Skip to content
SafetyRecord logoSafetyRecord
GALLATIN WOOD PRODUCTS
$315
penalties
15
viol.
2
insp.

GALLATIN WOOD PRODUCTS

I-75 AND U. S. 127, Warsaw, KY 41095

Inspections
2
Dec 1987 to Jun 1992 · 2 safety, 0 health
Violations
15
across 2 inspections
Penalties on record
$315
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 7

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jun 24, 1992Planned (H) · Complete scope, Safety#123818239$1208 viol.

Inspection #123818239

Dates

Opened
Jun 24, 1992
Closing Conference Date
Jun 24, 1992
Final Order
Nov 9, 1992
Closed
Dec 14, 1992

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
8
Violation Types
2 serious, 6 other-than-serious
Initial Penalties
$120
Penalties on Record
$120
Site Address
I-75 And U. S. 127, Warsaw, KY 41095
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$120$120Dec 14, 1992-Nov 9, 1992
01001B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Dec 14, 1992-Nov 9, 1992
020011910.303
OSHA citation code: 19100303 G01 II
Other11$0$0Dec 14, 1992-Nov 9, 1992
020021910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B01
Other12$0$0Dec 14, 1992-Nov 9, 1992
020031910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other12$0$0Dec 14, 1992-Nov 9, 1992
02004201800101Other18$0$0Dec 14, 1992-Nov 9, 1992
020051910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other11$0$0Dec 14, 1992-Nov 9, 1992
020061910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other11$0$0Dec 14, 1992-Nov 9, 1992
Dec 1, 1987Planned (H) · Complete scope, Safety#2798056$1957 viol.

Inspection #2798056

Dates

Opened
Dec 1, 1987
Closing Conference Date
Dec 1, 1987
Final Order
Jul 21, 1988
Closed
Jan 23, 1991

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
10

Violations and Penalties

Total Violations
7
Violation Types
6 serious, 1 other-than-serious
Initial Penalties
$390
Penalties on Record
$195
Site Address
I-75 And U. S. 127, Warsaw, KY 41095
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (7 of 7 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 G01
Serious11$150$75Jan 22, 1988-Jul 21, 1988
01002A1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H01
Serious22$150$75Jan 29, 1988-Jul 21, 1988
01002B1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H03
Serious22$0$0Jan 14, 1988-Jul 21, 1988
01002C1910.213
Woodworking Machinery Requirements
OSHA citation code: 19100213 H04
Serious22$0$0Dec 30, 1987-Jul 21, 1988
01003A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Serious11$90$45Jan 8, 1988-Jul 21, 1988
01003B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious11$0$0Jan 8, 1988-Jul 21, 1988
02001200600201Other110$0$0Dec 1, 1987-Jul 21, 1988
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.219Mechanical Power-Transmission Apparatus4 citations · $165
1910.213Woodworking Machinery Requirements4 citations · $150
1910.305Wiring methods, components, and equipment for general use2 citations · $0

Other inspected employers in Warsaw, KY

All employers in Warsaw →