Skip to content
SafetyRecord logoSafetyRecord
COLUMBIA PACKING CO INC
$2,074
penalties
20
viol.
5
insp.

COLUMBIA PACKING CO INC

2807 E ELEVENTH ST, DALLAS, TX 75203

Inspections
5
Feb 1977 to Jun 1998 · 3 safety, 2 health
Violations
20
across 5 inspections
Penalties on record
$2,074
latest amounts in DOL records
By classification
Serious 15Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 9, 1998Follow-Up (F) · Partial scope, Health#300554961$00 viol.

Inspection #300554961

Dates

Opened
Jun 9, 1998
Closing Conference Date
Jun 9, 1998
Closed
Sep 14, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
68

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2807 E. 11th, Dallas, TX 75203
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 6, 1998Planned (H) · Partial scope, Health#300554391$1,2609 viol.

Inspection #300554391

Dates

Opened
Mar 6, 1998
Closing Conference Date
Mar 6, 1998
Closed
Sep 14, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
68

Violations and Penalties

Total Violations
9
Violation Types
9 serious
Initial Penalties
$4,200
Penalties on Record
$1,260
Site Address
2807 E. 11th, Dallas, TX 75203
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
OSHA citation code: 19100036 D01
Serious14$700$420Apr 24, 1998--
01002A1910.38
OSHA citation code: 19100038 A01
Serious168$700$420Apr 10, 1998--
01002B1910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q01
Serious168$0$0Apr 10, 1998--
010031910.120
Hazardous Waste Operations and Emergency Response
OSHA citation code: 19100120 Q06 III
Serious11$700$0Apr 10, 1998--
010041910.134
Respiratory Protection
OSHA citation code: 19100134 B07
Serious12$700$420Mar 30, 1998--
010051910.151
Medical Services and First Aid
OSHA citation code: 19100151 C
Serious12$700$0Apr 1, 1998--
01006A1910.165
Employee Alarm Systems
OSHA citation code: 19100165 B02
Serious230$700$0Apr 24, 1998--
01006B1910.165
Employee Alarm Systems
OSHA citation code: 19100165 B03
Serious268$0$0Apr 24, 1998--
01006C1910.165
Employee Alarm Systems
OSHA citation code: 19100165 D03
Serious168$0$0Apr 24, 1998--

Failure to Abate Penalties1 citation, $100 in FTA penalties on record

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 1 citation issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01006C#300554961Jul 8, 1998$100--
Sep 26, 1991Planned (H) · Complete scope, Safety#107554230$8147 viol.

Inspection #107554230

Dates

Opened
Sep 26, 1991
Closing Conference Date
Sep 27, 1991
Closed
Oct 23, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
44

Violations and Penalties

Total Violations
7
Violation Types
6 serious, 1 other-than-serious
Initial Penalties
$1,625
Penalties on Record
$814
Site Address
2807 E. 11th, Dallas, TX 75203
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.24
OSHA citation code: 19100024 H
Serious22$375$188Oct 28, 1991--
01001B1910.27
OSHA citation code: 19100027 B01 II
Serious21$0$0Oct 28, 1991--
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious15$375$188Oct 28, 1991--
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious15$0$0Oct 28, 1991--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C02 I
Serious15$375$188Oct 28, 1991--
010041910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Serious45$500$250Oct 28, 1991--
020011910.22
OSHA citation code: 19100022 A02
Other12$0$0Oct 28, 1991--
Nov 28, 1984Planned (H) · Records Only scope, Safety#1536333$00 viol.

Inspection #1536333

Dates

Opened
Nov 28, 1984
Closing Conference Date
Nov 28, 1984
Closed
Nov 28, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
60

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2807 E Eleventh St, Dallas, TX 75203
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Feb 22, 1977Planned (H) · Complete scope, Safety#16486441$04 viol.

Inspection #16486441

Dates

Opened
Feb 22, 1977
Closing Conference Date
Feb 22, 1977
Closed
Mar 15, 1977

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
37

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2807 E Eleventh, Dallas, TX 75203
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011904.2
OSHA citation code: 19040002 A
Other1-$0$0Feb 27, 1977--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other2-$0$0Mar 28, 1977--
010031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other2-$0$0Mar 28, 1977--
010041910.309
OSHA citation code: 19100309 B 041037
Other3-$0$0Mar 3, 1977--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus5 citations · $376
1910.165Employee Alarm Systems3 citations · $0
1910.120Hazardous Waste Operations and Emergency Response2 citations · $0