J A VALENTI ELECTRIC CO INC
OLD RIDGEBURY ROAD, Danbury, CT 06810
Having inspection records is common for businesses in regulated industries. Data and methodology
Inspection records
Mar 31, 1980#10479715Mar 31, 1980Unprogrammed Related (G) · Complete scope, Safety#10479715$014 viol.14 violations$0 in penalties
Inspection #10479715
Dates
- Opened
- Mar 31, 1980
- Closing Conference Date
- Apr 15, 1980
- Closed
- Jul 11, 1980
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 70
Violations and Penalties
- Total Violations
- 14
- Violation Types
- 14 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Old Ridgebury Road Union Carbi, Danbury, CT 06810
- Industry
- Not classified in OSHA's inspection record.
Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.
Violations
Violation list (14 of 14 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.20 General Safety and Health Provisions OSHA citation code: 19260020 B03 | Other | 3 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01002 | 1926.25 Housekeeping OSHA citation code: 19260025 A | Other | 3 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01003 | 1926.25 Housekeeping OSHA citation code: 19260025 B | Other | 1 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01004 | 1926.152 OSHA citation code: 19260152 A01 | Other | 3 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01005 | 1926.200 Accident Prevention Signs and Tags OSHA citation code: 19260200 C01 | Other | 1 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01006 | 1926.250 General Requirements for Storage OSHA citation code: 19260250 A03 | Other | 1 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01007 | 1926.250 General Requirements for Storage OSHA citation code: 19260250 B09 | Other | 1 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01008 | 1926.400 Introduction (Electrical - Construction) OSHA citation code: 19260400 A 040010 | Other | 2 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01009 | 1926.401 OSHA citation code: 19260401 C | Other | 1 | - | $0 | $0 | Jun 2, 1980 | - | - |
| 01010 | 1926.401 OSHA citation code: 19260401 J01 | Other | 9 | - | $0 | $0 | May 24, 1980 | - | - |
| 01011 | 1926.401 OSHA citation code: 19260401 J03 | Other | 1 | - | $0 | $0 | May 24, 1980 | - | - |
| 01012 | 1926.402 Applicability (Electrical - Construction) OSHA citation code: 19260402 A08 | Other | 1 | - | $0 | $0 | May 24, 1980 | - | - |
| 01013 | 1926.402 Applicability (Electrical - Construction) OSHA citation code: 19260402 C01 | Other | 3 | - | $0 | $0 | Jun 9, 1980 | - | - |
| 01014 | 1926.500 Scope, application, and definitions applicable to this subpart OSHA citation code: 19260500 E01 III | Other | 1 | - | $0 | $0 | Jun 2, 1980 | - | - |
Sep 5, 1979#10575231Sep 5, 1979Planned (H) · Complete scope, Safety#10575231$18016 viol.16 violations$180 in penalties
Inspection #10575231
Dates
- Opened
- Sep 5, 1979
- Closing Conference Date
- Sep 12, 1979
- Closed
- Nov 8, 1979
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 52
Violations and Penalties
- Total Violations
- 16
- Violation Types
- 1 serious, 15 other-than-serious
- Initial Penalties
- $180
- Penalties on Record
- $180
- Site Address
- Old Ridgebury Road, Danbury, CT 06810
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (16 of 16 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.651 Excavations - Specific Excavation Requirements OSHA citation code: 19260651 C | Serious | 1 | - | $180 | $180 | Oct 4, 1979 | - | - |
| 02001 | 1926.20 General Safety and Health Provisions OSHA citation code: 19260020 B03 | Other | 3 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02002 | 1926.150 Fire Protection (Construction) OSHA citation code: 19260150 C01 I | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02003 | 1926.250 General Requirements for Storage OSHA citation code: 19260250 A03 | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02004 | 1926.400 Introduction (Electrical - Construction) OSHA citation code: 19260400 A 023050 | Other | 2 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02005 | 1926.400 Introduction (Electrical - Construction) OSHA citation code: 19260400 A 037304 | Other | 2 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02006 | 1926.401 OSHA citation code: 19260401 B | Other | 3 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02007 | 1926.401 OSHA citation code: 19260401 J01 | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02008 | 1926.402 Applicability (Electrical - Construction) OSHA citation code: 19260402 A08 | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02009 | 1926.402 Applicability (Electrical - Construction) OSHA citation code: 19260402 C01 | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02010 | 1926.451 Scaffolding - General Requirements OSHA citation code: 19260451 D04 | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02011 | 1926.500 Scope, application, and definitions applicable to this subpart OSHA citation code: 19260500 B08 | Other | 3 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02012 | 1926.500 Scope, application, and definitions applicable to this subpart OSHA citation code: 19260500 E01 III | Other | 2 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02013 | 1926.500 Scope, application, and definitions applicable to this subpart OSHA citation code: 19260500 E01 IV | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02014 | 1926.601 Motor Vehicles OSHA citation code: 19260601 B02 II | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
| 02015 | 1926.601 Motor Vehicles OSHA citation code: 19260601 B05 | Other | 1 | - | $0 | $0 | Oct 4, 1979 | - | - |
Mar 19, 1979#10573806Mar 19, 1979Planned (H) · Complete scope, Safety#10573806$01 viol.1 violation$0 in penalties
Inspection #10573806
Dates
- Opened
- Mar 19, 1979
- Closing Conference Date
- Mar 19, 1979
- Closed
- May 14, 1979
Inspection
- Advance Notice
- Not recorded
- Owner Type
- Not recorded
- Union Status
- Yes
- Number of Employees
- 3
Violations and Penalties
- Total Violations
- 1
- Violation Types
- 1 other-than-serious
- Initial Penalties
- $0
- Penalties on Record
- $0
- Site Address
- Old Ridgebury Road, Danbury, CT 06810
- Industry
- Not classified in OSHA's inspection record.
Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.
Violations
Violation list (1 of 1 shown)
| Citation | Standard | Type | Instances | Exposed | Initial | Current | Abatement | Contest | Final Order |
|---|---|---|---|---|---|---|---|---|---|
| 01001 | 1926.400 Introduction (Electrical - Construction) OSHA citation code: 19260400 A 011017 | Other | 1 | - | $0 | $0 | Mar 29, 1979 | - | - |
Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records
About these records
A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).
This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.
OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.
OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.
Understanding These Penalties
The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.
3 inspections, 1979 to 1980. Each row is one inspection; point at or tap a row for its dates and totals.
Source: DOL OSHA enforcement data (inspections and violations), linked via activity_nr (exact government key).
Penalty changes: Amounts shown reflect what OSHA's enforcement record publishes. The reason for any change is not stated unless OSHA's record explicitly says so.
Short cases: When a case closed soon after it opened, the closed marker is drawn slightly to the right so both markers stay visible. Each row's card shows the exact dates.