Skip to content
SafetyRecord logoSafetyRecord
ENERQUIP, INC.
$6,113
penalties
29
viol.
6
insp.

ENERQUIP, INC.

611 NORTH ROAD, MEDFORD, WI 54451

Inspections
6
Jan 1987 to Jun 2010 · 5 safety, 1 health
Violations
29
across 6 inspections
Penalties on record
$6,113
latest amounts in DOL records
By classification
Serious 13Willful 0Repeat 2Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 24, 2010Planned (H) · Partial scope, Safety#313178139$3,7505 viol.

Inspection #313178139

Dates

Opened
Jun 24, 2010
Closing Conference Date
Jun 24, 2010
Closed
Dec 27, 2010

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
5
Violation Types
5 serious
Initial Penalties
$6,250
Penalties on Record
$3,750
Site Address
611 North Road, Medford, WI 54451
Industry
332410 Power Boiler and Heat Exchanger Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
Ladders
OSHA citation code: 19100023 C01
Serious13$1,000$600Oct 21, 2010--
01001B1910.24
Step Bolts and Manhole Steps
OSHA citation code: 19100024 H
Serious13$0$0Oct 21, 2010--
010021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C06 I
Serious13$1,000$600Oct 21, 2010--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious13$1,750$1,050Oct 21, 2010--
010041910.333
Electrical - Selection and Use of Work Practices
OSHA citation code: 19100333 C02
Serious12$2,500$1,500Oct 21, 2010--
Dec 16, 2004Planned (H) · Partial scope, Safety#307038927$8582 viol.

Inspection #307038927

Dates

Opened
Dec 16, 2004
Closing Conference Date
Dec 16, 2004
Closed
Mar 25, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
27

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,225
Penalties on Record
$858
Site Address
611 North Road, Medford, WI 54451
Industry
332410 Power Boiler and Heat Exchanger Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Serious11$525$368Feb 10, 2005--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious31$700$490Feb 10, 2005--
Nov 5, 1991Planned (H) · Complete scope, Health#102475274$6255 viol.

Inspection #102475274

Dates

Opened
Nov 5, 1991
Closing Conference Date
Nov 6, 1991
Closed
Mar 26, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
22

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 3 other-than-serious
Initial Penalties
$625
Penalties on Record
$625
Site Address
611 North Road, Medford, WI 54451
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A5A0001
General Duty Clause, Section 5(a)(1)
Serious11$625$625Jan 27, 1992--
01001B1910.252
Welding, Cutting, and Brazing - General Requirements
OSHA citation code: 19100252 B04 IV
Serious11$0$0Jan 6, 1992--
020011904.2
Partial Exemption for Establishments in Certain Industries
OSHA citation code: 19040002 A
Other210$0$0Jan 6, 1992--
020021910.147
Control of Hazardous Energy (Lockout/Tagout)
OSHA citation code: 19100147 C01
Other11$0$0Jan 27, 1992--
020031910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other110$0$0Jan 27, 1992--
Dec 27, 1989Follow-Up (F) · Partial scope, Safety#103140497$01 viol.

Inspection #103140497

Dates

Opened
Dec 27, 1989
Closing Conference Date
Dec 27, 1989
Closed
Jan 17, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
37

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
611 North Road, Medford, WI 54451
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F04
Other11$0$0Feb 9, 1990--
Nov 2, 1989Planned (H) · Complete scope, Safety#102616760$7105 viol.

Inspection #102616760

Dates

Opened
Nov 2, 1989
Closing Conference Date
Nov 2, 1989
Closed
Jan 17, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
37

Violations and Penalties

Total Violations
5
Violation Types
2 serious, 2 repeat, 1 other-than-serious
Initial Penalties
$1,440
Penalties on Record
$710
Site Address
611 North Road, Medford, WI 54451
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 5 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 A02
Serious11$240$160Dec 22, 1989--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 V
Serious13$560$280Dec 22, 1989--
020011910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Repeat31$160$120Dec 22, 1989--
020021910.1200
Hazard Communication
OSHA citation code: 19101200 H01
Repeat32$480$150Dec 22, 1989--
030011904.5
Determination of Work-Relatedness
OSHA citation code: 19040005 D01
Other21$0$0Nov 24, 1989--
Jan 28, 1987Planned (H) · Complete scope, Safety#101662823$17011 viol.

Inspection #101662823

Dates

Opened
Jan 28, 1987
Closing Conference Date
Jan 28, 1987
Closed
May 1, 1987

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
23

Violations and Penalties

Total Violations
11
Violation Types
2 serious, 9 other-than-serious
Initial Penalties
$170
Penalties on Record
$170
Site Address
611 North Road, Medford, WI 54451
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 11 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious12$50$50Feb 20, 1987--
010021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A03 II
Serious12$120$120Feb 20, 1987--
020011910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 C04 I
Other12$0$0Mar 9, 1987--
020021910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other12$0$0Mar 9, 1987--
020031910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Other12$0$0Feb 20, 1987--
020041910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Other22$0$0Mar 9, 1987--
020051910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 M01
Other24$0$0Mar 9, 1987--
020061910.244
Other Portable Tools and Equipment
OSHA citation code: 19100244 B
Other11$0$0Feb 13, 1987--

Showing the 8 violations listed first by citation identifier. This inspection has 11 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1200Hazard Communication6 citations · $270
1910.212General Requirements for All Machines (Machine Guarding)4 citations · $1,710
1910.219Mechanical Power-Transmission Apparatus4 citations · $0

Industry comparison

BLS 2024 survey: power boiler and heat exchanger manufacturing reported 3.2 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 16.5%; NAICS 33241 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in MEDFORD, WI