ITT INDUSTRIAL PROCESS
33 CENTERVILLE ROAD, LANCASTER, PA 17603 · NAICS 332919 Other Metal Valve and Pipe Fitting Manufacturing
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Jan 14, 2010#116211954Jan 14, 2010Planned (H) · Records Only scope, Safety#116211954$00 viol.0 violations$0 in penalties
Inspection #116211954
Dates
- Opened
- Jan 14, 2010
- Closing Conference Date
- Jan 14, 2010
- Closed
- Jan 14, 2010
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 30,000
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 33 Centerville Road, Lancaster, PA 17603
- Industry
- 332611
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jul 15, 2004#112898366Jul 15, 2004Complaint (B) · Partial scope, Safety#112898366$2,4355 viol.5 violations$2,435 in penalties
Inspection #112898366
Dates
- Opened
- Jul 15, 2004
- Closing Conference Date
- Sep 1, 2004
- Closed
- Oct 12, 2004
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 235
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 5
- Violation Types
- 3 serious, 2 other-than-serious
- Initial Penalties
- $3,750
- Penalties on Record
- $2,435
- Site Address
- 33 Centerville Road, Lancaster, PA 17603
- Industry
- 332919 Other Metal Valve and Pipe Fitting Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Violations
Violation list (5 of 5 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 1 | $1,500 | $975 | Sep 29, 2004 | - | - |
| 01002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 G02 III | Serious | 1 | 1 | $1,125 | $730 | Sep 29, 2004 | - | - |
| 01003 | 1910.334 Electrical - Use of Equipment OSHA citation code: 19100334 A02 II | Serious | 1 | 1 | $1,125 | $730 | Oct 21, 2004 | - | - |
| 02001 | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 F | Other | 1 | 2 | $0 | $0 | Sep 29, 2004 | - | - |
| 02002 | 1910.305 Electrical - Wiring Methods, Components, and Equipment OSHA citation code: 19100305 J02 II | Other | 1 | 1 | $0 | $0 | Sep 29, 2004 | - | - |
Sep 28, 1999#300410644Sep 28, 1999Complaint (B) · Partial scope, Safety#300410644$00 viol.0 violations$0 in penalties
Inspection #300410644
Dates
- Opened
- Sep 28, 1999
- Closing Conference Date
- Sep 28, 1999
- Closed
- Sep 28, 1999
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 270
- Related Activity
- 1 complaint
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 33 Centerville Road, Lancaster, PA 17603
- Industry
- 332919 Other Metal Valve and Pipe Fitting Manufacturing
Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.
Jan 3, 1997#116163072Jan 3, 1997Planned (H) · No Inspection scope, Safety#116163072$00 viol.0 violations$0 in penalties
Inspection #116163072
Dates
- Opened
- Jan 3, 1997
- Closing Conference Date
- Jan 3, 1997
- Closed
- Jan 22, 1997
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- Not recorded
Violations and Penalties
- Total Violations
- 0
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- 33 Centerville Road, Lancaster, PA 17603
- Industry
- 332919 Other Metal Valve and Pipe Fitting Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Jun 24, 1996#116157876Jun 24, 1996Planned (H) · Complete scope, Safety#116157876$7,0008 viol.8 violations$7,000 in penalties
Inspection #116157876
Dates
- Opened
- Jun 24, 1996
- Closing Conference Date
- Jun 24, 1996
- Closed
- Aug 7, 1996
Inspection
- Advance Notice
- No
- Owner Type
- Private
- Union Status
- Yes
- Number of Employees
- 318
Violations and Penalties
- Total Violations
- 8
- Violation Types
- 7 serious, 1 other-than-serious
- Initial Penalties
- $12,000
- Penalties on Record
- $7,000
- Site Address
- 33 Centerville Road, Lancaster, PA 17603
- Industry
- 332919 Other Metal Valve and Pipe Fitting Manufacturing
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (8 of 8 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1910.107 Spray Finishing Using Flammable and Combustible Materials OSHA citation code: 19100107 B09 | Serious | 2 | 2 | $1,125 | $650 | Jul 24, 1996 | - | - |
| 01002 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C07 I | Serious | 1 | 6 | $2,625 | $1,500 | Aug 13, 1996 | - | - |
| 01003 | 1910.212 General Requirements for All Machines (Machine Guarding) OSHA citation code: 19100212 A01 | Serious | 1 | 3 | $1,500 | $900 | Aug 13, 1996 | - | - |
| 01004 | 1910.213 Woodworking Machinery Requirements OSHA citation code: 19100213 H04 | Serious | 1 | 1 | $1,125 | $650 | Aug 13, 1996 | - | - |
| 01005 | 1910.215 Abrasive Wheel Machinery OSHA citation code: 19100215 A02 | Serious | 1 | 1 | $1,125 | $650 | Aug 13, 1996 | - | - |
| 01006A | 1910.303 Electrical - General Requirements OSHA citation code: 19100303 G02 I | Serious | 1 | 2 | $4,500 | $2,650 | Jul 21, 1996 | - | - |
| 01006B | 1910.333 Electrical - Selection and Use of Work Practices OSHA citation code: 19100333 A | Serious | 1 | 2 | $0 | $0 | Jul 21, 1996 | - | - |
| 02001 | 1910.147 Control of Hazardous Energy (Lockout/Tagout) OSHA citation code: 19100147 C01 | Other | 1 | 6 | $0 | $0 | Aug 13, 1996 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
5 inspections, 1996 to 2010. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.
Standards cited
Industry comparison
Fabricated Metal Product Manufacturing, 48,574 employers with OSHA inspections. Arithmetic from DOL records.