Skip to content
SafetyRecord logoSafetyRecord
JOHNSON CONTROLS BATTERY GROUP, INC.
$277,000
penalties
47
viol.
10
insp.

JOHNSON CONTROLS BATTERY GROUP, INC.

2701 JOHNSON CONTROLS DRIVE, KERNERSVILLE, NC 27284NAICS 335911 Storage Battery Manufacturing

Inspections
10
Jul 2010 to Apr 2018 · 5 safety, 5 health
Violations
47
across 10 inspections
Penalties on record
$277,000
latest amounts in DOL records
By classification
Serious 36Willful 0Repeat 0Other 11

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Apr 9, 2018Complaint (B) · Partial scope, Health#343079687$00 viol.

Inspection #343079687

Dates

Opened
Apr 9, 2018
Closing Conference Date
Apr 18, 2018
Closed
Jun 15, 2018

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
380
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2701johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Aug 8, 2016Referral (C) · Partial scope, Health#341653459$00 viol.

Inspection #341653459

Dates

Opened
Aug 8, 2016
Closing Conference Date
Oct 17, 2016
Closed
Oct 17, 2016

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
355
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Aug 11, 2015Referral (C) · Partial scope, Safety#318002870$2,0001 viol.

Inspection #318002870

Dates

Opened
Aug 11, 2015
Closing Conference Date
Aug 26, 2015
Final Order
Sep 28, 2015
Closed
Oct 16, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
355
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$2,250
Penalties on Record
$2,000
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A02
Other14$2,250$2,000Sep 8, 2015-Sep 28, 2015
Apr 9, 2015Referral (C) · Partial scope, Safety#317984300$00 viol.

Inspection #317984300

Dates

Opened
Apr 9, 2015
Closing Conference Date
Apr 21, 2015
Closed
Apr 27, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
350
Related Activity
1 referral

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Jan 20, 2015Referral (C) · Partial scope, Safety#317944296$01 viol.

Inspection #317944296

Dates

Opened
Jan 20, 2015
Closing Conference Date
Apr 1, 2015
Closed
Jun 4, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
350
Related Activity
1 referral

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Referral Inspection: This inspection record is categorized as a referral inspection in the DOL OSHA enforcement data. Referral inspections can result from another agency, another OSHA activity, or another source referring a potential hazard to OSHA.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 G01 IVA
Other15$0$0Apr 6, 2015--
Feb 5, 2014Complaint (B) · Partial scope, Health#317553220$00 viol.

Inspection #317553220

Dates

Opened
Feb 5, 2014
Closing Conference Date
Apr 10, 2014
Closed
Apr 10, 2014

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
320
Related Activity
1 complaint

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Complaint Inspection: This inspection record is categorized as a complaint inspection in the DOL OSHA enforcement data. OSHA can open complaint-driven inspections after receiving safety or health complaints from workers or their representatives.

Sep 13, 2011Monitoring (D) · Complete scope, Health#315975045$00 viol.

Inspection #315975045

Dates

Opened
Sep 13, 2011
Closing Conference Date
Sep 13, 2011
Closed
Oct 26, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
320

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Sep 13, 2011Monitoring (D) · Partial scope, Safety#315858647$00 viol.

Inspection #315858647

Dates

Opened
Sep 13, 2011
Closing Conference Date
Sep 13, 2011
Closed
Dec 14, 2011

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
343

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Monitoring Inspection: This inspection record is categorized as a monitoring inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Oct 26, 2010Programmed Related (I) · Complete scope, Safety#314807124$91,40030 viol.

Inspection #314807124

Dates

Opened
Oct 26, 2010
Closing Conference Date
Apr 20, 2011
Contested
Jun 8, 2011
Final Order
Jan 5, 2012
Closed
Mar 27, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
250

Violations and Penalties

Total Violations
30
Violation Types
22 serious, 8 other-than-serious
Initial Penalties
$113,500
Penalties on Record
$91,400
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Programmed Related Inspection: This inspection record is categorized as a programmed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (5 of 30 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.212
General Requirements for All Machines (Machine Guarding)
OSHA citation code: 19100212 A01
Serious215$14,000$9,000Apr 26, 2011Jun 8, 2011Jan 5, 2012
010021910.305
Electrical - Wiring Methods, Components, and Equipment
OSHA citation code: 19100305 B02
Serious5230$10,000$6,500Apr 26, 2011Jun 8, 2011Jan 5, 2012
02001A1910.22
Walking-Working Surfaces - General Requirements
OSHA citation code: 19100022 A01
Serious3120$3,000$2,300Apr 26, 2011Jun 8, 2011Jan 5, 2012
02001B1910.141
Sanitation
OSHA citation code: 19100141 A03 I
Serious3120$0$0Apr 26, 2011Jun 8, 2011Jan 5, 2012
020021910.132
Personal Protective Equipment - General Requirements
OSHA citation code: 19100132 E
Serious24$3,000$2,300Apr 26, 2011Jun 8, 2011Jan 5, 2012

Showing the 5 violations listed first by citation identifier. This inspection has 30 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Jul 12, 2010Planned (H) · Partial scope, Health#314705856$183,60015 viol.

Inspection #314705856

Dates

Opened
Jul 12, 2010
Closing Conference Date
Jan 7, 2011
Contested
Mar 3, 2011
Final Order
Jan 5, 2012
Closed
Mar 12, 2012

Inspection

Advance Notice
No
Owner Type
Private
Union Status
Yes
Number of Employees
275

Violations and Penalties

Total Violations
15
Violation Types
14 serious, 1 other-than-serious
Initial Penalties
$331,000
Penalties on Record
$183,600
Site Address
2701 Johnson Controls Drive, Kernersville, NC 27284
Industry
335911 Storage Battery Manufacturing

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (5 of 15 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1025
Lead
OSHA citation code: 19101025 D06 II
Serious14200$70,000$47,000Jan 18, 2011Mar 3, 2011Jan 5, 2012
010021910.1025
Lead
OSHA citation code: 19101025 D06 III
Serious12200$70,000$47,000Jan 18, 2011Mar 3, 2011Jan 5, 2012
010031910.1025
Lead
OSHA citation code: 19101025 E01 I
Serious3200$70,000$47,000Feb 24, 2011Mar 3, 2011Jan 5, 2012
020011904.4
Recording Criteria
OSHA citation code: 19040004 A
Other2397$70,000$8,100Feb 24, 2011Mar 3, 2011Jan 5, 2012
030019501.2901Serious11$5,000$4,000Jan 18, 2011Mar 3, 2011Jan 5, 2012

Showing the 5 violations listed first by citation identifier. This inspection has 15 total violations documented in the U.S. Department of Labor OSHA enforcement database. The complete violation list is available at enforcedata.dol.gov.

Inspections 1 to 10 of 10, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1910.1025Lead7 citations · $154,300
1910.305Electrical - Wiring Methods, Components, and Equipment7 citations · $17,500
1910.303Electrical - General Requirements6 citations · $12,000

Industry comparison

Violations per inspection
This employer4.7
Industry average3.1
Penalties per inspection
This employer$27,700
Industry average$2,448

Electrical Equipment, Appliance, and Component Manufacturing, 4,465 employers with OSHA inspections. Arithmetic from DOL records.

Other inspected employers in KERNERSVILLE, NC

All employers in KERNERSVILLE →