Skip to content
SafetyRecord logoSafetyRecord
GLACIER VANDERVELL, INC.
$7,949
penalties
18
viol.
2
insp.

GLACIER VANDERVELL, INC.

5130 STATE ROURE 60, NW, McConnelsville, OH 43756NAICS 333613 Mechanical Power Transmission Equipment Manufacturing

Inspections
2
Jun 2004 to Aug 2006 · 0 safety, 2 health
Violations
18
across 2 inspections
Penalties on record
$7,949
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 7, 2006Planned (H) · Complete scope, Health#309184851$4,6759 viol.

Inspection #309184851

Dates

Opened
Aug 7, 2006
Closing Conference Date
Aug 10, 2006
Closed
Oct 27, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
33

Violations and Penalties

Total Violations
9
Violation Types
8 serious, 1 other-than-serious
Initial Penalties
$2,975
Penalties on Record
$4,675
Site Address
5130 State Roure 60, Nw, McConnelsville, OH 43756
Industry
331423

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling1 substance sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Lead, Inorganic (as Pb)30 - 0.129mg/m³

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.27
OSHA citation code: 19100027 B01 II
Serious13$1,700$1,480Oct 16, 2006--
01001B1910.27
OSHA citation code: 19100027 B04
Serious13$0$0Sep 18, 2006--
01001C1910.27
OSHA citation code: 19100027 D01 IV
Serious13$0$0Oct 16, 2006--
01002A1910.147
The control of hazardous energy (lockout/tagout)
OSHA citation code: 19100147 E01
Serious13$1,275$1,070Sep 18, 2006--
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 F03
Serious13$0$0Sep 18, 2006--
01006A1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Serious112$0$2,125Sep 18, 2006--
01006B1910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 J03 I
Serious14$0$0Sep 18, 2006--
01006C1910.335
Electrical - Safeguards
OSHA citation code: 19100335 A01 I
Serious16$0$0Oct 16, 2006--
020011910.24
OSHA citation code: 19100024 H
Other212$0$0Sep 18, 2006--
Jun 28, 2004Planned (H) · Partial scope, Health#307882274$3,2749 viol.

Inspection #307882274

Dates

Opened
Jun 28, 2004
Closing Conference Date
Jul 1, 2004
Closed
Aug 17, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
35

Violations and Penalties

Total Violations
9
Violation Types
9 other-than-serious
Initial Penalties
$4,675
Penalties on Record
$3,274
Site Address
5130 State Roure 60, Nw, McConnelsville, OH 43756
Industry
333613 Mechanical Power Transmission Equipment Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Chemical Exposure Sampling13 substances sampled

Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.

SubstanceSamplesResult RangeUnit
Antimony and Compounds (as Sb)50mg/m³
Beryllium and Beryllium Compounds (as Be)50mg/m³
Cadmium50mg/m³
Chromium, Metal and Insoluble Salts50mg/m³
Cobalt, Metal, Dust and Fume (as Co)50mg/m³
Copper Fume (as Cu)50 - 0.0151421mg/m³
Iron Oxide Fume50 - 0.3180232mg/m³
Lead, Inorganic (as Pb)50 - 0.0918734mg/m³
Manganese Fume (as Mn)50 - 0.0162343mg/m³
Molybdenum (as Mo), Insoluble Compounds (Total Dust)50mg/m³
Nickel, Metal and Insoluble compounds (as Ni)50mg/m³
Vanadium fume (as V2O5)50mg/m³
Zinc Oxide Fume50mg/m³

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.1025
Lead
OSHA citation code: 19101025 E03 IIB
Other11$2,125$1,488Aug 10, 2004--
01001B1910.1025
Lead
OSHA citation code: 19101025 E03 IV
Other11$0$0Aug 10, 2004--
01001C1910.1025
Lead
OSHA citation code: 19101025 E03 III
Other11$0$0Aug 10, 2004--
01001D1910.1025
Lead
OSHA citation code: 19101025 E04 I
Other11$0$0Aug 10, 2004--
01002A1910.1025
Lead
OSHA citation code: 19101025 G02 VII
Other11$1,275$893Aug 10, 2004--
01002B1910.1025
Lead
OSHA citation code: 19101025 M02 I
Other11$0$0Aug 10, 2004--
01003A1910.1025
Lead
OSHA citation code: 19101025 N01 I
Other11$1,275$893Aug 10, 2004--
01003B1910.1025
Lead
OSHA citation code: 19101025 N02 IIA
Other11$0$0Aug 10, 2004--
01003C1910.1025
Lead
OSHA citation code: 19101025 N03 IIC
Other11$0$0Aug 10, 2004--
Inspections 1 to 2 of 2, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead9 citations · $3,274
1910.273 citations · $1,480
1910.305Wiring methods, components, and equipment for general use2 citations · $2,125

Chemical exposure sampling

Samples
68
Substances
13
Inspections
2

Sample results are listed in the record of each inspection that collected them.

Industry comparison

Violations per inspection
This employer9.0
Industry average3.4
Penalties per inspection
This employer$3,975
Industry average$2,141

Machinery Manufacturing, 17,994 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in McConnelsville, OH