Skip to content
SafetyRecord logoSafetyRecord
HOWARD BROTHERS BUILDERS, INCORPORATED
$3,500
penalties
14
viol.
1
insp.

HOWARD BROTHERS BUILDERS, INCORPORATED

255 WARREN STREET, BROOKLINE, MA 02146

Inspections
1
Sep 1999 to Sep 1999 · 1 safety, 0 health
Violations
14
across 1 inspection
Penalties on record
$3,500
latest amounts in DOL records
By classification
Serious 11Willful 0Repeat 0Other 3

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Sep 17, 1999Unprogrammed Related (G) · Complete scope, Safety#302065446$3,50014 viol.

Inspection #302065446

Dates

Opened
Sep 17, 1999
Closing Conference Date
Sep 17, 1999
Closed
Dec 9, 1999

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7
Related Activity
1 referral

Violations and Penalties

Total Violations
14
Violation Types
11 serious, 3 other-than-serious
Initial Penalties
$6,750
Penalties on Record
$3,500
Site Address
255 Warren Street, Brookline, MA 02146
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (14 of 14 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.100
Head Protection (Construction)
OSHA citation code: 19260100 A
Serious19$450$225Nov 15, 1999--
010021926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Serious14$450$225Nov 15, 1999--
010031926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 E
Serious14$750$375Nov 15, 1999--
010041926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 B01 II
Serious16$750$375Nov 15, 1999--
010051926.404
Electrical - Wiring Design and Protection (Construction)
OSHA citation code: 19260404 F06
Serious16$750$375Nov 15, 1999--
010061926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIB
Serious36$450$225Nov 15, 1999--
010071926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 III
Serious27$750$375Nov 15, 1999--
010081926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 J01 IIID
Serious25$450$225Nov 15, 1999--
010091926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 E01
Serious16$450$225Nov 12, 1999--
010101926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B01
Serious38$1,050$650Nov 15, 1999--
010111926.502
Fall Protection Systems Criteria and Practices
OSHA citation code: 19260502 J01
Serious38$450$225Nov 15, 1999--
020011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIE
Other106$0$0Nov 15, 1999--
020021926.1052
Stairways (Construction)
OSHA citation code: 19261052 C04
Other46$0$0Nov 15, 1999--
020031926.1053
Ladders (Construction)
OSHA citation code: 19261053 B04
Other16$0$0Nov 15, 1999--
Inspections 1 to 1 of 1, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)4 citations · $825
1926.403Electrical - General Requirements (Construction)2 citations · $600
1926.404Electrical - Wiring Design and Protection (Construction)2 citations · $750

Other inspected employers in BROOKLINE, MA

All employers in BROOKLINE →