GUARANTEED FINISHING UNLIMITED, INC.
3200 WEST 121ST STREET, Cleveland, OH 44111 · NAICS 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 14, 2010#314067059Jan 14, 2010FatalityAccident (A) · Partial scope, SafetyFatality#314067059$7,2005 viol.5 violations$7,200 in penalties
Inspection #314067059
Dates
- Opened
- Jan 14, 2010
- Closing Conference Date
- Jan 14, 2010
- Closed
- Jan 18, 2011
Inspection
- Advance Notice
- Yes
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 27
- Related Activity
- 1 accident
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 4 serious, 1 other-than-serious
- Initial Penalties
- $11,100
- Penalties on Record
- $7,200
- Site Address
- 3200 West 121st Street, Cleveland, OH 44111
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Accident Inspection: This inspection record is categorized as an accident inspection in the U.S. Department of Labor OSHA enforcement data. Employers must report work-related fatalities within 8 hours, and work-related inpatient hospitalizations, amputations, or losses of an eye within 24 hours. An accident-related inspection does not by itself determine fault.
Incident Investigation Summaries
Incident investigation summaries linked to this inspection through OSHA's accident and injury enforcement data. These summaries describe the reported incident. The enforcement outcome for the linked inspection is in the inspection details above.
Employee is killed when struck by automated hoisting machine
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.23 OSHA citation code: 19100023 C03 | Serious | 1 | 2 | $3,000 | $2,200 | Mar 16, 2010 | - | - |
| 01002 | 1910.124 OSHA citation code: 19100124 J03 | Serious | 2 | 6 | $1,500 | $1,000 | Mar 16, 2010 | - | - |
| 01003 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C06 I | Serious | 1 | 4 | $1,500 | $1,000 | Mar 16, 2010 | - | - |
| 01004 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 G01 | Other | 1 | 2 | $900 | $0 | Mar 31, 2010 | - | - |
| 01005 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 2 | $4,200 | $3,000 | Mar 16, 2010 | - | - |
Aug 28, 2008#312545023Aug 28, 2008Complaint (B) · Partial scope, Health#312545023$1,9506 viol.6 violations$1,950 in penalties
Inspection #312545023
Dates
- Opened
- Aug 28, 2008
- Closing Conference Date
- Sep 30, 2008
- Contested
- Oct 30, 2008
- Final Order
- Mar 12, 2009
- Closed
- Apr 23, 2009
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 40
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 6
- Violation Types
- 4 serious, 2 other-than-serious
- Initial Penalties
- $3,250
- Penalties on Record
- $1,950
- Site Address
- 3200 W. 121th St., Cleveland, OH 44111
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling3 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Chromic Acid and Chromates (as CrO3) | 3 | 0 | mg/m³ |
| Chromium (VI) - TWA | 3 | 0 | mg/m³ |
| Hydrogen Chloride | 12 | 0 - 0.141477 | ppm |
Violations
Violation list (6 of 6 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001A | 1910.124 OSHA citation code: 19100124 G02 | Serious | 1 | 2 | $1,000 | $600 | Oct 15, 2008 | Oct 30, 2008 | Mar 12, 2009 |
| 01002 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B02 | Serious | 1 | 3 | $1,250 | $750 | Oct 17, 2008 | Oct 30, 2008 | Mar 12, 2009 |
| 01003A | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 I | Serious | 2 | 10 | $1,000 | $600 | Nov 9, 2008 | Oct 30, 2008 | Mar 12, 2009 |
| 01003B | 1910.1200 Hazard Communication OSHA citation code: 19101200 F05 II | Serious | 2 | 10 | $0 | $0 | Nov 9, 2008 | Oct 30, 2008 | Mar 12, 2009 |
| 02001 | 1910.147 The control of hazardous energy (lockout/tagout) OSHA citation code: 19100147 C04 I | Other | 1 | 3 | $0 | $0 | Nov 9, 2008 | Oct 30, 2008 | Mar 12, 2009 |
| 02002 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E03 | Other | 1 | 10 | $0 | $0 | Oct 25, 2008 | Oct 30, 2008 | Mar 12, 2009 |
Dec 29, 1999#302511100Dec 29, 1999Complaint (B) · Partial scope, Health#302511100$2,2069 viol.9 violations$2,206 in penalties
Inspection #302511100
Dates
- Opened
- Dec 29, 1999
- Closing Conference Date
- Feb 1, 2000
- Closed
- Mar 23, 2000
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 47
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 5 serious, 4 other-than-serious
- Initial Penalties
- $3,150
- Penalties on Record
- $2,206
- Site Address
- 3200 W. 121th St., Cleveland, OH 44111
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (9 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.37 OSHA citation code: 19100037 F01 | Serious | 1 | 1 | $700 | $490 | Apr 10, 2000 | - | - |
| 01002 | 1910.110 Storage and Handling of Liquefied Petroleum Gases OSHA citation code: 19100110 F02 I | Serious | 1 | 3 | $875 | $613 | Feb 10, 2000 | - | - |
| 01003 | 1910.124 OSHA citation code: 19100124 G02 | Serious | 1 | 3 | $875 | $613 | Feb 10, 2000 | - | - |
| 01004A | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B02 | Serious | 1 | 3 | $700 | $490 | Feb 10, 2000 | - | - |
| 01004B | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 G02 III | Serious | 2 | 3 | $0 | $0 | Feb 10, 2000 | - | - |
| 02001 | 1904.2 OSHA citation code: 19040002 A | Other | 2 | 47 | $0 | $0 | Feb 25, 2000 | - | - |
| 02002 | 1910.37 OSHA citation code: 19100037 Q02 | Other | 1 | 5 | $0 | $0 | Feb 10, 2000 | - | - |
| 02003 | 1910.37 OSHA citation code: 19100037 Q05 | Other | 1 | 20 | $0 | $0 | Feb 10, 2000 | - | - |
| 02004 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 A02 IIIG | Other | 1 | 1 | $0 | $0 | Feb 10, 2000 | - | - |
Apr 17, 1996#103011649Apr 17, 1996Complaint (B) · Partial scope, Safety#103011649$4203 viol.3 violations$420 in penalties
Inspection #103011649
Dates
- Opened
- Apr 17, 1996
- Closing Conference Date
- May 3, 1996
- Closed
- Jul 3, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 49
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 1 serious, 2 other-than-serious
- Initial Penalties
- $1,225
- Penalties on Record
- $420
- Site Address
- 3200 W. 121th St., Cleveland, OH 44111
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.94 Ventilation OSHA citation code: 19100094 D09 VIII | Other | 1 | 6 | $700 | $0 | Jun 17, 1996 | - | - |
| 01003 | 1910.178 Powered Industrial Trucks OSHA citation code: 19100178 P01 | Serious | 2 | 49 | $525 | $420 | May 23, 1996 | - | - |
| 02001 | 1910.305 Wiring methods, components, and equipment for general use OSHA citation code: 19100305 B01 | Other | 2 | 3 | $0 | $0 | Jun 1, 1996 | - | - |
Apr 17, 1996#103011631Apr 17, 1996Complaint (B) · Partial scope, Health#103011631$2,74512 viol.12 violations$2,745 in penalties
Inspection #103011631
Dates
- Opened
- Apr 17, 1996
- Closing Conference Date
- May 3, 1996
- Closed
- Oct 21, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- No
- Number of Employees
- 49
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 12
- Violation Types
- 10 serious, 2 other-than-serious
- Initial Penalties
- $7,350
- Penalties on Record
- $2,745
- Site Address
- 3200 W. 121th St., Cleveland, OH 44111
- Industry
- 332813 Electroplating, Plating, Polishing, Anodizing, and Coloring
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Chemical Exposure Sampling4 substances sampled
Air monitoring samples collected by OSHA during this inspection. Results grouped by substance.
| Substance | Samples | Result Range | Unit |
|---|---|---|---|
| Formaldehyde | 1 | 0.0757 | ppm |
| Hydrogen Chloride | 4 | 0 - 0.046 | ppm |
| Nitric Acid | 4 | 0 - 0.012 | ppm |
| Phosphoric Acid | 4 | 0 | ppm |
Violations
Violation list (10 of 12 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 B01 | Serious | 1 | 6 | $1,750 | $0 | Oct 1, 1996 | - | - |
| 01002A | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 G06 | Serious | 1 | 31 | $1,750 | $1,135 | Sep 1, 1996 | - | - |
| 01002B | 1910.95 Occupational Noise Exposure OSHA citation code: 19100095 I02 IIA | Serious | 1 | 12 | $0 | $0 | Jun 17, 1996 | - | - |
| 01003 | 1910.132 General requirements OSHA citation code: 19100132 A | Serious | 1 | 6 | $1,225 | $735 | May 25, 1996 | - | - |
| 01004 | 1910.1048 Formaldehyde OSHA citation code: 19101048 D01 I | Serious | 1 | - | $875 | $875 | Aug 17, 1996 | - | - |
| 01005 | 1910.1048 Formaldehyde OSHA citation code: 19101048 H01 I | Serious | 1 | - | $875 | $0 | May 21, 1996 | - | - |
| 01006A | 1910.1048 Formaldehyde OSHA citation code: 19101048 M01 II | Serious | 1 | - | $875 | $0 | Jun 1, 1996 | - | - |
| 01006B | 1910.1048 Formaldehyde OSHA citation code: 19101048 M04 I | Serious | 1 | - | $0 | $0 | May 20, 1996 | - | - |
| 01006C | 1910.1048 Formaldehyde OSHA citation code: 19101048 N01 | Serious | 1 | - | $0 | $0 | May 28, 1996 | - | - |
| 01006D | 1910.1200 Hazard Communication OSHA citation code: 19101200 H | Serious | 1 | 12 | $0 | $0 | May 21, 1996 | - | - |
Showing the 10 violations listed first by citation identifier. This inspection has 12 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Source: U.S. Department of Labor OSHA incident investigation data (`osha_accident` + `osha_accident_injury`). Linked via `rel_insp_nr` to the inspection activity number (exact government key). Injury, body part, source and event values are OSHA's own codes. OSHA states that these fields are not coded according to the requirements under the Occupational Injury and Illness Classification System (OIICS). Only the values present in the OSHA record are listed; an incident with no value that resolves in OSHA's code table shows "Injury details not recorded". Where a record covers several people, each field lists every value recorded across them.
Source: OSHA chemical exposure sampling data (OSHA Information System). P = Personal (worker breathing zone), A = Area (general air). Rows marked QC are analytical quality control measurements, not chemical exposures. OSHA PEL (Permissible Exposure Limit) values from the OSHA Occupational Chemical Database, matched via IMIS substance code (analyte code) (exact government key).
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1996 to 2010. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Standards cited
Chemical exposure sampling
Sample results are listed in the record of each inspection that collected them.
Industry comparison
Fabricated Metal Product Manufacturing, 45,931 employers with OSHA inspections. Arithmetic from DOL records.
BLS 2024 survey: electroplating, plating, polishing, anodizing, and coloring reported 4.1 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 12.2%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source