Skip to content
SafetyRecord logoSafetyRecord
ESSEX NORTHEAST SERVICE CENTER COMPANY
$7,450
penalties
22
viol.
5
insp.

ESSEX NORTHEAST SERVICE CENTER COMPANY

1000 CONROY PL., Easton, PA 18040NAICS 332321 Metal Window and Door Manufacturing

Inspections
5
Jan 2003 to Dec 2008 · 3 safety, 2 health
Violations
22
across 5 inspections
Penalties on record
$7,450
latest amounts in DOL records
By classification
Serious 19Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Dec 17, 2008Referral (C) · Partial scope, Safety#311275010$1,4733 viol.

Inspection #311275010

Dates

Opened
Dec 17, 2008
Closing Conference Date
Mar 13, 2009
Closed
Apr 9, 2009

Inspection

Advance Notice
Yes
Owner Type
Private
Union Status
Yes
Number of Employees
70
Related Activity
1 referral

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$1,473
Penalties on Record
$1,473
Site Address
1000 Conroy Pl., Easton, PA 18040
Industry
332321 Metal Window and Door Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling4 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Benzene1712P / 5A0ppm
Gravimetric DeterminationQC21P / 1A0.3114 - 0.3557mg/m³
Methyl (n-amyl) ketone1712P / 5A0 - 3.757558ppm
Sample WeightQC21P / 1A0.045 - 0.052mg
Silica, Crystalline Quartz (Respirable Fraction)21P / 1A0%
Xylene1712P / 5A0 - 1.808297ppm

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious12$900$900Mar 24, 2009--
01002A1910.1200
Hazard Communication
OSHA citation code: 19101200 G01
Serious22$573$573Mar 19, 2009--
01002B1910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious22$0$0Mar 19, 2009--
Nov 19, 2008Planned (H) · Complete scope, Safety#311272363$1,5763 viol.

Inspection #311272363

Dates

Opened
Nov 19, 2008
Closing Conference Date
Jan 8, 2009
Closed
Feb 10, 2009

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
70

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$2,250
Penalties on Record
$1,576
Site Address
1000 Conroy Pl., Easton, PA 18040
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.106
OSHA citation code: 19100106 E02 II
Serious13$1,125$788Feb 3, 2009--
01001B1910.106
OSHA citation code: 19100106 E02 IIB2
Serious13$0$0Feb 3, 2009--
010021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01 II
Serious11$1,125$788Feb 3, 2009--
Jan 20, 2006Referral (C) · Complete scope, Health#308176510$1,7508 viol.

Inspection #308176510

Dates

Opened
Jan 20, 2006
Closing Conference Date
Mar 8, 2006
Closed
May 24, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
42
Related Activity
1 referral

Violations and Penalties

Total Violations
8
Violation Types
6 serious, 2 other-than-serious
Initial Penalties
$3,500
Penalties on Record
$1,750
Site Address
1000 Conroy Pl., Easton, PA 18040
Industry
332321 Metal Window and Door Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Chemical Exposure Sampling18 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)40mg/m³
Benzene20ppm
Beryllium and Beryllium Compounds (as Be)40mg/m³
Cadmium40mg/m³
Chromium, Metal and Insoluble Salts40mg/m³
Cobalt, Metal, Dust and Fume (as Co)40mg/m³
Copper Fume (as Cu)40.0071573 - 0.0522434mg/m³
Gravimetric DeterminationQC20.3758 - 0.6212mg/m³
Iron Oxide Fume42.3972924 - 11.2871857mg/m³
Lead, Inorganic (as Pb)40mg/m³
Manganese Fume (as Mn)40.0809089 - 0.8671883mg/m³
Methyl (n-amyl) ketone21.368309 - 2.005471ppm
Molybdenum (as Mo), Insoluble Compounds (Total Dust)40mg/m³
Nickel, Metal and Insoluble compounds (as Ni)40mg/m³
Particulates not otherwise regulated (Respirable Fraction)10.3758mg/m³
Sample WeightQC20.306 - 0.581mg
Silica, Crystalline Quartz (Respirable Fraction)12.9%
Vanadium fume (as V2O5)40mg/m³
Xylene20.8845 - 0.9374ppm
Zinc Oxide Fume40.1487874 - 15.499794mg/m³

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 D01
Serious212$1,500$750Mar 23, 2006--
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 K01
Serious212$0$0Apr 24, 2006--
020011910.134
Respiratory Protection
OSHA citation code: 19100134 C02 I
Other12$0$0Mar 29, 2006--
020021910.95
Occupational Noise Exposure
OSHA citation code: 19100095 L01
Other212$0$0Mar 29, 2006--
03001A1910.1000
Air Contaminants
OSHA citation code: 19101000 A02
Serious12$2,000$1,000Jul 7, 2006--
03001B1910.1000
Air Contaminants
OSHA citation code: 19101000 E
Serious12$0$0Aug 15, 2006--
03001C1910.134
Respiratory Protection
OSHA citation code: 19100134 A01
Serious12$0$0Apr 24, 2006--
03001D1910.134
Respiratory Protection
OSHA citation code: 19100134 C01
Serious12$0$0May 9, 2006--
Nov 3, 2005Planned (H) · Complete scope, Safety#308175108$2,6518 viol.

Inspection #308175108

Dates

Opened
Nov 3, 2005
Closing Conference Date
Nov 21, 2005
Closed
Feb 3, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
65

Violations and Penalties

Total Violations
8
Violation Types
7 serious, 1 other-than-serious
Initial Penalties
$5,300
Penalties on Record
$2,651
Site Address
1000 Conroy Pl., Easton, PA 18040
Industry
332321 Metal Window and Door Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A5A0001
General Duty Clause, Section 5(a)(1)
Serious12$2,500$1,250Mar 17, 2006--
01001B1910.22
OSHA citation code: 19100022 A01
Serious12$0$0Jan 26, 2006--
010021910.252
General requirements
OSHA citation code: 19100252 B02 III
Serious19$1,225$613Jan 19, 2006--
01003A1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 E03
Serious12$875$438Jan 19, 2006--
01003B1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Serious12$0$0Jan 19, 2006--
01003C1910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B03
Serious12$0$0Jan 19, 2006--
010041910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious12$700$350Jan 23, 2006--
020011910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 II
Other13$0$0Jan 23, 2006--
Jan 22, 2003Complaint (B) · Partial scope, Health#305017766$00 viol.

Inspection #305017766

Dates

Opened
Jan 22, 2003
Closing Conference Date
Jan 31, 2003
Closed
Feb 11, 2003

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
42
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1000 Conroy Pl., Easton, PA 18040
Industry
332321 Metal Window and Door Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials4 citations · $1,338
1910.1200Hazard Communication3 citations · $923
1910.134Respiratory Protection3 citations · $0

Chemical exposure sampling

Samples
121
Substances
20
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer4.4
Industry average3.3
Penalties per inspection
This employer$1,490
Industry average$2,301

Fabricated Metal Product Manufacturing, 45,936 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: metal window and door manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.3%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in Easton, PA

All employers in Easton →