Skip to content
SafetyRecord logoSafetyRecord
FLEX STEEL INDUSTRIES
$2,700
penalties
19
viol.
2
insp.

FLEX STEEL INDUSTRIES

72104 COUNTY ROAD 23, NEW PARIS, IN 46553

Inspections
2
Jun 1985 to Feb 1994 · 1 safety, 1 health
Violations
19
across 2 inspections
Penalties on record
$2,700
latest amounts in DOL records
By classification
Serious 5Willful 0Repeat 0Other 14

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 21, 1994Complaint (B) · Partial scope, Health#124065004$2,5009 viol.

Inspection #124065004

Dates

Opened
Feb 21, 1994
Closing Conference Date
Mar 2, 1994
Closed
Sep 13, 1994

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
215
Related Activity
1 complaint

Violations and Penalties

Total Violations
9
Violation Types
2 serious, 7 other-than-serious
Initial Penalties
$5,000
Penalties on Record
$2,500
Site Address
72104 County Road 23, New Paris, IN 46553
Industry
Not classified in OSHA's inspection record.

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.146
Permit-Required Confined Spaces
OSHA citation code: 19100146 C01
Serious12$1,500$750Jul 11, 1994--
010021910.1200
Hazard Communication
OSHA citation code: 19101200 H
Serious1215$3,500$1,750Jul 11, 1994--
02001400.402Other9215$0$0Jul 11, 1994--
020021910.22
OSHA citation code: 19100022 A01
Other36$0$0Jun 13, 1994--
020031910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B05 I
Other14$0$0Sep 12, 1994--
020041910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 B09
Other14$0$0Jul 11, 1994--
020051910.107
Spray Finishing Using Flammable and Combustible Materials
OSHA citation code: 19100107 G02
Other14$0$0Jul 11, 1994--
02010A1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 I
Other12$0$0Jul 11, 1994--
02010B1910.1200
Hazard Communication
OSHA citation code: 19101200 F05 II
Other12$0$0Jul 11, 1994--
Jun 17, 1985Planned (H) · Complete scope, Safety#2729176$20010 viol.

Inspection #2729176

Dates

Opened
Jun 17, 1985
Closing Conference Date
Jun 19, 1985
Closed
Dec 31, 1985

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
170

Violations and Penalties

Total Violations
10
Violation Types
3 serious, 7 other-than-serious
Initial Penalties
$0
Penalties on Record
$200
Site Address
72104 County Road 23, New Paris, IN 46553
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A1
Serious44$0$200Nov 30, 1985--
01001B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C1 I
Serious33$0$0Oct 14, 1985--
01001C1910.217
Mechanical Power Presses
OSHA citation code: 19100217 C2 I A
Serious11$0$0Oct 14, 1985--
020011910.37
OSHA citation code: 19100037 Q01
Other21$0$0Jul 12, 1985--
020021910.37
OSHA citation code: 19100037 Q02
Other110$0$0Jul 12, 1985--
020031910.106
OSHA citation code: 19100106 G08
Other11$0$0Jul 12, 1985--
020041910.303
OSHA citation code: 19100303 F
Other11$0$0Jul 22, 1985--
020051910.308
Special systems
OSHA citation code: 19100308 B03
Other327$0$0Aug 31, 1985--
020061910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other11$0$0Jul 12, 1985--
020071910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E02 I
Other11$0$0Jul 12, 1985--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.107Spray Finishing Using Flammable and Combustible Materials3 citations · $0
1910.1200Hazard Communication3 citations · $1,750
1910.219Mechanical Power-Transmission Apparatus2 citations · $0

Other inspected employers in NEW PARIS, IN

All employers in NEW PARIS →