Skip to content
SafetyRecord logoSafetyRecord
HARDWARE & INDUSTRIAL TOOL CO
$2,130
penalties
28
viol.
5
insp.

HARDWARE & INDUSTRIAL TOOL CO

ROUTE 38 & CREEK ROAD, Hainesport, NJ 08036

Inspections
5
Jan 1979 to Feb 1982 · 4 safety, 1 health
Violations
28
across 5 inspections
Penalties on record
$2,130
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 19

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Feb 19, 1982Planned (H) · Complete scope, Safety#10998102$3009 viol.

Inspection #10998102

Dates

Opened
Feb 19, 1982
Closing Conference Date
Feb 23, 1982
Closed
Apr 20, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
46

Violations and Penalties

Total Violations
9
Violation Types
1 serious, 8 other-than-serious
Initial Penalties
$300
Penalties on Record
$300
Site Address
Route 38 And Creek Road, Hainesport, NJ 08036
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (9 of 9 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.217
Mechanical Power Presses
OSHA citation code: 19100217 C02 IA
Serious12-$300$300Mar 28, 1982--
020011910.23
OSHA citation code: 19100023 D01 II
Other1-$0$0Mar 5, 1982--
020021910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Other1-$0$0Mar 9, 1982--
020031910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Other1-$0$0Mar 5, 1982--
020041910.252
General requirements
OSHA citation code: 19100252 A02 IIB
Other1-$0$0Mar 1, 1982--
020051910.252
General requirements
OSHA citation code: 19100252 A02 IID
Other1-$0$0Mar 1, 1982--
020061910.252
General requirements
OSHA citation code: 19100252 A02 IVC
Other1-$0$0Mar 1, 1982--
020071910.304
Wiring design and protection
OSHA citation code: 19100304 F06 I
Other1-$0$0Mar 1, 1982--
020081910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 G02 II
Other1-$0$0Mar 1, 1982--
Nov 1, 1979Planned (H) · Partial scope, Health#10933976$1502 viol.

Inspection #10933976

Dates

Opened
Nov 1, 1979
Closing Conference Date
Nov 14, 1979
Contested
Dec 15, 1979
Final Order
Oct 15, 1981
Closed
Sep 14, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
27
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$490
Penalties on Record
$150
Site Address
Route 38 And Creek Road, Hainesport, NJ 08036
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B01
Serious4-$490$150Sep 1, 1982Dec 15, 1979Oct 15, 1981
01001B1910.95
Occupational Noise Exposure
OSHA citation code: 19100095 B03
Serious3-$0$0Dec 1, 1981Dec 15, 1979Oct 15, 1981
Jun 29, 1979Follow-Up (F) · Complete scope, Safety#10908549$00 viol.

Inspection #10908549

Dates

Opened
Jun 29, 1979
Closing Conference Date
Jun 29, 1979
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
27

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Route 38 & Creek Road, Hainesport, NJ 08036
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Feb 20, 1979Follow-Up (F) · Complete scope, Safety#10908390$00 viol.

Inspection #10908390

Dates

Opened
Feb 20, 1979
Closing Conference Date
Feb 20, 1979
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
32

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Route 38 & Creek Road, Hainesport, NJ 08036
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Jan 5, 1979Planned (H) · Complete scope, Safety#10908341$1,68017 viol.

Inspection #10908341

Dates

Opened
Jan 5, 1979
Closing Conference Date
Jan 16, 1979
Contested
Feb 15, 1979
Closed
Jun 29, 1979

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
36

Violations and Penalties

Total Violations
17
Violation Types
6 serious, 11 other-than-serious
Initial Penalties
$1,680
Penalties on Record
$1,680
Site Address
Route 38 & Creek Road, Hainesport, NJ 08036
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 17 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B03 I
Serious18-$420$420Jun 15, 1979Feb 15, 1979-
01001B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B06 II
Serious1-$0$0Jun 21, 1979Feb 15, 1979-
010021910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious16-$420$420Jun 21, 1979Feb 15, 1979-
010031910.217
Mechanical Power Presses
OSHA citation code: 19100217 C01 I
Serious20-$420$420Jun 21, 1979Feb 15, 1979-
01004A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Serious1-$240$240Feb 4, 1979Feb 15, 1979-
01004B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E03 I
Serious4-$0$0Feb 4, 1979Feb 15, 1979-
020011903.2
Posting of Notices; Availability of the Act, Regulations and Applicable Standards
OSHA citation code: 19030002 A01
Other1-$60$60Jan 28, 1979Feb 15, 1979-
02002A1904.2
OSHA citation code: 19040002 A
Other1-$60$60Jan 28, 1979Feb 15, 1979-
02002B1904.2
OSHA citation code: 19040002 A
Other1-$0$0Jan 28, 1979Feb 15, 1979-
020031904.5
OSHA citation code: 19040005 A
Other1-$60$60Jan 28, 1979Feb 15, 1979-

Showing the 10 violations listed first by citation identifier. This inspection has 17 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses6 citations · $1,560
1910.252General requirements3 citations · $0
1910.219Mechanical Power-Transmission Apparatus2 citations · $240

Other inspected employers in Hainesport, NJ

All employers in Hainesport →