Skip to content
SafetyRecord logoSafetyRecord
JOHN ROCCHIO CORP
$37,550
penalties
7
viol.
3
insp.

JOHN ROCCHIO CORP

RT 117, COVENTRY, RI 02816NAICS 237110 Water and Sewer Line and Related Structures Construction

Inspections
3
Jul 2003 to Apr 2004 · 3 safety, 0 health
Violations
7
across 3 inspections
Penalties on record
$37,550
latest amounts in DOL records
By classification
Serious 3Willful 1Repeat 3Other 0

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 6, 2004Planned (H) · Complete scope, Safety#304996051$00 viol.

Inspection #304996051

Dates

Opened
Apr 6, 2004
Closing Conference Date
Apr 6, 2004
Closed
Apr 13, 2004

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
4

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Rt 117, Coventry, RI 02816
Industry
237110 Water and Sewer Line and Related Structures Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Oct 14, 2003Complaint (B) · Complete scope, Safety#304994072$31,5504 viol.

Inspection #304994072

Dates

Opened
Oct 14, 2003
Closing Conference Date
Oct 23, 2003
Contested
Nov 25, 2003
Final Order
Jun 30, 2004
Closed
Mar 31, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
4
Related Activity
1 complaint

Violations and Penalties

Total Violations
4
Violation Types
2 serious, 1 willful, 1 repeat
Initial Penalties
$63,100
Penalties on Record
$31,550
Site Address
Rt 117, Coventry, RI 02816
Industry
237110 Water and Sewer Line and Related Structures Construction

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Violations

Violation list (4 of 4 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.652
Excavations - Protection of Employees
OSHA citation code: 19260652 G01 II
Serious12$1,500$750Nov 18, 2003Nov 25, 2003Jun 30, 2004
010021926.652
Excavations - Protection of Employees
OSHA citation code: 19260652 G01 III
Serious11$4,200$2,100Nov 18, 2003Nov 25, 2003Jun 30, 2004
020011926.652
Excavations - Protection of Employees
OSHA citation code: 19260652 A01
Willful22$49,000$24,500Nov 18, 2003Nov 25, 2003Jun 30, 2004
030011926.651
Excavations - Specific Excavation Requirements
OSHA citation code: 19260651 K02
Repeat12$8,400$4,200Nov 13, 2004Nov 25, 2003Jun 30, 2004
Jul 22, 2003Planned (H) · Complete scope, Safety#304993132$6,0003 viol.

Inspection #304993132

Dates

Opened
Jul 22, 2003
Closing Conference Date
Jul 22, 2003
Contested
Sep 25, 2003
Final Order
Aug 13, 2004
Closed
Mar 31, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
7

Violations and Penalties

Total Violations
3
Violation Types
1 serious, 2 repeat
Initial Penalties
$12,000
Penalties on Record
$6,000
Site Address
Rt 117, Coventry, RI 02816
Industry
237110 Water and Sewer Line and Related Structures Construction

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.416
Electrical - Safety Requirements (Construction)
OSHA citation code: 19260416 A01
Serious53$3,000$1,500Sep 3, 2003Sep 25, 2003Aug 13, 2004
020011926.651
Excavations - Specific Excavation Requirements
OSHA citation code: 19260651 C02
Repeat12$3,000$1,500Sep 2, 2003Sep 25, 2003Aug 13, 2004
020021926.651
Excavations - Specific Excavation Requirements
OSHA citation code: 19260651 K02
Repeat13$6,000$3,000Sep 4, 2003Sep 25, 2003Aug 13, 2004
Inspections 1 to 3 of 3, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.651Excavations - Specific Excavation Requirements3 citations · $8,700
1926.652Excavations - Protection of Employees3 citations · $27,350
1926.416Electrical - Safety Requirements (Construction)1 citation · $1,500

Industry comparison

Violations per inspection
This employer2.3
Industry average1.6
Penalties per inspection
This employer$12,517
Industry average$2,255

Heavy and Civil Engineering Construction, 70,282 employers with OSHA inspections. Arithmetic from DOL records.

BLS 2024 survey: water and sewer line and related structures construction reported 1.9 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 9.4%; NAICS 23711 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in COVENTRY, RI

All employers in COVENTRY →