Skip to content
SafetyRecord logoSafetyRecord
DAVID LOUIS YORK
$3,455
penalties
9
viol.
3
insp.

DAVID LOUIS YORK

#6 QUELAH LANE, SUNRIVER, OR 97707

Inspections
3
Aug 1995 to Jun 2008 · 3 safety, 0 health
Violations
9
across 3 inspections
Penalties on record
$3,455
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 1Other 2

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 19, 2008Planned (H) · Partial scope, Safety#312259260$6251 viol.

Inspection #312259260

Dates

Opened
Jun 19, 2008
Closing Conference Date
Jun 19, 2008
Closed
Nov 17, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
1
Violation Types
1 serious
Initial Penalties
$625
Penalties on Record
$625
Site Address
57235 River Rd, Sunriver, OR 97707
Industry
236115 New Single-Family Housing Construction (except For-Sale Builders)

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001703.1501Serious11$625$625Jun 19, 2008--
Mar 1, 1996Accident (A) · Partial scope, Safety#126686435$2,0002 viol.

Inspection #126686435

Dates

Opened
Mar 1, 1996
Closing Conference Date
Mar 19, 1996
Contested
Apr 29, 1996
Final Order
May 22, 1996
Closed
Sep 4, 1996

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
18

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$2,800
Penalties on Record
$2,000
Site Address
#6 Foursome Ln, Sunriver, OR 97709
Industry
Not classified in OSHA's inspection record.

Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.

Incident Investigation Summaries

Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.

HospitalizationMar 1, 1996

Employee injured in fall from roof

Injury: FractureBody part: BackSource: Bodily MotionEvent: Fall (From Elevation)

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B11
Serious11$2,500$1,700Apr 24, 1996Apr 29, 1996May 22, 1996
01002701076001
OSHA citation code: 701076001 A
Serious11$300$300Apr 24, 1996Apr 29, 1996May 22, 1996
Aug 4, 1995Planned (H) · Complete scope, Safety#126691047$8306 viol.

Inspection #126691047

Dates

Opened
Aug 4, 1995
Closing Conference Date
Aug 4, 1995
Closed
Sep 4, 1996

Inspection

Advance Notice
No
Owner Type
State government
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
6
Violation Types
3 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$830
Penalties on Record
$830
Site Address
#6 Quelah Lane, Sunriver, OR 97707
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious12$180$180Aug 4, 1995--
010021926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 IIIG
Serious12$270$270Sep 11, 1995--
010031926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious12$180$180Aug 4, 1995--
020041926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 III
Repeat12$200$200Aug 4, 1995--
030051926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 IIIC
Other12$0$0Sep 11, 1995--
030061926.1052
Stairways (Construction)
OSHA citation code: 19261052 C01 I
Other12$0$0Aug 4, 1995--
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.404Electrical - Wiring Design and Protection (Construction)3 citations · $450
1926.501Fall Protection - Duty to Have Fall Protection2 citations · $1,880
1926.405Electrical - Wiring Methods (Construction)1 citation · $200

Industry comparison

BLS 2024 survey: residential building construction reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 8.5%; NAICS 2361 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in SUNRIVER, OR