, 2011Planned (H) · No Inspection scope, Health#331082966$00 viol.0 violations$0 in penalties
Inspection #331082966
Dates
- Opened
- Oct 28, 2011
- Closing Conference Date
- Not recorded
- Closed
- Oct 28, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 2565 Old State Route 32, Batavia, OH 45103
- Industry
- 333994 Industrial Process Furnace and Oven Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Feb 4, 2010#314100389Feb 4, 2010Planned (H) · Complete scope, Health#314100389$2102 viol.2 violations$210 in penalties
Inspection #314100389
Dates
- Opened
- Feb 4, 2010
- Closing Conference Date
- Mar 31, 2010
- Closed
- May 5, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $210
- Penalties on Record
- $210
- Site Address
- 2565 Old State Route 32, Batavia, OH 45103
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling27 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| 1,6-Hexamethylene Diisocyanate Homopolymer | 4 | 0 - 0.008965 | mg/m³ |
| Antimony and Compounds (as Sb) | 4 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 4 | 0 | mg/m³ |
| Cadmium | 4 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 4 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 4 | 0 | mg/m³ |
| Copper Fume (as Cu) | 4 | 0 - 0.0183622 | mg/m³ |
| Ethyl Benzene | 2 | 0.212644 - 0.325228 | ppm |
| Gravimetric DeterminationQC | 6 | 0.1482 - 5.0523 | mg/m³ |
| Hexamethylene Diisocyanate | 4 | 0 - 0.000841 | mg/m³ |
| Iron Oxide Fume | 4 | 0.6329414 - 2.2760139 | mg/m³ |
| Lead, Inorganic (as Pb) | 4 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 4 | 0.083779 - 0.3795305 | mg/m³ |
| Methylene bisphenyl isocyanate | 4 | 0 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 4 | 0 | mg/m³ |
| n-Butyl Acetate | 2 | 0.134526 - 2.409802 | ppm |
| Nickel, Metal and Insoluble compounds (as Ni) | 4 | 0 | mg/m³ |
| Particulates not otherwise regulated (Respirable Fraction) | 2 | 0.1482 - 0.2313 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 4 | 1.4733 - 5.0523 | mg/m³ |
| Polymeric MDI (PAPI) | 4 | 0 | mg/m³ |
| Sample WeightQC | 6 | 0.117 - 1.871 | mg |
| Silica, Crystalline Quartz (Respirable Fraction) | 2 | 0 | % |
| Toluene | 6 | 1.582336 - 8.698409 | ppm |
| Toluene-2,4-Diisocyanate (TDI) | 4 | 0 | mg/m³ |
| Toluene-2,6-Diisocyanate | 4 | 0 | mg/m³ |
| Trimethylbenzene (mixed isomers) | 4 | 0 - 0.105404 | ppm |
| Vanadium fume (as V2O5) | 4 | 0 | mg/m³ |
| Xylene | 6 | 0.251655 - 0.930326 | ppm |
| Zinc Oxide Fume | 4 | 0 - 0.0597115 | mg/m³ |
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1904.32 Annual Summary OSHA citation code: 19040032 A01 | Other | 1 | 2 | $210 | $210 | Apr 28, 2010 | - | - |
| 01002 | 1910.134 Respiratory Protection OSHA citation code: 19100134 C02 II | Other | 1 | 1 | $0 | $0 | Apr 28, 2010 | - | - |
Feb 4, 2010#314100355Feb 4, 2010Planned (H) · Complete scope, Safety#314100355$1,4703 viol.3 violations$1,470 in penalties
Inspection #314100355
Dates
- Opened
- Feb 4, 2010
- Closing Conference Date
- Feb 8, 2010
- Closed
- Mar 22, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 20
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $1,470
- Penalties on Record
- $1,470
- Site Address
- 2565 Old St. Rt. 32, Batavia, OH 45103
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.179 Overhead and Gantry Cranes OSHA citation code: 19100179 G01 V | Serious | 2 | 2 | $1,000 | $1,000 | Feb 26, 2010 | - | - |
| 01002 | 1910.303 OSHA citation code: 19100303 B02 | Serious | 4 | 4 | $200 | $200 | Feb 26, 2010 | - | - |
| 01003 | 1910.303 OSHA citation code: 19100303 G01 II | Serious | 1 | 1 | $270 | $270 | Feb 26, 2010 | - | - |
Jan 4, 2005#308425396Jan 4, 2005Planned (H) · Complete scope, Safety#308425396$3,0005 viol.5 violations$3,000 in penalties
Inspection #308425396
Dates
- Opened
- Jan 4, 2005
- Closing Conference Date
- Jan 10, 2005
- Closed
- Jun 28, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 59
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 serious
- Initial Penalties
- $6,250
- Penalties on Record
- $3,000
- Site Address
- 2565 Old Strt 32, Batavia, OH 45103
- Industry
- 332312 Fabricated Structural Metal Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01002 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 2 | $750 | $500 | Feb 7, 2005 | - | - |
| 01003 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 I02 | Serious | 1 | 2 | $1,250 | $500 | Feb 22, 2005 | - | - |
| 01004 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 B | Serious | 1 | 1 | $750 | $500 | Feb 14, 2005 | - | - |
| 01005 | 1910.252 General requirements OSHA citation code: 19100252 B02 IA | Serious | 1 | 1 | $2,500 | $1,000 | May 3, 2005 | - | - |
| 01006 | 1910.254 Arc Welding and Cutting OSHA citation code: 19100254 D09 III | Serious | 2 | 4 | $1,000 | $500 | Feb 7, 2005 | - | - |
Jan 4, 2005#308425354Jan 4, 2005Planned (H) · Complete scope, Health#308425354$2,62513 viol.13 violations$2,625 in penalties
Inspection #308425354
Dates
- Opened
- Jan 4, 2005
- Closing Conference Date
- Jan 10, 2005
- Closed
- Apr 19, 2005
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 59
Violations and Penalties
- Total Violations
- 13
- Violation Types
- 11 serious, 2 other-than-serious
- Initial Penalties
- $4,025
- Penalties on Record
- $2,625
- Site Address
- 2565 Old State Route 32, Batavia, OH 45103
- Industry
- 332999 All Other Miscellaneous Fabricated Metal Product Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Chemical Exposure Sampling14 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Antimony and Compounds (as Sb) | 6 | 0 | mg/m³ |
| Beryllium and Beryllium Compounds (as Be) | 6 | 0 | mg/m³ |
| Cadmium | 6 | 0 | mg/m³ |
| Chromium, Metal and Insoluble Salts | 6 | 0 | mg/m³ |
| Cobalt, Metal, Dust and Fume (as Co) | 6 | 0 | mg/m³ |
| Copper Fume (as Cu) | 6 | 0 - 0.0152581 | mg/m³ |
| Gravimetric DeterminationQC | 6 | 2.3643 - 11.8877 | mg/m³ |
| Iron Oxide Fume | 6 | 0.8183597 - 4.6333556 | mg/m³ |
| Lead, Inorganic (as Pb) | 6 | 0 | mg/m³ |
| Manganese Fume (as Mn) | 6 | 0.1217486 - 0.9080592 | mg/m³ |
| Molybdenum (as Mo), Insoluble Compounds (Total Dust) | 6 | 0 | mg/m³ |
| Nickel, Metal and Insoluble compounds (as Ni) | 6 | 0 | mg/m³ |
| Particulates not otherwise regulated (Total Dust) | 6 | 2.3643 - 11.8877 | mg/m³ |
| Sample WeightQC | 6 | 1.248 - 4.698 | mg |
| Vanadium fume (as V2O5) | 6 | 0 | mg/m³ |
| Zinc Oxide Fume | 6 | 0 | mg/m³ |
Violations
Violation list (10 of 13 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 K01 | Serious | 35 | 35 | $875 | $875 | Apr 1, 2005 | - | - |
| 01001B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 L01 | Serious | 1 | 35 | $0 | $0 | Jan 26, 2005 | - | - |
| 01002A | 1910.151 Medical Services and First Aid OSHA citation code: 19100151 C | Serious | 1 | 2 | $875 | $875 | Feb 16, 2005 | - | - |
| 01002B | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Serious | 1 | 1 | $0 | $0 | Jan 21, 2005 | - | - |
| 01003 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G02 | Other | 50 | 50 | $525 | $0 | Feb 16, 2005 | - | - |
| 01004A | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Serious | 1 | 2 | $875 | $875 | Jan 19, 2005 | - | - |
| 01004B | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Serious | 1 | 50 | $0 | $0 | May 3, 2005 | - | - |
| 01004C | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 I | Serious | 1 | 2 | $0 | $0 | May 3, 2005 | - | - |
| 01004D | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Serious | 2 | 2 | $0 | $0 | Jan 19, 2005 | - | - |
| 01004E | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Serious | 2 | 2 | $0 | $0 | Jan 19, 2005 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 13 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 2005 to 2011. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Machinery Manufacturing, 17,988 employers with OSHA inspections. Arithmetic from DOL records.