Skip to content
SafetyRecord logoSafetyRecord
FIRE DEPT NEW HOPE
$0
penalties
6
viol.
1
insp.

FIRE DEPT NEW HOPE

NEW HOPE RD, NEW HOPE, NY 13118

Inspections
1
Nov 1985 to Nov 1985 · 1 safety, 0 health
Violations
6
across 1 inspection
Penalties on record
$0
latest amounts in DOL records
By classification
Serious 2Willful 0Repeat 0Other 4

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 25, 1985Planned (H) · Complete scope, Safety#102204039$06 viol.

Inspection #102204039

Dates

Opened
Nov 25, 1985
Closing Conference Date
Nov 25, 1985
Closed
Dec 31, 1999

Inspection

Advance Notice
No
Owner Type
Local government
Union Status
No
Number of Employees
130

Violations and Penalties

Total Violations
6
Violation Types
2 serious, 4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
New Hope Rd, New Hope, NY 13118
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (6 of 6 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.23
Ladders
OSHA citation code: 19100023 D01 III
Serious28$0$0Jan 17, 1986--
010021910.304
Electrical - Wiring Design and Protection
OSHA citation code: 19100304 F05 VC1
Serious140$0$0Dec 27, 1985--
020011910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other750$0$0Dec 27, 1985--
020021910.37
Maintenance, Safeguards, and Operational Features for Exit Routes
OSHA citation code: 19100037 Q01
Other750$0$0Dec 27, 1985--
020031910.303
Electrical - General Requirements
OSHA citation code: 19100303 B01
Other150$0$0Dec 27, 1985--
020041910.303
Electrical - General Requirements
OSHA citation code: 19100303 G01 IIIA
Other318$0$0Jan 17, 1986--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.37Maintenance, Safeguards, and Operational Features for Exit Routes2 citations · $0
1910.303Electrical - General Requirements2 citations · $0
1910.23Ladders1 citation · $0

Other inspected employers in NEW HOPE, NY