Skip to content
SafetyRecord logoSafetyRecord
J. P. ROTELLA CO. INC.
$2,750
penalties
32
viol.
5
insp.

J. P. ROTELLA CO. INC.

18-20 EAST BARBOUR ST, HALEDON, NJ 07508

Inspections
5
Aug 1984 to May 1989 · 5 safety, 0 health
Violations
32
across 5 inspections
Penalties on record
$2,750
latest amounts in DOL records
By classification
Serious 14Willful 1Repeat 0Other 17

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

May 3, 1989Follow-Up (F) · Partial scope, Safety#17635590$00 viol.

Inspection #17635590

Dates

Opened
May 3, 1989
Closing Conference Date
May 3, 1989
Closed
May 3, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
20 East Barbour Street, Haledon, NJ 07508
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Mar 15, 1989Follow-Up (F) · Partial scope, Safety#17641044$00 viol.

Inspection #17641044

Dates

Opened
Mar 15, 1989
Closing Conference Date
Mar 15, 1989
Closed
Apr 10, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
20 E. Barbour Street, Haledon, NJ 07508
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Nov 18, 1988Monitoring (D) · Partial scope, Safety#756395$00 viol.

Inspection #756395

Dates

Opened
Nov 18, 1988
Closing Conference Date
Nov 18, 1988
Closed
Nov 21, 1988

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
20 E. Barbour Street, Haledon, NJ 07508
Industry
Not classified in OSHA's inspection record.

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Jun 22, 1988Planned (H) · Complete scope, Safety#100707504$2,75028 viol.

Inspection #100707504

Dates

Opened
Jun 22, 1988
Closing Conference Date
Jul 5, 1988
Closed
May 3, 1989

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
17

Violations and Penalties

Total Violations
28
Violation Types
14 serious, 1 willful, 13 other-than-serious
Initial Penalties
$6,700
Penalties on Record
$2,750
Site Address
20 E. Barbour Street, Haledon, NJ 07508
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (10 of 28 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.36
OSHA citation code: 19100036 B04
Serious15$150$75Oct 25, 1988--
010021910.37
OSHA citation code: 19100037 H01
Serious26$150$75Oct 25, 1988--
010031910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious21$100$100Jan 26, 1989--
010041910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A04
Serious11$100$100Oct 25, 1988--
01005A1910.217
Mechanical Power Presses
OSHA citation code: 19100217 B03 I
Serious22$250$100Apr 26, 1989--
01005B1910.217
Mechanical Power Presses
OSHA citation code: 19100217 E01 I
Serious206$0$0Jan 26, 1989--
010061910.217
Mechanical Power Presses
OSHA citation code: 19100217 B04 I
Serious125$250$100Feb 26, 1989--
010071910.217
Mechanical Power Presses
OSHA citation code: 19100217 B08 III
Serious136$250$100Jan 26, 1989--
010081910.217
Mechanical Power Presses
OSHA citation code: 19100217 D05
Serious63$250$100Mar 26, 1989--
010091910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 B01
Serious156$200$100Apr 26, 1989--

Showing the 10 violations listed first by citation identifier. This inspection has 28 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Aug 13, 1984Planned (H) · Complete scope, Safety#1022458$04 viol.

Inspection #1022458

Dates

Opened
Aug 13, 1984
Closing Conference Date
Aug 13, 1984
Closed
Sep 2, 1984

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
14

Violations and Penalties

Total Violations
4
Violation Types
4 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
18-20 East Barbour St, Haledon, NJ 07508
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.215
Abrasive Wheel Machinery
OSHA citation code: 19100215 B09
Other11$0$0Sep 4, 1984--
01002A1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 D01
Other33$0$0Sep 4, 1984--
01002B1910.219
Mechanical Power-Transmission Apparatus
OSHA citation code: 19100219 E01 I
Other33$0$0Sep 4, 1984--
010031910.305
Wiring methods, components, and equipment for general use
OSHA citation code: 19100305 B02
Other11$0$0Aug 27, 1984--
Inspections 1 to 5 of 5, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.217Mechanical Power Presses9 citations · $1,900
1910.219Mechanical Power-Transmission Apparatus5 citations · $300
1910.1200Hazard Communication4 citations · $0

Other inspected employers in HALEDON, NJ

All employers in HALEDON →