Skip to content
SafetyRecord logoSafetyRecord
K L S ELECTRIC, INC.
$900
penalties
12
viol.
9
insp.

K L S ELECTRIC, INC.

8151 EAST SPEEDWAY, TUCSON, AZ 85710

Inspections
9
Oct 1997 to Nov 2014 · 7 safety, 2 health
Violations
12
across 9 inspections
Penalties on record
$900
latest amounts in DOL records
By classification
Serious 2Willful 0Repeat 0Other 10

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Nov 17, 2014Planned (H) · Complete scope, Safety#340087998$01 viol.

Inspection #340087998

Dates

Opened
Nov 17, 2014
Closing Conference Date
Nov 17, 2014
Final Order
Jan 10, 2015
Closed
Jan 10, 2015

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
6

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
701 W. Wetmore Rd., Tucson, AZ 85705
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 II E
Other16$0$0-Jan 10, 2015
Nov 1, 2007Planned (H) · Complete scope, Safety#311613624$00 viol.

Inspection #311613624

Dates

Opened
Nov 1, 2007
Closing Conference Date
Nov 1, 2007
Closed
Nov 5, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
10701 E. Mary Ann Cleveland Way, Tucson, AZ 85747
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Mar 14, 2007Planned (H) · Complete scope, Safety#310979414$03 viol.

Inspection #310979414

Dates

Opened
Mar 14, 2007
Closing Conference Date
Mar 14, 2007
Closed
Jun 19, 2007

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
7

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
8500 Continental Reserve Loop, Tucson, AZ 85653
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIB
Other47$0$0Apr 28, 2007--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 IIF
Other17$0$0Apr 28, 2007--
010031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 III
Other17$0$0Apr 28, 2007--
Jul 17, 2006Planned (H) · Complete scope, Safety#310282124$00 viol.

Inspection #310282124

Dates

Opened
Jul 17, 2006
Closing Conference Date
Jul 17, 2006
Closed
Jul 17, 2006

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
4

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
7350 East Speedway, Tucson, AZ 85710
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Apr 20, 2005Planned (H) · Complete scope, Safety#309034015$02 viol.

Inspection #309034015

Dates

Opened
Apr 20, 2005
Closing Conference Date
Apr 20, 2005
Closed
Jul 12, 2005

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
12

Violations and Penalties

Total Violations
2
Violation Types
2 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
9075 South Houghton Road, Tucson, AZ 85747
Industry
238210 Electrical Contractors and Other Wiring Installation Contractors

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011910.1200
Hazard Communication
OSHA citation code: 19101200 E01 I
Other18$0$0Jun 23, 2005--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 G02 IV
Other18$0$0Jun 5, 2005--
Oct 5, 2000Planned (H) · Partial scope, Safety#303996565$03 viol.

Inspection #303996565

Dates

Opened
Oct 5, 2000
Closing Conference Date
Oct 5, 2000
Closed
Nov 22, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
25

Violations and Penalties

Total Violations
3
Violation Types
3 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
1255 N. Stone, Tucson, AZ 85705
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 H
Other11$0$0Nov 28, 2000--
010021926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 A02 III
Other11$0$0Nov 28, 2000--
010031926.405
Electrical - Wiring Methods (Construction)
OSHA citation code: 19260405 B01
Other11$0$0Nov 28, 2000--
Jun 21, 2000Unprogrammed Related (G) · Partial scope, Safety#303633473$01 viol.

Inspection #303633473

Dates

Opened
Jun 21, 2000
Closing Conference Date
Jun 21, 2000
Closed
Jul 27, 2000

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
1

Violations and Penalties

Total Violations
1
Violation Types
1 other-than-serious
Initial Penalties
$0
Penalties on Record
$0
Site Address
3645 East Pima Road, Tucson, AZ 85716
Industry
Not classified in OSHA's inspection record.

Unprogrammed Related Inspection: This inspection record is categorized as an unprogrammed related inspection in the DOL OSHA enforcement data. The public DOL category label is preserved here without adding extra interpretation beyond the government label.

Violations

Violation list (1 of 1 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.403
Electrical - General Requirements (Construction)
OSHA citation code: 19260403 B02
Other11$0$0Jul 17, 2000--
Feb 3, 1998Follow-Up (F) · Partial scope, Health#126999754$00 viol.

Inspection #126999754

Dates

Opened
Feb 3, 1998
Closing Conference Date
Feb 3, 1998
Closed
Feb 3, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
8151 East Speedway, Tucson, AZ 85710
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Oct 22, 1997Planned (H) · Partial scope, Health#126998574$9002 viol.

Inspection #126998574

Dates

Opened
Oct 22, 1997
Closing Conference Date
Oct 22, 1997
Closed
Feb 3, 1998

Inspection

Advance Notice
No
Owner Type
Private
Union Status
No
Number of Employees
5

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$1,200
Penalties on Record
$900
Site Address
8151 East Speedway, Tucson, AZ 85710
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.501
Fall Protection - Duty to Have Fall Protection
OSHA citation code: 19260501 B14
Serious14$600$450Nov 22, 1997--
010021926.503
Fall Protection - Training Requirements
OSHA citation code: 19260503 A01
Serious14$600$450Nov 22, 1997--
Inspections 1 to 9 of 9, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.405Electrical - Wiring Methods (Construction)7 citations · $0
1926.403Electrical - General Requirements (Construction)2 citations · $0
1910.1200Hazard Communication1 citation · $0

Industry comparison

BLS 2024 survey: electrical contractors and other wiring installation contractors reported 1.8 injuries and illnesses per 100 full-time workers (total recordable cases, national, private industry; relative standard error 5.7%; NAICS 23821 level). This is an industry-wide average from a federal survey, not a measurement of this establishment. Source

Other inspected employers in TUCSON, AZ

All employers in TUCSON →