INDRA CO
1275 BUDD ST, Cincinnati, OH 45203
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 8, 1975#214680621Jan 8, 1975Follow-Up (F) · Complete scope, Safety#214680621$00 viol.0 violations$0 in penalties
Inspection #214680621
Dates
- Opened
- Jan 8, 1975
- Closing Conference Date
- Jan 8, 1975
- Closed
- Mar 10, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- No
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1275 Budd St, Cincinnati, OH 45203
- Industry
- Not classified in OSHA's inspection record.
Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.
Nov 5, 1974#214612137Nov 5, 1974Planned (H) · Complete scope, Safety#214612137$02 viol.2 violations$0 in penalties
Inspection #214612137
Dates
- Opened
- Nov 5, 1974
- Closing Conference Date
- Nov 5, 1974
- Closed
- Dec 1, 1974
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Not displayed
- Number of Employees
- 16
Violations and Penalties
- Total Violations
- 2
- Violation Types
- 2 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 1270 Budd Street, Cincinnati, OH 45203
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (2 of 2 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.132 Personal Protective Equipment - General Requirements OSHA citation code: 19100132 A01 | Other | 1 | - | $0 | $0 | Dec 10, 1974 | - | - |
| 01002 | 1910.133 Eye and Face Protection OSHA citation code: 19100133 A01 | Other | 1 | - | $0 | $0 | Dec 10, 1974 | - | - |
Oct 11, 1974#214679896Oct 11, 1974Planned (H) · Complete scope, Safety#214679896$5023 viol.23 violations$50 in penalties
Inspection #214679896
Dates
- Opened
- Oct 11, 1974
- Closing Conference Date
- Oct 11, 1974
- Closed
- Mar 10, 1984
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Not displayed
- Number of Employees
- 16
Violations and Penalties
- Total Violations
- 23
- Violation Types
- 23 other-than-serious
- Initial Penalties
- $50
- Penalties on Record
- $50
- Site Address
- 1275 Budd St, Cincinnati, OH 45203
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (16 of 23 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01003 | 1910.22 Walking-Working Surfaces - General Requirements OSHA citation code: 19100022 A01 | Other | 1 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01004 | 1910.141 Sanitation OSHA citation code: 19100141 A04 I | Other | 1 | - | $0 | $0 | Nov 15, 1974 | - | - |
| 01005 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 F03 | Other | 1 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01006 | 1910.309 OSHA citation code: 19100309 A04 | Other | 2 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01007 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 E01 I | Other | 2 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01008 | 1910.219 Mechanical Power-Transmission Apparatus OSHA citation code: 19100219 D01 | Other | 2 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01009 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 D03 I | Other | 1 | - | $0 | $0 | Nov 15, 1974 | - | - |
| 01010 | 1910.157 Portable Fire Extinguishers OSHA citation code: 19100157 A06 | Other | 2 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01011 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 Q05 | Other | 1 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01012 | 1910.37 Maintenance, Safeguards, and Operational Features for Exit Routes OSHA citation code: 19100037 Q08 | Other | 2 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01013 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A03 II | Other | 3 | - | $25 | $25 | Dec 9, 1974 | - | - |
| 01014 | 1910.309 OSHA citation code: 19100309 A 025045 | Other | 1 | - | $0 | $0 | Nov 15, 1974 | - | - |
| 01015 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 B | Other | 1 | - | $0 | $0 | Nov 15, 1974 | - | - |
| 01016 | 1910.106 Flammable Liquids OSHA citation code: 19100106 E02 IVA | Other | 1 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01017 | 1910.106 Flammable Liquids OSHA citation code: 19100106 D02 I | Other | 1 | - | $0 | $0 | Dec 9, 1974 | - | - |
| 01018 | 1910.141 Sanitation OSHA citation code: 19100141 C01 VI | Other | 1 | - | $0 | $0 | Nov 15, 1974 | - | - |
Showing the 16 violations listed first by citation identifier. This inspection has 23 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 1974 to 1975. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.