Skip to content
SafetyRecord logoSafetyRecord
KARAM CONSTRUCTION CORP
$1,870
penalties
13
viol.
6
insp.

KARAM CONSTRUCTION CORP

1060 CLARKSON AVENUE, New York -Richmond, NY 11212

Inspections
6
Aug 1979 to Jan 1984 · 6 safety, 0 health
Violations
13
across 6 inspections
Penalties on record
$1,870
latest amounts in DOL records
By classification
Serious 8Willful 0Repeat 0Other 5

Having inspection records is common for businesses in regulated industries. Data and methodology

Inspection records

Jan 18, 1984Planned (H) · Complete scope, Safety#11804226$00 viol.

Inspection #11804226

Dates

Opened
Jan 18, 1984
Closing Conference Date
Jan 18, 1984
Closed
Jan 31, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
No
Number of Employees
2

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
Red Hook Bathouse & Pool, New York -richmond, NY 11231
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Sep 7, 1983Planned (H) · Complete scope, Safety#11868262$2802 viol.

Inspection #11868262

Dates

Opened
Sep 7, 1983
Closing Conference Date
Sep 8, 1983
Closed
Oct 25, 1983

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
100
Related Activity
1 referral

Violations and Penalties

Total Violations
2
Violation Types
2 serious
Initial Penalties
$560
Penalties on Record
$280
Site Address
107 12 To 20 Northern Blvd, New York -richmond, NY 11369
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (2 of 2 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Serious1-$280$140Oct 4, 1983--
010021926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B02
Serious1-$280$140Oct 4, 1983--
Jun 23, 1982Planned (H) · Complete scope, Safety#11723939$00 viol.

Inspection #11723939

Dates

Opened
Jun 23, 1982
Closing Conference Date
Jun 23, 1982
Closed
Jun 24, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
20

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
160 West 116th St, New York -richmond, NY 10026
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Nov 29, 1979Planned (H) · Partial scope, Safety#11684834$2703 viol.

Inspection #11684834

Dates

Opened
Nov 29, 1979
Closing Conference Date
Dec 4, 1979
Contested
Dec 15, 1979
Closed
Jul 8, 1980

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
15

Violations and Penalties

Total Violations
3
Violation Types
3 serious
Initial Penalties
$270
Penalties on Record
$270
Site Address
1060 Clarkson Avenue, New York -richmond, NY 11212
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (3 of 3 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.28
Personal Protective Equipment
OSHA citation code: 19260028 A
Serious1-$90$90Dec 10, 1979Dec 15, 1979-
010021926.100
Head protection
OSHA citation code: 19260100 A
Serious1-$90$90Dec 10, 1979Dec 15, 1979-
010031926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 A13
Serious1-$90$90Dec 12, 1979Dec 15, 1979-
Aug 30, 1979Follow-Up (F) · Complete scope, Safety#12123568$00 viol.

Inspection #12123568

Dates

Opened
Aug 30, 1979
Closing Conference Date
Aug 30, 1979
Closed
Mar 10, 1984

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
6

Violations and Penalties

Total Violations
0
Initial Penalties
$0
Penalties on Record
$0
Site Address
E180 St & Honeywell Ave, New York -richmond, NY 10460
Industry
Not classified in OSHA's inspection record.

Follow-Up Inspection: This inspection record is categorized as a follow-up inspection in the DOL OSHA enforcement data. Follow-up inspections are used by OSHA after earlier enforcement activity and can be used to check later compliance status.

Aug 6, 1979Planned (H) · Complete scope, Safety#12123329$1,3208 viol.

Inspection #12123329

Dates

Opened
Aug 6, 1979
Closing Conference Date
Aug 8, 1979
Contested
Sep 15, 1979
Closed
Jan 11, 1982

Inspection

Advance Notice
Not recorded
Owner Type
Not recorded
Union Status
Yes
Number of Employees
45

Violations and Penalties

Total Violations
8
Violation Types
3 serious, 5 other-than-serious
Initial Penalties
$1,320
Penalties on Record
$1,320
Site Address
E180 St & Honeywell Ave, New York -richmond, NY 10460
Industry
Not classified in OSHA's inspection record.

Planned Inspection: This inspection record is categorized as a planned inspection in the DOL OSHA enforcement data. Planned inspections are part of OSHA's scheduled enforcement activity rather than being opened directly from a complaint or reported incident at that worksite.

Violations

Violation list (8 of 8 shown)
CitationStandardTypeInstancesExposedInitialCurrentAbatementContestFinal Order
010011926.451
Scaffolding - General Requirements
OSHA citation code: 19260451 D10
Serious1-$420$420Aug 18, 1979Sep 15, 1979-
010021926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 B01
Serious1-$480$480Aug 18, 1979Sep 15, 1979-
010031926.500
Scope, application, and definitions applicable to this subpart
OSHA citation code: 19260500 D01
Serious2-$420$420Aug 18, 1979Sep 15, 1979-
020011926.100
Head protection
OSHA citation code: 19260100 A
Other3-$0$0Aug 18, 1979Sep 15, 1979-
020021926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B01 II
Other1-$0$0Aug 18, 1979Sep 15, 1979-
020031926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B02
Other1-$0$0Aug 18, 1979Sep 15, 1979-
020041926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B08
Other2-$0$0Aug 18, 1979Sep 15, 1979-
020051926.552
Material Hoists, Personnel Hoists, and Elevators
OSHA citation code: 19260552 B08
Other2-$0$0Aug 18, 1979Sep 15, 1979-
Inspections 1 to 6 of 6, newest first

Penalty amounts may differ from final amounts after settlement or judicial review. How to read these records

About these records

A company page groups inspections with the same normalized employer name, city and state; it is not a legal-entity identifier (how pages are grouped).

This page displays public OSHA enforcement data. Status text follows the DOL inspection record first and may include citation-level context when the inspection feed and citation records are out of sync. Penalty amounts shown reflect the latest penalty amounts on record in the DOL database and may differ from initial assessments or final amounts. This is not an official OSHA resource.

OSHA's public enforcement data does not publish a "guilty" or "not guilty" field for inspections. The closest outcome fields available are the citation counts, penalty amounts, contest dates, final-order dates, and the inspection close date shown on this page. How to interpret these status fields. How initial and current penalties are recorded.

OSHA may publish multiple citation rows in the same inspection with the same standard and penalty fields. Separate rows can still differ in OSHA metadata such as citation identifier, recorded instance count, exposed workers, or gravity value. Contest and Final Order columns show citation-level dates from OSHA's enforcement record. A dash means OSHA's record does not currently show that activity for the citation.

Understanding These Penalties

The maximum penalty for a serious violation in 2025 is $16,550 per violation. For willful violations, the range is $11,823 to $165,514. The current penalty column shows the latest amount on record in OSHA's database for each citation. When the current penalty differs from the initial penalty, OSHA's records show that the amount changed during the enforcement process, but this page does not determine the specific reason for each change. Penalty amounts are set by OSHA and adjusted annually for inflation.

Standards cited

1926.552Material Hoists, Personnel Hoists, and Elevators5 citations · $140
1926.451Scaffolding - General Requirements3 citations · $650
1926.100Head protection2 citations · $90

Other inspected employers in New York -Richmond, NY

All employers in New York -Richmond →