Skip to content
SafetyRecord logoSafetyRecord
CRAM ROOFING COMPANY, INC.
$12,125
penalties
15
viol.
2
insp.

CRAM ROOFING COMPANY, INC.

BLDG 1281, C.C. NAVAL AIR STATION, Corpus Christi, TX 78419

Inspections
2
Jan 1999 to Mar 1999 · 1 safety, 1 health
Violations
15
across 2 inspections
Penalties on record
$12,125
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Mar 4, 1999Referral (C) · Partial scope, Safety#302100623$12,12512 viol.

Inspection #302100623

Dates

Opened
Mar 4, 1999
Closing Conference Date
Mar 4, 1999
Closed
Feb 18, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
13
Related Activity
1 referral

Violations and Penalties

Total Violations
12
Violation Types
11 serious, 1 other-than-serious
Initial Penalties
$48,750
Penalties on Record
$12,125
Site Address
Bldg 1281, C.c. Naval Air Station, Corpus Christi, TX 78419
Industry
Not classified in OSHA's inspection record.

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (12 of 12 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B10
Serious113$2,500$1,875May 8, 1999--
010021926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 C
Serious113$1,250$625May 8, 1999--
010031926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious113$1,250$625May 14, 1999--
01004A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 F01 I
Serious113$2,500$1,250May 8, 1999--
01004B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 F01 III
Serious113$0$0May 8, 1999--
01005A1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 F02 I
Serious113$2,500$500May 8, 1999--
01005B1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 F02 II
Serious113$0$0May 8, 1999--
01005C1926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 F02 V
Serious113$0$0May 8, 1999--
010061926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 F03
Serious113$2,500$1,500May 8, 1999--
01007A1926.1053
Ladders (Construction)
OSHA citation code: 19261053 B01
Serious113$1,250$750May 8, 1999--
020011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B03
Serious213$35,000$5,000May 8, 1999--
030011904.2
OSHA citation code: 19040002 A
Other135$0$0May 8, 1999--
Jan 20, 1999Unprogrammed Related (G) · Partial scope, Health#302100292$03 viol.

Inspection #302100292

Dates

Opened
Jan 20, 1999
Closing Conference Date
Jan 21, 1999
Closed
Sep 8, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
Bldg 1281, C.c. Naval Air Station, Corpus Christi, TX 78419
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C01 III
Other12$0$0May 22, 1999--
01001B1910.134
Respiratory Protection
OSHA citation code: 19100134 C01 IX
Other12$0$0May 22, 1999--
01001C1910.134
Respiratory Protection
OSHA citation code: 19100134 C03
Other12$0$0May 22, 1999--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.502Fall Protection Systems Criteria and Practices6 citations · $3,250
1910.134Respiratory Protection3 citations · $0
1926.501Fall Protection - Duty to Have Fall Protection3 citations · $7,500

Other inspected employers in Corpus Christi, TX