Skip to content
SafetyRecord logoSafetyRecord
ELES BROTHERS READY MIX CONCRETE
$3,495
penalties
14
viol.
4
insp.

ELES BROTHERS READY MIX CONCRETE

1000 THOMPSON RUN ROAD, Monroeville, PA 15146NAICS 327320 Ready-Mix Concrete Manufacturing

Inspections
4
Jan 2000 to May 2013 · 0 safety, 4 health
Violations
14
across 4 inspections
Penalties on record
$3,495
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 17, 2013Planned (H) · No Inspection scope, Health#339074320$00 viol.

Inspection #339074320

Dates

Opened
May 17, 2013
Closing Conference Date
May 17, 2013
Closed
May 20, 2013

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
11

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1000 Thompson Run Road, Monroeville, PA 15146
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

May 17, 2007Planned (H) · Complete scope, Health#310289947$1,9956 viol.

Inspection #310289947

Dates

Opened
May 17, 2007
Closing Conference Date
Jul 9, 2007
Closed
Jan 10, 2008

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
6
Violation Types
6 serious
Initial Penalties
$2,850
Penalties on Record
$1,995
Site Address
1000 Thompson Run Road, Monroeville, PA 15146
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 A08
Serious11$450$315Jul 17, 2007--
010021910.24
OSHA citation code: 19100024 F
Serious11$450$315Jul 17, 2007--
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$450$315Jul 30, 2007--
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Jul 30, 2007--
010041910.303
OSHA citation code: 19100303 B02
Serious11$750$525Jul 30, 2007--
010051910.303
OSHA citation code: 19100303 G02 I
Serious41$750$525Jul 17, 2007--
Feb 26, 2002Complaint (B) · Partial scope, Health#305101560$1,5005 viol.

Inspection #305101560

Dates

Opened
Feb 26, 2002
Closing Conference Date
Apr 23, 2002
Closed
Jun 12, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8
Related Activity
1 complaint

Violations and Penalties

Total Violations
5
Violation Types
3 serious, 2 other-than-serious
Initial Penalties
$1,500
Penalties on Record
$1,500
Site Address
1000 Thompson Run Road, Monroeville, PA 15146
Industry
327320 Ready-Mix Concrete Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
OSHA citation code: 19100023 C01
Serious11$450$450May 28, 2002--
010021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious11$450$450May 28, 2002--
010031910.303
OSHA citation code: 19100303 G02 I
Serious11$600$600May 13, 2002--
02001A1910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other11$0$0May 13, 2002--
02001B1910.1200
Hazard Communication
OSHA citation code: 19101200 E01
Other11$0$0May 28, 2002--
Jan 12, 2000Planned (H) · Partial scope, Health#123318164$03 viol.

Inspection #123318164

Dates

Opened
Jan 12, 2000
Closing Conference Date
Jan 12, 2000
Closed
Oct 26, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
8

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1000 Thompson Run Road, Monroeville, PA 15146
Industry
327320 Ready-Mix Concrete Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Other11$0$0Jan 31, 2000--
010021910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 D02
Other11$0$0Jan 31, 2000--
010031910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 G01
Other11$0$0Jan 31, 2000--
Inspections 1 to 4 of 4, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.146Permit-Required Confined Spaces3 citations · $0
1910.219Mechanical Power-Transmission Apparatus3 citations · $765
1910.3033 citations · $1,650

Industry comparison

Violations per inspection
This employer3.5
Industry average3.3
Penalties per inspection
This employer$874
Industry average$2,354

Nonmetallic Mineral Product Manufacturing, 16,980 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: ready-mix concrete manufacturing reported 2.5 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 11.0%; NAICS 32732 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Monroeville, PA

All employers in Monroeville →