Skip to content
SafetyRecord logoSafetyRecord
HIGHLAND STEEL INC.
$1,590
penalties
10
viol.
5
insp.

HIGHLAND STEEL INC.

1037 DELAUM AVE, St. Mary's, PA 16857NAICS 332312 Fabricated Structural Metal Manufacturing

Inspections
5
Oct 1997 to Aug 2005 · 3 safety, 2 health
Violations
10
across 5 inspections
Penalties on record
$1,590
latest amounts in DOL records
By classification
Serious 9Willful 0Repeat 0Other 1

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Aug 17, 2005Planned (H) · No Inspection scope, Safety#306459181$00 viol.

Inspection #306459181

Dates

Opened
Aug 17, 2005
Closing Conference Date
Not recorded
Closed
Aug 17, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1037 Delaum Ave, St. Mary's, PA 16857
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Feb 6, 2001Complaint (B) · No Inspection scope, Health#303705156$00 viol.

Inspection #303705156

Dates

Opened
Feb 6, 2001
Closing Conference Date
Not recorded
Closed
Feb 8, 2001

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Not recorded
Number of Employees
Not recorded
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1037 Delaum Ave, St. Mary's, PA 16857
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Nov 23, 1999Complaint (B) · Partial scope, Safety#300282878$1,59010 viol.

Inspection #300282878

Dates

Opened
Nov 23, 1999
Closing Conference Date
Dec 6, 1999
Closed
May 31, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30
Related Activity
1 complaint

Violations and Penalties

Total Violations
10
Violation Types
9 serious, 1 other-than-serious
Initial Penalties
$2,450
Penalties on Record
$1,590
Site Address
1037 Delaum Ave, St. Mary's, PA 16857
Industry
332312 Fabricated Structural Metal Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (10 of 10 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
01001A1910.23
OSHA citation code: 19100023 C01
Serious21$875$600Dec 27, 1999--
01001B1910.252
General requirements
OSHA citation code: 19100252 B01 I
Serious13$0$0Dec 27, 1999--
01002A1910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 N01
Serious13$875$600Dec 27, 1999--
01002B1910.179
Overhead and Gantry Cranes
OSHA citation code: 19100179 L03 I
Serious13$0$0Dec 27, 1999--
01002C1910.184
Slings
OSHA citation code: 19100184 E01
Serious23$0$0Dec 27, 1999--
01003A1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious15$700$390Dec 27, 1999--
01003B1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 A04
Serious15$0$0Dec 27, 1999--
01003C1910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Serious25$0$0Dec 27, 1999--
01003D1910.243
Guarding of Portable Powered Tools
OSHA citation code: 19100243 C01
Serious12$0$0Dec 27, 1999--
020011910.242
Hand and Portable Powered Tools and Equipment, General
OSHA citation code: 19100242 B
Other16$0$0Dec 27, 1999--
Jan 28, 1999Planned (H) · No Inspection scope, Safety#300280351$00 viol.

Inspection #300280351

Dates

Opened
Jan 28, 1999
Closing Conference Date
Jan 28, 1999
Closed
Jan 28, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
30

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1037 Delaum Ave, St. Mary's, PA 16857
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Oct 8, 1997Planned (H) · Partial scope, Health#122167158$00 viol.

Inspection #122167158

Dates

Opened
Oct 8, 1997
Closing Conference Date
Oct 8, 1997
Closed
Oct 8, 1997

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
30

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
1037 Delaum Ave, St. Mary's, PA 16857
Industry
332312 Fabricated Structural Metal Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.215Abrasive Wheel Machinery3 citations · $390
1910.179Overhead and Gantry Cranes2 citations · $600
1910.184Slings1 citation · $0

Industry comparison

Violations per inspection
This employer2.0
Industry average3.3
Penalties per inspection
This employer$318
Industry average$2,302

Fabricated Metal Product Manufacturing, 45,919 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: fabricated structural metal manufacturing reported 3.4 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 7.9%). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in St. Mary's, PA

All employers in St. Mary's →