DECO PLATE MFG CO
395 DEMILLE RD, LAPEER, MI 48446
NAICS 332813: Electroplating, Plating, Polishing, Anodizing, and Coloring - Records current through Sep 23, 2009
DECO PLATE MFG CO has had 11 OSHA inspections since Mar 13, 1991, resulting in 108 violations and $23,486 in penalties on record.
As reported in the U.S. Department of Labor OSHA enforcement database. Having inspection records is common for businesses in regulated industries. Penalty amounts may differ from final amounts after settlement or judicial review.
- A total of 11 OSHA inspections have been documented at this location.
- OSHA last inspected this location on September 23, 2009. That inspection has since been closed.
- This establishment has OSHA records dating from 1991 to 2009, a span of 18 years.
- Among the 108 total violations at this location, 48 received a Serious classification, representing 44% of the total.
- OSHA has cited 3 repeat violations at this location. Repeat citations indicate that a substantially similar violation was previously cited at this employer.
- No violations at this establishment have been classified as willful.
- All documented inspections at this establishment are listed as closed in OSHA's system.
Data sourced from the U.S. Department of Labor OSHA enforcement database. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conferences, settlements, or adjudication. Having an inspection record is common in regulated industries and does not by itself indicate unsafe conditions. This is not an official OSHA resource and does not constitute legal advice.
Most Cited Standards10 standards
Ranked by citation count across this employer's inspections on record. Counts and penalties are exact sums from violations linked to those inspections.
| Standard | Citations | Penalties |
|---|---|---|
| 1910.305Electrical - Wiring Methods, Components, and Equipment | 7 | $650 |
| 1910.1200Hazard Communication | 7 | $2,100 |
| 1910.146Permit-Required Confined Spaces | 6 | $750 |
| 4081331201 | 4 | $2,550 |
| 4081003409 | 3 | $1,313 |
| 4081111502 | 3 | $0 |
| 1910.147Control of Hazardous Energy (Lockout/Tagout) | 3 | $1,075 |
| 4080.1011 | 3 | $925 |
| 4081021302 | 3 | $1,313 |
| 4081001503 | 2 | $375 |
Enforcement Timeline11 inspections, 1991-2009
Each row is one OSHA inspection on record. Markers show openings, contest activity, final orders, and closures. Full record detail for each inspection is listed below.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Inspection Records1991 - 2009
Full record for each inspection on file. Includes type, scope, violations on record, and current penalty.
| ID | Opened | Type | Scope | Viol. | Penalties |
|---|---|---|---|---|---|
| #312065642 | Sep 23, 2009 | Planned | Complete | 20 | $5,880 |
| #308845205 | Feb 2, 2007 | Complaint | Partial | 1 | $0 |
| #125136895 | Oct 2, 2003 | Referral | Partial | 8 | $413 |
| #127171288 | Jun 26, 2003 | Planned | Complete | 31 | $5,643 |
| #125150508 | Nov 30, 1998 | Referral | Partial | 3 | $925 |
| #114530066 | Jan 15, 1997 | Complaint | Partial | 2 | $0 |
| #114527484 | May 21, 1996 | Complaint | Partial | 0 | $0 |
| #124913690 | Apr 3, 1996 | Planned | Complete | 20 | $3,375 |
| #125081992 | Nov 3, 1994 | Planned | Complete | 8 | $3,450 |
| #114860588 | Nov 9, 1993 | Planned | Complete | 12 | $3,200 |
| #108018649 | Mar 13, 1991 | Referral | Partial | 3 | $600 |
About This Industry
NAICS 332813: Coating, Engraving, Heat Treating, and Allied Activities / Manufacturing
This industry group comprises establishments that perform metal coating, engraving, heat treating, and polishing for the trade. Services include electroplating, anodizing, powder coating, and thermal spray coating.
Common workplace hazards include exposure to hexavalent chromium, cadmium, and other toxic metals in plating solutions, chemical burns from acids and caustics, and thermal burns from heat treating furnaces. Workers may also face risks from confined space entry in plating tanks and ventilation deficiencies.
Data Source and Methodology
Data synced dailyData on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.