HENRY COUNTY-PUBLIC WORKS
575 CEDAR STREET, PARIS, TN 38242
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Dec 7, 2010#315220798Dec 7, 2010Planned (H) · Complete scope, Safety#315220798$09 viol.9 violations$0 in penalties
Inspection #315220798
Dates
- Opened
- Dec 7, 2010
- Closing Conference Date
- Dec 7, 2010
- Closed
- Feb 23, 2011
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 150
Violations and Penalties
- Total Violations
- 9
- Violation Types
- 9 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- 237310 Highway, Street, and Bridge Construction
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 9 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E09 I | Serious | 1 | 2 | $0 | $0 | Feb 20, 2011 | - | - |
| 01002 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E09 III | Serious | 1 | 2 | $0 | $0 | Feb 20, 2011 | - | - |
| 01003 | 1910.176 Handling Materials - General OSHA citation code: 19100176 B | Serious | 1 | 2 | $0 | $0 | Feb 20, 2011 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Serious | 1 | 2 | $0 | $0 | Feb 20, 2011 | - | - |
| 01005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A04 | Serious | 1 | 2 | $0 | $0 | Feb 20, 2011 | - | - |
| 01006 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 B09 | Serious | 1 | 2 | $0 | $0 | Feb 20, 2011 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 9 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Mar 14, 2007#310709191Mar 14, 2007Planned (H) · Complete scope, Safety#310709191$01 viol.1 violation$0 in penalties
Inspection #310709191
Dates
- Opened
- Mar 14, 2007
- Closing Conference Date
- Mar 14, 2007
- Closed
- Mar 30, 2007
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 714
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- 811111 General Automotive Repair
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 A | Other | 1 | 10 | $0 | $0 | May 2, 2007 | - | - |
Sep 19, 2003#306779786Sep 19, 2003Planned (H) · Complete scope, Safety#306779786$04 viol.4 violations$0 in penalties
Inspection #306779786
Dates
- Opened
- Sep 19, 2003
- Closing Conference Date
- Sep 19, 2003
- Closed
- Nov 17, 2003
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 714
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 4 serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- 921190
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 90007 | Serious | 1 | 10 | $0 | $0 | Nov 15, 2003 | - | - |
| 01002 | 1910.141 Sanitation OSHA citation code: 19100141 D02 II | Serious | 1 | 10 | $0 | $0 | Nov 15, 2003 | - | - |
| 01003 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 E03 | Serious | 1 | 10 | $0 | $0 | Nov 15, 2003 | - | - |
| 01004 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 B02 | Serious | 1 | 10 | $0 | $0 | Nov 15, 2003 | - | - |
Jun 28, 1999#127333102Jun 28, 1999Planned (H) · Complete scope, Safety#127333102$04 viol.4 violations$0 in penalties
Inspection #127333102
Dates
- Opened
- Jun 28, 1999
- Closing Conference Date
- Jun 28, 1999
- Closed
- Aug 4, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 1,227
Violations and Penalties
- Total Violations
- 4
- Violation Types
- 3 serious, 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (4 of 4 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.242 Hand and Portable Powered Tools and Equipment, General OSHA citation code: 19100242 A | Serious | 1 | 1 | $0 | $0 | Jul 20, 1999 | - | - |
| 01002 | 1910.108 Dip Tanks (Reserved) OSHA citation code: 19100108 G06 I | Serious | 1 | - | $0 | $0 | Jul 20, 1999 | - | - |
| 01003 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E09 III | Serious | 1 | 1 | $0 | $0 | Jul 20, 1999 | - | - |
| 02001 | 1910.141 Sanitation OSHA citation code: 19100141 A03 I | Other | 1 | 1 | $0 | $0 | Jul 20, 1999 | - | - |
Mar 5, 1991#111075107Mar 5, 1991Planned (H) · No Inspection scope, Safety#111075107$00 viol.0 violations$0 in penalties
Inspection #111075107
Dates
- Opened
- Mar 5, 1991
- Closing Conference Date
- Mar 5, 1991
- Closed
- Mar 5, 1991
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 54
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Oct 18, 1990#111066510Oct 18, 1990Planned (H) · Complete scope, Safety#111066510$07 viol.7 violations$0 in penalties
Inspection #111066510
Dates
- Opened
- Oct 18, 1990
- Closing Conference Date
- Oct 18, 1990
- Closed
- Dec 5, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 941
Violations and Penalties
- Total Violations
- 7
- Violation Types
- 7 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (6 of 7 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.252 Welding, Cutting, and Brazing - General Requirements OSHA citation code: 19100252 A02 IVC | Other | 1 | 1 | $0 | $0 | Nov 1, 1990 | - | - |
| 01002 | 1910.304 Electrical - Wiring Design and Protection OSHA citation code: 19100304 F05 V | Other | 1 | 2 | $0 | $0 | Nov 1, 1990 | - | - |
| 01003 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Other | 2 | 4 | $0 | $0 | Nov 1, 1990 | - | - |
| 01004 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A05 | Other | 2 | 4 | $0 | $0 | Nov 1, 1990 | - | - |
| 01005 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Other | 1 | 2 | $0 | $0 | Nov 1, 1990 | - | - |
| 01006 | 1910.106 Flammable Liquids OSHA citation code: 19100106 G09 | Other | 1 | 54 | $0 | $0 | Nov 1, 1990 | - | - |
Showing the 6 violations listed first by citation identifier. This inspection has 7 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Jun 12, 1989#107899304Jun 12, 1989Follow-Up (F) · Partial scope, Safety#107899304$00 viol.0 violations$0 in penalties
Inspection #107899304
Dates
- Opened
- Jun 12, 1989
- Closing Conference Date
- Jun 12, 1989
- Closed
- Jun 12, 1989
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 955
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Apr 3, 1989#108213265Apr 3, 1989Planned (H) · Partial scope, Safety#108213265$03 viol.3 violations$0 in penalties
Inspection #108213265
Dates
- Opened
- Apr 3, 1989
- Closing Conference Date
- Apr 3, 1989
- Closed
- Jan 18, 1990
Inspection
- Advance Notice
- No
- Owner Type
- Local government
- Union Status
- No
- Number of Employees
- 955
Violations and Penalties
- Total Violations
- 3
- Violation Types
- 3 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 575 Cedar Street, Paris, TN 38242
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (3 of 3 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 900.501 | Other | 1 | 955 | $0 | $0 | Aug 1, 1989 | - | - |
| 01002 | 900.702 OSHA citation code: 9000702 E | Other | 1 | 955 | $0 | $0 | Aug 1, 1989 | - | - |
| 01003 | 500.502 OSHA citation code: 5000502 B00002 | Other | 1 | 955 | $0 | $0 | May 10, 1989 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
8 inspections, 1989 to 2010. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.