DONNER PLUMBING & HEATING
WEST MESA HIGH, ALBUQUERQUE, NM 87107
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 22, 2010#314489485Mar 22, 2010Planned (H) · Complete scope, Safety#314489485$00 viol.0 violations$0 in penalties
Inspection #314489485
Dates
- Opened
- Mar 22, 2010
- Closing Conference Date
- Mar 22, 2010
- Closed
- May 14, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 10
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 2500 Central Se, Albuquerque, NM 87106
- Industry
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jan 25, 2002#303408728Jan 25, 2002Planned (H) · Complete scope, Safety#303408728$00 viol.0 violations$0 in penalties
Inspection #303408728
Dates
- Opened
- Jan 25, 2002
- Closing Conference Date
- Jan 25, 2002
- Closed
- Feb 26, 2002
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 36
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1117 Stanford Ne, Albuquerque, NM 87106
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jan 26, 1994#103622171Jan 26, 1994Programmed Related (I) · Partial scope, Safety#103622171$2501 viol.1 violation$250 in penalties
Inspection #103622171
Dates
- Opened
- Jan 26, 1994
- Closing Conference Date
- Jan 26, 1994
- Contested
- Apr 26, 1994
- Final Order
- Sep 21, 1994
- Closed
- Jan 23, 1995
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 serious
- Initial Penalties
- $1,750
- Penalties on Record
- $250
- Site Address
- 9904 Montgomery Ne, El Dorado Station, Albuquerque, NM 87111
- Industry
- Not classified in OSHA's inspection record.
Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.102 Eye and Face Protection (Construction) OSHA citation code: 19260102 A01 | Serious | 1 | 1 | $1,750 | $250 | Apr 8, 1994 | Apr 26, 1994 | Sep 21, 1994 |
Aug 14, 1989#108499062Aug 14, 1989Planned (H) · Complete scope, Safety#108499062$00 viol.0 violations$0 in penalties
Inspection #108499062
Dates
- Opened
- Aug 14, 1989
- Closing Conference Date
- Aug 14, 1989
- Closed
- Oct 24, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 5
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- West Mesa High, Albuquerque, NM 87107
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Aug 9, 1989#108501255Aug 9, 1989Planned (H) · Complete scope, Safety#108501255$00 viol.0 violations$0 in penalties
Inspection #108501255
Dates
- Opened
- Aug 9, 1989
- Closing Conference Date
- Aug 9, 1989
- Closed
- Oct 24, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 2
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Valley High, Albuquerque, NM 87107
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Oct 2, 1973#16928715Oct 2, 1973Follow-Up (F) · Complete scope, Safety#16928715$00 viol.0 violations$0 in penalties
Inspection #16928715
Dates
- Opened
- Oct 2, 1973
- Closing Conference Date
- Oct 2, 1973
- Closed
- Mar 10, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Not displayed
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 4920 Menaul Avenue Ne, Albuquerque, NM 87110
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Sep 11, 1973#16933632Sep 11, 1973Planned (H) · Complete scope, Safety#16933632$05 viol.5 violations$0 in penalties
Inspection #16933632
Dates
- Opened
- Sep 11, 1973
- Closing Conference Date
- Sep 11, 1973
- Closed
- Mar 10, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Not displayed
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 5 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 4920 Menaul Avenue Ne, Albuquerque, NM 87110
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01002 | 1926.350 Gas Welding and Cutting OSHA citation code: 19260350 A07 | Other | 1 | - | $0 | $0 | Sep 21, 1973 | - | - |
| 01003 | 1926.352 Fire Prevention (Welding) OSHA citation code: 19260352 D | Other | 1 | - | $0 | $0 | Sep 21, 1973 | - | - |
| 01004 | 1926.450 Scaffolding - Scope, Application, and Definitions OSHA citation code: 19260450 A09 | Other | 1 | - | $0 | $0 | Sep 21, 1973 | - | - |
| 01005 | 1926.450 Scaffolding - Scope, Application, and Definitions OSHA citation code: 19260450 A10 | Other | 1 | - | $0 | $0 | Sep 21, 1973 | - | - |
| 01006 | 1903.2 Posting of Notices; Availability of the Act, Regulations and Applicable Standards OSHA citation code: 19030002 A | Other | 1 | - | $0 | $0 | Sep 21, 1973 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
7 inspections, 1973 to 2010. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
BLS 2024 survey: plumbing, heating, and air-conditioning contractors reported 3.0 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.2%; NAICS 23822 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source