Skip to content
SafetyRecord logoSafetyRecord
DELPHI AUTOMOTIVE SYSTEMS
$61,500
Penalties
18
Violations
6
Inspections

DELPHI AUTOMOTIVE SYSTEMS

342 PERRY HOUSE ROAD, FITZGERALD, GA 31750

NAICS 335911: Storage Battery Manufacturing - Records current through Jul 23, 2002

DELPHI AUTOMOTIVE SYSTEMS has had 6 OSHA inspections since Nov 19, 1990, resulting in 18 violations and $61,500 in penalties on record.

As reported in the U.S. Department of Labor OSHA enforcement database. Having inspection records is common for businesses in regulated industries. Penalty amounts may differ from final amounts after settlement or judicial review.

7Serious
0Willful
2Repeat
9Other
Overview
  • A total of 6 OSHA inspections have been documented at this location.
  • The last documented OSHA inspection at this establishment was opened on July 23, 2002. That inspection has since been closed.
  • This establishment has OSHA records dating from 1990 to 2002, a span of 12 years.
  • Serious violations account for 39% of the 18 total citations at this location (7 out of 18).
  • OSHA cited 2 violations classified as repeat at this location. Repeat status means a substantially similar hazard was previously cited at this employer.
  • No violations at this establishment have been classified as willful.
  • Each inspection at this location has a recorded close date.

Data sourced from the U.S. Department of Labor OSHA enforcement database. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conferences, settlements, or adjudication. Having an inspection record is common in regulated industries and does not by itself indicate unsafe conditions. This is not an official OSHA resource and does not constitute legal advice.

Industry Comparison vs. Electrical Equipment, Appliance, and Component Manufacturing
Violations per Inspection
3.0Near avg
Industry avg: 3.0 (4,524 employers)
Penalties per Inspection
$10,250Above avg
Industry avg: $2,293 (4,524 employers)
Most Cited Standards5 standards

Ranked by citation count across this employer's inspections on record. Counts and penalties are exact sums from violations linked to those inspections.

StandardCitationsPenalties
1910.1025Lead11$51,750
1910.147Control of Hazardous Energy (Lockout/Tagout)4$7,600
1910.95Occupational Noise Exposure1$750
1910.212General Requirements for All Machines (Machine Guarding)1$1,400
1910.1200Hazard Communication1$0
Enforcement Timeline6 inspections, 1990-2002
Rotate your device to landscape to view the enforcement timeline visually. The full inspection records list is below.

Each row is one OSHA inspection on record. Markers show openings, contest activity, final orders, and closures. Full record detail for each inspection is listed below.

Inspection
#303772008
Follow-Up
#303767719
Monitoring
#303767420
Follow-Up
#300652237
Complaint
#109005249
Planned
#106215031
Other
19901991199219931994199519961997199819992000200120022003200420052006200720082009201020112012201320142015201620172018201920202021202220232024202520262027NOW
Penalty on record
$0
$0
$60,000
$0
$1,500
$0
OpenedOn recordContest recordedFinal order recordedClosedNo close date in feed

Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).

Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.

Inspection Records1990 - 2002

Full record for each inspection on file. Includes type, scope, violations on record, and current penalty.

Chemical Exposure Sampling

OSHA collected 33 air monitoring samples across 3 inspections, testing for 1 substance. These include personal breathing zone and area air monitoring samples collected during OSHA inspections. View individual inspection pages for detailed sample results and exposure measurements.

Source: OSHA chemical exposure sampling data (OSHA Information System). Includes personal and area air monitoring samples only. Linked via inspection number (exact government key).

About This Industry

NAICS 335911: Other Electrical Equipment and Component Manufacturing / Manufacturing

This industry group comprises establishments manufacturing electrical equipment not classified elsewhere, including batteries, communication and energy wire, wiring devices, and carbon and graphite products.

Common workplace hazards include electrical shock and arc flash, exposure to lead and acid in battery manufacturing, and chemical exposure from insulation and coating materials. Workers may also face machine guarding hazards and ergonomic injuries from repetitive assembly tasks.

Other Inspected Employers in FITZGERALD, GA

Data Source and Methodology

Data synced daily

Data on this page comes from the U.S. Department of Labor's OSHA enforcement database, accessed via the DOL public data API. Records are updated daily. We strive for accuracy, but errors in data processing or establishment grouping are possible. Penalty amounts reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts after informal conference, settlement, or judicial review. Company pages group inspection records by normalized employer name, city, and state as reported in OSHA records. That grouping is deterministic and non-fuzzy, but it is not a universal legal-entity identifier. If you believe any record is inaccurate, please report it and we will investigate. This product uses the DOL Data API but is not endorsed or certified by the DOL. For official and authoritative records, visit osha.gov.