EAST NOBLE SCHOOL CORPORATION
$0
penalties
19
viol.
13
insp.

EAST NOBLE SCHOOL CORPORATION

(WAYNE CENTER ELEM) C R 900 NORTH AT C R 900 EAST, Kendallville, IN 46755

Inspections
13
Jul 1984 to Oct 1990 · 13 safety, 0 health
Violations
19
across 13 inspections
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 16Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jul 9, 1984Planned (H) · Complete scope, Safety#14683189$03 viol.

Inspection #14683189

Dates

Opened
Jul 9, 1984
Closing Conference Date
Jul 9, 1984
Closed
Jan 3, 1985

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
22

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
900 North And 900 West, Kendallville, IN 46755
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Wiring design and protection
OSHA citation code: 19100304 F05 V
Serious12$0$0Jul 26, 1984--
02001A1910.106
OSHA citation code: 19100106 G03 IVD
Other14$0$0Aug 20, 1984--
02001B1910.106
OSHA citation code: 19100106 G08
Other14$0$0Aug 20, 1984--
Jul 6, 1984Planned (H) · Complete scope, Safety#14683262$03 viol.

Inspection #14683262

Dates

Opened
Jul 6, 1984
Closing Conference Date
Jul 6, 1984
Closed
Jan 3, 1985

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
45

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
302 Harding St, Kendallville, IN 46755
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious12$0$0Aug 20, 1984--
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 A03 I
Serious12$0$0Aug 20, 1984--
010021910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious12$0$0Jul 26, 1984--
Jul 6, 1984Planned (H) · Complete scope, Safety#14683254$05 viol.

Inspection #14683254

Dates

Opened
Jul 6, 1984
Closing Conference Date
Jul 6, 1984
Closed
Jan 11, 1985

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
Yes
Number of Employees
82

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
South Garden St, Kendallville, IN 46755
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious11$0$0Sep 19, 1984--
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious31$0$0Aug 20, 1984--
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious21$0$0Aug 20, 1984--
01002C1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Aug 20, 1984--
010031910.304
Wiring design and protection
OSHA citation code: 19100304 F04
Serious11$0$0Jul 26, 1984--

Failure to Abate Penalties3 citations

OSHA's enforcement record shows Failure to Abate (FTA) activity recorded against 3 citations issued in this inspection. An FTA penalty is assessed during a follow-up inspection when OSHA's records indicate a previously cited hazard was not corrected by the abatement date. Each row below shows the FTA fields published on the original citation record: the follow-up inspection number, the FTA issuance date, the FTA penalty amount, and any FTA contest or final order date on record.

CitationFTA InspectionFTA IssuanceFTA PenaltyFTA ContestFTA Final Order
01002A#2760817Jan 2, 1985---
01002B#2760817Jan 2, 1985---
01002C#2760817Jan 2, 1985---
Inspections 11 to 13 of 13, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: U.S. Department of Labor OSHA enforcement data, violations table fields fta_insp_nr, fta_issuance_date, fta_penalty, fta_contest_date, fta_final_order_date. The FTA follow-up inspection is linked via fta_insp_nr to the inspection activity number (exact government key). When the follow-up inspection is not currently on record in SafetyRecord, the inspection number is shown without a link.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus7 citations · $0
1910.304Wiring design and protection6 citations · $0
1910.1062 citations · $0

Other inspected employers in Kendallville, IN