Skip to content
SafetyRecord logoSafetyRecord
FLORIDA PLASTERING INC
$3,010
penalties
19
viol.
10
insp.

FLORIDA PLASTERING INC

MIAMI DADE COMMUNITY COLLEGE, Miami, FL 33176

Inspections
10
Mar 1977 to Jun 1990 · 10 safety, 0 health
Violations
19
across 10 inspections
Penalties on record
$3,010
latest amounts in DOL records
By classification
Serious 6Willful 0Repeat 5Other 8

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 26, 1990Planned (H) · Complete scope, Safety#110054855$01 viol.

Inspection #110054855

Dates

Opened
Jun 26, 1990
Closing Conference Date
Jun 27, 1990
Closed
Aug 24, 1990

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
7

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1060 N American Way, Miami, FL 33025
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A13
Other12$0$0Jul 29, 1990--
Nov 12, 1987Unprogrammed Related (G) · Complete scope, Safety#101206753$6503 viol.

Inspection #101206753

Dates

Opened
Nov 12, 1987
Closing Conference Date
Nov 13, 1987
Closed
Mar 14, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
16
Related Activity
1 complaint

Violations and Penalties

Total Violations
3
Violation Types
2 serious, 1 other-than-serious
Initial Penalties
$1,260
Penalties on Record
$650
Site Address
7595-7515 Sw 152nd Ave., Miami, FL 33193
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious13$450$250Jan 21, 1988--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Serious66$810$400Jan 21, 1988--
020011926.25
Housekeeping
OSHA citation code: 19260025 A
Other13$0$0Jan 21, 1988--
Nov 21, 1985Unprogrammed Related (G) · Complete scope, Safety#100351741$1,4407 viol.

Inspection #100351741

Dates

Opened
Nov 21, 1985
Closing Conference Date
Nov 25, 1985
Contested
Jan 14, 1986
Closed
Aug 29, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
5
Related Activity
1 complaint

Violations and Penalties

Total Violations
7
Violation Types
4 serious, 1 repeat, 2 other-than-serious
Initial Penalties
$6,240
Penalties on Record
$1,440
Site Address
11800 Sw 147th Ave., Miami, FL 33196
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (5 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G01
Serious12$640$320Dec 23, 1985Jan 14, 1986-
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G03
Serious12$0$0Dec 19, 1985Jan 14, 1986-
01001C1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 G05
Serious12$0$0Dec 23, 1985Jan 14, 1986-
01001D1926.500
Fall Protection - Scope, Application, and Definitions
OSHA citation code: 19260500 F01 IV
Serious12$0$0Dec 23, 1985Jan 14, 1986-
020011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Repeat14$5,600$1,120Dec 23, 1985Jan 14, 1986-

Showing the 5 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jan 19, 1984Planned (H) · Complete scope, Safety#223545$01 viol.

Inspection #223545

Dates

Opened
Jan 19, 1984
Closing Conference Date
Jan 20, 1984
Closed
Apr 3, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
High Vehicle Park, Miami, FL 33159
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.401
OSHA citation code: 19260401 F
Other1-$0$0Mar 11, 1984--
Nov 29, 1983Planned (H) · Complete scope, Safety#13426325$6001 viol.

Inspection #13426325

Dates

Opened
Nov 29, 1983
Closing Conference Date
Nov 30, 1983
Closed
Feb 5, 1986

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
2

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$600
Penalties on Record
$600
Site Address
195 N E 2nd Ave, Miami, FL 33179
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Repeat1-$600$600Dec 27, 1983--
Nov 17, 1981Planned (H) · Complete scope, Safety#13382544$02 viol.

Inspection #13382544

Dates

Opened
Nov 17, 1981
Closing Conference Date
Nov 20, 1981
Closed
Jan 28, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
14

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1603 Nw 107th Ave, Miami, FL 33172
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D03
Other7-$0$0Dec 5, 1981--
01001B1926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Other7-$0$0Dec 5, 1981--
Jun 27, 1977Follow-Up (F) · Complete scope, Safety#13409107$00 viol.

Inspection #13409107

Dates

Opened
Jun 27, 1977
Closing Conference Date
Jun 27, 1977
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Miami Dade Community College, Miami, FL 33176
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jun 13, 1977Follow-Up (F) · Complete scope, Safety#13322003$1601 viol.

Inspection #13322003

Dates

Opened
Jun 13, 1977
Closing Conference Date
Jun 13, 1977
Closed
May 29, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
1
Violation Types
1 repeat
Initial Penalties
$160
Penalties on Record
$160
Site Address
Miami Dade Community College-S, Miami, FL 33176
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Repeat1-$160$160Jun 26, 1977--
May 26, 1977Planned (H) · Complete scope, Safety#13409024$1602 viol.

Inspection #13409024

Dates

Opened
May 26, 1977
Closing Conference Date
May 26, 1977
Closed
Jul 23, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
3

Violations and Penalties

Total Violations
2
Violation Types
2 repeat
Initial Penalties
$160
Penalties on Record
$160
Site Address
Miami Dade Junior College Sout, Miami, FL 33156
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A04
Repeat1-$80$80Jun 6, 1977--
010021926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 E04
Repeat1-$80$80Jun 6, 1977--
Mar 9, 1977Planned (H) · Partial scope, Safety#13354659$01 viol.

Inspection #13354659

Dates

Opened
Mar 9, 1977
Closing Conference Date
Mar 9, 1977
Closed
Mar 21, 1977

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
40

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1401 Nw 7th Ave, Miami, FL 33125
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.25
Housekeeping
OSHA citation code: 19260025 A
Other1-$0$0Mar 18, 1977--
Inspections 1 to 10 of 10, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.451Scaffolding - General Requirements12 citations · $2,760
1926.25Housekeeping2 citations · $0
1926.20General Safety and Health Provisions1 citation · $0

Other inspected employers in Miami, FL