May 10, 1989#107991077May 10, 1989Planned (H) · Complete scope, Safety#107991077$05 viol.5 violations$0 in penalties
Inspection #107991077
Dates
- Opened
- May 10, 1989
- Closing Conference Date
- May 10, 1989
- Closed
- Sep 22, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 55
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 1 serious, 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- (eastern Jr & Sr Hs) Cr 59 & Blue River Road, Pekin, IN 47165
- Industry
- 611110 Elementary and Secondary Schools
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 OSHA citation code: 19100106 E02 IIB | Serious | 1 | 5 | $0 | $0 | Jul 7, 1989 | - | - |
| 02001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Other | 1 | 3 | $0 | $0 | Jul 7, 1989 | - | - |
| 02002 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 V | Other | 1 | 12 | $0 | $0 | Jul 7, 1989 | - | - |
| 02003 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G01 III | Other | 2 | 12 | $0 | $0 | Jul 7, 1989 | - | - |
| 02004 | 1910.306 Specific purpose equipment and installations OSHA citation code: 19100306 J05 | Other | 1 | 4 | $0 | $0 | Jul 7, 1989 | - | - |
May 10, 1989#107991044May 10, 1989Planned (H) · Complete scope, Safety#107991044$07 viol.7 violations$0 in penalties
Inspection #107991044
Dates
- Opened
- May 10, 1989
- Closing Conference Date
- May 10, 1989
- Closed
- May 30, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 7 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- (admin Bldg) County Road 59 & Blue River Road, Pekin, IN 47165
- Industry
- 921110
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 400.302 | Other | 1 | 100 | $0 | $0 | Jul 7, 1989 | - | - |
| 01002 | 400.402 | Other | 1 | 100 | $0 | $0 | Jul 7, 1989 | - | - |
| 01003 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E02 | Other | 1 | 100 | $0 | $0 | Jul 7, 1989 | - | - |
| 01004 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 V | Other | 1 | 2 | $0 | $0 | Jul 7, 1989 | - | - |
| 01005 | 1910.1200 Hazard Communication OSHA citation code: 19101200 E01 | Other | 1 | 100 | $0 | $0 | Aug 18, 1989 | - | - |
| 01006 | 1910.1200 Hazard Communication OSHA citation code: 19101200 G01 | Other | 1 | 100 | $0 | $0 | Aug 18, 1989 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jul 27, 1987#104051248Jul 27, 1987Planned (H) · Complete scope, Safety#104051248$02 viol.2 violations$0 in penalties
Inspection #104051248
Dates
- Opened
- Jul 27, 1987
- Closing Conference Date
- Jul 27, 1987
- Closed
- Sep 17, 1987
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 62
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 1 serious, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- County Rd 59, Pekin, IN 47165
- Industry
- 611110 Elementary and Secondary Schools
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F 4 | Serious | 3 | 2 | $0 | $0 | Aug 31, 1987 | - | - |
| 02001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Other | 1 | 2 | $0 | $0 | Aug 31, 1987 | - | - |
Mar 5, 1986#2670735Mar 5, 1986Planned (H) · Complete scope, Safety#2670735$03 viol.3 violations$0 in penalties
Inspection #2670735
Dates
- Opened
- Mar 5, 1986
- Closing Conference Date
- Mar 5, 1986
- Closed
- Apr 29, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 1
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 2 serious, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- C.r. #59, Pekin, IN 47165
- Industry
- 611110 Elementary and Secondary Schools
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 OSHA citation code: 19100023 C01 | Serious | 1 | 1 | $0 | $0 | May 21, 1986 | - | - |
| 01002 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F04 | Serious | 2 | 1 | $0 | $0 | Mar 27, 1986 | - | - |
| 02001 | 1910.22 OSHA citation code: 19100022 D01 | Other | 1 | 1 | $0 | $0 | May 21, 1986 | - | - |
Mar 5, 1986#2670727Mar 5, 1986Planned (H) · Complete scope, Safety#2670727$00 viol.0 violations$0 in penalties
Inspection #2670727
Dates
- Opened
- Mar 5, 1986
- Closing Conference Date
- Mar 5, 1986
- Closed
- Mar 24, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 50
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- C.r. #59, Pekin, IN 47165
- Industry
- 611110 Elementary and Secondary Schools
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Mar 5, 1986#2670719Mar 5, 1986Planned (H) · Complete scope, Safety#2670719$06 viol.6 violations$0 in penalties
Inspection #2670719
Dates
- Opened
- Mar 5, 1986
- Closing Conference Date
- Mar 5, 1986
- Closed
- Apr 29, 1986
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 62
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 4 serious, 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Cr 59, Pekin, IN 47165
- Industry
- 611110 Elementary and Secondary Schools
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 1 | $0 | $0 | Apr 1, 1986 | - | - |
| 01002 | 1910.304 Wiring design and protection OSHA citation code: 19100304 E01 IV | Serious | 2 | 1 | $0 | $0 | Apr 1, 1986 | - | - |
| 01003A | 1910.304 Wiring design and protection OSHA citation code: 19100304 F04 | Serious | 3 | 65 | $0 | $0 | Apr 11, 1986 | - | - |
| 01003B | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 V | Serious | 1 | 6 | $0 | $0 | Apr 21, 1986 | - | - |
| 02001 | 1910.25 OSHA citation code: 19100025 D01 X | Other | 2 | 4 | $0 | $0 | Mar 27, 1986 | - | - |
| 02002 | 1910.303 OSHA citation code: 19100303 F | Other | 1 | 2 | $0 | $0 | Apr 1, 1986 | - | - |
Jan 23, 1985#2758472Jan 23, 1985Planned (H) · Complete scope, Safety#2758472$09 viol.9 violations$0 in penalties
Inspection #2758472
Dates
- Opened
- Jan 23, 1985
- Closing Conference Date
- Jan 23, 1985
- Closed
- Mar 11, 1985
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 62
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 5 serious, 4 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- County Rd 59, Pekin, IN 47165
- Industry
- 611110 Elementary and Secondary Schools
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.304 Wiring design and protection OSHA citation code: 19100304 F04 | Serious | 5 | 3 | $0 | $0 | Feb 15, 1985 | - | - |
| 01001B | 1910.304 Wiring design and protection OSHA citation code: 19100304 F05 V | Serious | 1 | 2 | $0 | $0 | Feb 15, 1985 | - | - |
| 01002A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 2 | $0 | $0 | Mar 4, 1985 | - | - |
| 01002B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E01 I | Serious | 1 | 2 | $0 | $0 | Mar 4, 1985 | - | - |
| 01003 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 1 | 2 | $0 | $0 | Mar 4, 1985 | - | - |
| 02001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Other | 3 | 2 | $0 | $0 | Mar 4, 1985 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jan 23, 1985#2758464Jan 23, 1985Planned (H) · Complete scope, Safety#2758464$03 viol.3 violations$0 in penalties
Inspection #2758464
Dates
- Opened
- Jan 23, 1985
- Closing Conference Date
- Jan 23, 1985
- Closed
- Mar 11, 1985
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- Yes
- Number of Employees
- 50
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- County Rd 59, Pekin, IN 47165
- Industry
- 611110 Elementary and Secondary Schools
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.304 Wiring design and protection OSHA citation code: 19100304 F04 | Serious | 2 | 2 | $0 | $0 | Jan 29, 1985 | - | - |
| 01002A | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Serious | 1 | 2 | $0 | $0 | Feb 11, 1985 | - | - |
| 01002B | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E01 I | Serious | 1 | 2 | $0 | $0 | Feb 11, 1985 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
18 inspections, 1985 to 1991. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Educational Services, 15,828 employers with OSHA inspections. Arithmetic from DOL records.